Research on short-circuit current levels in Sverdlovsk power system

Author(s):  
Aleksandr Egorov ◽  
Stanislav Eroshenko ◽  
Aleksandra Khalyasmaa ◽  
Kirill Zinovyev
2021 ◽  
Vol 39 (5A) ◽  
pp. 723-737
Author(s):  
Yamur M. Obied ◽  
Thamir M. Abdul Wahhab

The coordination between protective devices is the process of determining the most appropriate timing of power interruption during abnormal conditions in the power system. The aim of this work is to coordinate the protection of the 33/11 kV power distribution substation in Iraq using the CYME 7.1 software package. In this paper overcurrent and earth fault relays are simulated in two cases, with time delay setting and instantaneous setting, to obtain the Time Current Characteristics (TCC) curves for each Circuit Breaker (CB) relay of Al-Karama substation (2×31.5 MVA, 33/11 kV) in Babil distribution network. The short circuit current at each CB is calculated and accordingly, the protection coordination for Al-Karama substation has been simulated. The TCC curves have been obtained in two cases for overcurrent and earth fault relays; in a case with time delay setting and in the case with the instantaneous setting. The setting takes into consideration the short circuit current at the furthest point of the longest outgoing feeder and the shortest outgoing feeder.


2015 ◽  
Vol 793 ◽  
pp. 65-69 ◽  
Author(s):  
Abadal Salam T. Hussain ◽  
Waleed A. Oraibi ◽  
Fadhel A. Jumaa ◽  
F. Malek ◽  
Syed F. Ahmed ◽  
...  

Electrical Power System protection is required to protectboth the user and the system equipment itself fromany fault, hence electrical power system is not allowed to operate without any protection devices installed. Power System fault is defined as the undesirable condition that occurs in the power system. Some of these undesirable conditions are short circuit, current leakage, ground faultand over-under voltage. With the increasing loads, voltages and short-circuit duty in power plant, over voltage protection has become more important today. Here, the component that had been used is PIC 16F877a microcontroller to control the whole system and especially on the circuit breakers as well as the LCT display unit is used to display the voltage level and type of generator that used to serve the load. Sensors are used to measure both thevoltage and the load. The controlled digital signal from PIC microcontroller is converted by using the digital analog converter to control the whole circuit. Thus a device called protective relay is created to meet this requirement. The protective relay is mostlyoften coupled with circuit breaker in a way that it can isolate the abnormal condition in the system.


2011 ◽  
Vol 219-220 ◽  
pp. 648-651
Author(s):  
Hong Zhang ◽  
Xu Hui Ma ◽  
Xiu Ye Yin

With the development of technology, the power system of offshore facilities (for short: power system) is increasingly complex, short-circuit current calculation process also becomes more complex. The simple recursive algorithm can not meet the requirements of short-circuit current calculation in complex power system. The paper, basing on the principle of short-circuit current calculation, taking modeling ideas, created an equivalent circuit model of power system for short-circuit current calculation. The equivalent circuit model can be used to simplify the progress of calculation and meet the needs of the power system development.