A Digital Prism Wavefront Sensor for Ground-Based Astronomical Image Correction

Author(s):  
Byron Engler ◽  
Steve Weddell ◽  
Richard Clare
1988 ◽  
Author(s):  
J. G. Allen ◽  
A. Jankevics ◽  
D. Wormell ◽  
L. Schmutz

2020 ◽  
Vol 20 ◽  
pp. 225-245
Author(s):  
Hye Won Lee ◽  
Min Je Kim ◽  
Ju Chan Park ◽  
Gui Young Son ◽  
Mi Young Lee

Author(s):  
Takasuke Nagai ◽  
Munekazu Date ◽  
Shinya Shimizu ◽  
Hideaki Kimata

Author(s):  
G. K. Krasin ◽  
N. G. Stsepuro ◽  
M. S. Kovalev ◽  
E. Yu. Zlokazov
Keyword(s):  

2012 ◽  
Vol 182-183 ◽  
pp. 1751-1755
Author(s):  
Xi Feng Zheng ◽  
Feng Chang

For the purposes of correcting the LED display image, a method based on computer simulation is proposed. First, the development of the LED display panel is introduced. Second, analyze the causes of the problem which image in LED display panel has serious high non-uniformity, and introduce the existed correction techniques which are used to reduce the non-uniformity of LED display image. Simultaneously, point out the ground for shortcomings of these techniques. Third, describe the principle of correction method based on computer simulation detail from two steps, which are the luminous collection and luminous copulation. Forth, describe the realization steps of this method in accordance with the third step. Finally, this method is supplied in a LED display panel, whose resolution is 640×480. Experimental results show that this method is able to reduce the non-uniformity of images from 11.06% to 0.98%..


Author(s):  
Yinhao Pan ◽  
Ningbo Chen ◽  
Liangjian Liu ◽  
Chengbo Liu ◽  
Zhiqiang Xu ◽  
...  

AbstractPhotoacoustic microscopy is an in vivo imaging technology based on the photoacoustic effect. It is widely used in various biomedical studies because it can provide high-resolution images while being label-free, safe, and harmless to biological tissue. Polygon-scanning is an effective scanning method in photoacoustic microscopy that can realize fast imaging of biological tissue with a large field of view. However, in polygon-scanning, fluctuations of the rotating motor speed and the geometric error of the rotating mirror cause image distortions, which seriously affect the photoacoustic-microscopy imaging quality. To improve the image quality of photoacoustic microscopy using polygon-scanning, an image correction method is proposed based on accurate ultrasound positioning. In this method, the photoacoustic and ultrasound imaging data of the sample are simultaneously obtained, and the angle information of each mirror used in the polygon-scanning is extracted from the ultrasonic data to correct the photoacoustic images. Experimental results show that the proposed method can significantly reduce image distortions in photoacoustic microscopy, with the image dislocation offset decreasing from 24.774 to 10.365 μm.


2002 ◽  
Author(s):  
Volker Westphal ◽  
Sunita Radhakrishnan ◽  
Andrew M. Rollins ◽  
Joseph A. Izatt

Sign in / Sign up

Export Citation Format

Share Document