Comparative study of partial volume correction methods in small animal positron emission tomography (PET) of the rat brain

Author(s):  
Wencke Lehnert ◽  
Marie-Claude Gregoire ◽  
Anthonin Reilhac ◽  
Steven R. Meikle
2009 ◽  
Vol 36 (7) ◽  
pp. 3040-3049 ◽  
Author(s):  
Elisabetta De Bernardi ◽  
Elena Faggiano ◽  
Felicia Zito ◽  
Paolo Gerundini ◽  
Giuseppe Baselli

2016 ◽  
Vol 61 (22) ◽  
pp. 7975-7993 ◽  
Author(s):  
Benjamin A Thomas ◽  
Vesna Cuplov ◽  
Alexandre Bousse ◽  
Adriana Mendes ◽  
Kris Thielemans ◽  
...  

2020 ◽  
Vol 13 (4) ◽  
pp. 348-357
Author(s):  
Keisuke Matsubara ◽  
◽  
Masanobu Ibaraki ◽  
Miho Shidahara ◽  
Toshibumi Kinoshita

AbstractImprecise registration between positron emission tomography (PET) and anatomical magnetic resonance (MR) images is a critical source of error in MR imaging-guided partial volume correction (MR-PVC). Here, we propose a novel framework for image registration and partial volume correction, which we term PVC-optimized registration (PoR), to address imprecise registration. The PoR framework iterates PVC and registration between uncorrected PET and smoothed PV-corrected images to obtain precise registration. We applied PoR to the [11C]PiB PET data of 92 participants obtained from the Alzheimer’s Disease Neuroimaging Initiative database and compared the registration results, PV-corrected standardized uptake value (SUV) and its ratio to the cerebellum (SUVR), and intra-region coefficient of variation (CoV) between PoR and conventional registration. Significant differences in registration of as much as 2.74 mm and 3.02° were observed between the two methods (effect size <  − 0.8 or > 0.8), which resulted in considerable SUVR differences throughout the brain, reaching a maximal difference of 62.3% in the sensory motor cortex. Intra-region CoV was significantly reduced using the PoR throughout the brain. These results suggest that PoR reduces error as a result of imprecise registration in PVC and is a useful method for accurately quantifying the amyloid burden in PET.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Mike Sattarivand ◽  
Jennifer Armstrong ◽  
Gregory M. Szilagyi ◽  
Maggie Kusano ◽  
Ian Poon ◽  
...  

Background/Purpose. Limited spatial resolution of positron emission tomography (PET) requires partial volume correction (PVC). Region-based PVC methods are based on geometric transfer matrix implemented either in image-space (GTM) or sinogram-space (GTMo), both with similar performance. Although GTMo is slower, it more closely simulates the 3D PET image acquisition, accounts for local variations of point spread function, and can be implemented for iterative reconstructions. A recent image-based symmetric GTM (sGTM) has shown improvement in noise characteristics and robustness to misregistration over GTM. This study implements the sGTM method in sinogram space (sGTMo), validates it, and evaluates its performance. Methods. Two 3D sphere and brain digital phantoms and a physical sphere phantom were used. All four region-based PVC methods (GTM, GTMo, sGTM, and sGTMo) were implemented and their performance was evaluated. Results. All four PVC methods had similar accuracies. Both noise propagation and robustness of the sGTMo method were similar to those of sGTM method while they were better than those of GTMo method especially for smaller objects. Conclusion. The sGTMo was implemented and validated. The performance of the sGTMo in terms of noise characteristics and robustness to misregistration is similar to that of the sGTM method and improved compared to the GTMo method.