Calculation of the Core Loss of High-Frequency High-Voltage Transformer Considering the Influence of Temperature

Author(s):  
Jinqiao Chen ◽  
Heng Hu ◽  
Shan Jiang ◽  
Le Deng ◽  
Tao Peng
2013 ◽  
Vol 284-287 ◽  
pp. 1136-1140
Author(s):  
Yong Nong Chang ◽  
Chih Ming Kuo

In this paper, a series resonant converter with high-frequency high-voltage transformer for plasma generator is presented. The high-frequency, high-voltage electric source is designed by employing a series load-resonant converter with the plasma generator as part of the electric circuit. The equivalent circuit of this high-frequency transformer modeled by the introduction of the stray capacitance is proposed and the circuit model of the high-voltage plasma generator is conducted as well. Thus, the overall model of the high-voltage plasma generator is built and the designing procedures for appropriate selections of the corresponding resonant-circuit parameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, plus a 22 kHz and over 8kV power converter output, is realized and implemented.