Justifying and planning an energy monitoring system in an existing plant

Author(s):  
A.P. Stublen ◽  
C.M. Wellman ◽  
S.A. Kell ◽  
T.W. Langston
Author(s):  
Mopuri Deepika ◽  
Merugu Kavitha ◽  
N. S. Kalyan Chakravarthy ◽  
J. Srinivas Rao ◽  
D. Mohan Reddy ◽  
...  

2021 ◽  
Vol 17 (3) ◽  
pp. 1-20
Author(s):  
Vanh Khuyen Nguyen ◽  
Wei Emma Zhang ◽  
Adnan Mahmood

Intrusive Load Monitoring (ILM) is a method to measure and collect the energy consumption data of individual appliances via smart plugs or smart sockets. A major challenge of ILM is automatic appliance identification, in which the system is able to determine automatically a label of the active appliance connected to the smart device. Existing ILM techniques depend on labels input by end-users and are usually under the supervised learning scheme. However, in reality, end-users labeling is laboriously rendering insufficient training data to fit the supervised learning models. In this work, we propose a semi-supervised learning (SSL) method that leverages rich signals from the unlabeled dataset and jointly learns the classification loss for the labeled dataset and the consistency training loss for unlabeled dataset. The samples fit into consistency learning are generated by a transformation that is built upon weighted versions of DTW Barycenter Averaging algorithm. The work is inspired by two recent advanced works in SSL in computer vision and combines the advantages of the two. We evaluate our method on the dataset collected from our developed Internet-of-Things based energy monitoring system in a smart home environment. We also examine the method’s performances on 10 benchmark datasets. As a result, the proposed method outperforms other methods on our smart appliance datasets and most of the benchmarks datasets, while it shows competitive results on the rest datasets.


2013 ◽  
Vol 66 ◽  
pp. 41-48 ◽  
Author(s):  
Liang Zhao ◽  
Ji-li Zhang ◽  
Ruo-bing Liang

2014 ◽  
Vol 521 ◽  
pp. 435-439
Author(s):  
Cheng Hao Han ◽  
Xiang Tong Wang ◽  
Hao Li ◽  
Ying Qin ◽  
Dong Yu Liu ◽  
...  

To solve the problems of bulky, high cost and difficult maintenance existing in the electric parameters monitoring system currently, a new electric energy monitoring system is designed. In the system, MAXQ3180 chip can collect the voltage, current, power factor, harmonic and other parameters of the load. Then the relevant data can be collected and sent to AT89S52 microcontroller through SPI bus to saving and manipulating. Meanwhile, to achieve the goal of decentralized control and centralized management, the system can exchange the relevant data with upper computer by CAN bus communication mode. Then the accurate measurement and intelligent management of the electric parameter can be achieved.


2018 ◽  
Vol 42 ◽  
pp. 01003
Author(s):  
Sentagi Sesotya Utami ◽  
Faridah ◽  
Na’im A. Azizi ◽  
Erlin Kencanawati ◽  
M. Akbar Tanjung ◽  
...  

Current studies conducted by JICA, AMPRI and IFC-World Bank, reported that large commercial buildings in Indonesia are not energy and water efficient. One of the cause is the lack of regulation. Meanwhile, effective regulations to reduce energy and water consumption are the concern mostly in a new building to obtain a building permit. This strategy is understandable as retrofitting existing buildings are often more difficult to be implemented, and enforcement is still a major issue in Indonesia. Local governments are currently working on streamlining building permit process as well as developing an online monitoring system for existing buildings. By applying a Building Energy Management System (BEMS) enables to reduce energy consumption up to 15%. An energy monitoring system was designed and installed through this research for Department of Nuclear Engineering and Engineering Physics (DNEEP) building, Faculty of Engineering, Universitas Gadjah Mada. It is a 20 years old two-story building used for educational activities, which consist of classrooms, laboratories, offices and storage spaces. An audit energy was done recently in 2015 where an energy consumption of 261.299,636 kWh/year.m2 was reported. In the existing condition, a power meter is inaccessible and therefore, the only feedback of occupancy behavior in the energy consumption is through the electricity bill. The previous study has shown that building occupants would behave more efficiently if the amount of energy used is notified, and the amount of energy savings are recorded. However, these energy monitoring systems are considered expensive and uniquely tailored for every building. This research aims to design and install a cost effective BEMS based on occupant’s satisfactory assessment of the lighting, acoustics, and air conditioning quality. The data will be used as a decision supporting system (DSS) by building management through the use of a GUI. The design of the interface was based on a survey result from the prospective users. Installed energy monitoring system uses a current sensor with an accuracy of 98% and a precision of 0.04 A while the voltage sensor with an accuracy of 98% and a precision of 0.58 V. The performance testing shows that the number of web clients influences delay of data transmission. The result of the survey shows that GUI is categorized as fair in design without a significant difference between the perceptions of users with and without survey supervision.


Sign in / Sign up

Export Citation Format

Share Document