Signal processing for cochlear implants and low-rate speech coding

Author(s):  
P.C. Loizou
2014 ◽  
Vol 926-930 ◽  
pp. 1857-1860
Author(s):  
Zhou Zheng ◽  
Meng Yuan Li ◽  
Wei Jiang Wang

In order to reduce the burden of the calculation and the low frequency resolution of the tradition GNSS signal intermediate narrow band anti-jamming method, it introduces a high efficient approach of narrow band interference rejection based on baseband GNSS signal processing. After digital down conversion to baseband and down sampling to a low rate, the interference is removed in frequency domain. According to the theoretical analysis and simulation, it claims that the method can reduce the calculation and increase the detection resolution in frequency domain which will realize a high efficient interference rejection.


2021 ◽  
Author(s):  
Junhong Chen

In wireless communication, speech is an essential service for which low rate speech coding is a key technique. Reducing the transmission bandwith and achieving higher speech quality are primary concerns in developing new speech coding algorithms. This report develops a joint channel and source controlled adaptive variable bit-rate algorithm to achieve a high speech quality and maintain an efficient spectrum.


2021 ◽  
Author(s):  
Ekaterina A. Lopukhova ◽  
Grigory S. Voronkov ◽  
Igor V. Kuznetsov

2004 ◽  
Vol 5 (S1) ◽  
pp. 45-47
Author(s):  
Chuan-Jen Hsu ◽  
Shih-Hsuan Shiao ◽  
Yuh-Shyang Chen ◽  
Mei-Ji Horng ◽  
Qian-Jie Fu

Author(s):  
S. Roucos ◽  
R. Schwartz ◽  
J. Makhoul
Keyword(s):  

2007 ◽  
Vol 18 (08) ◽  
pp. 700-717 ◽  
Author(s):  
Marios S. Fourakis ◽  
John W. Hawks ◽  
Laura K. Holden ◽  
Margaret W. Skinner ◽  
Timothy A. Holden

The choice of frequency boundaries for the analysis channels of cochlear implants has been shown to impact the speech perception performance of adult recipients (Skinner et al, 1995; Fourakis et al, 2004). While technological limitations heretofore have limited the clinical feasibility of investigating novel frequency assignments, the SPEAR3 research processor affords the opportunity to investigate an unlimited number of possibilities. Here, four different assignments are evaluated using a variety of speech stimuli. All participants accommodated to assignment changes, and no one assignment was significantly preferred. The results suggest that better performance can be achieved using a strategy whereby (1) there are at least 7-8 electrodes allocated below 1000 Hz, (2) the majority of remaining electrodes are allocated between 1100 - 3000 Hz, and (3) the region above 3 kHz is represented by relatively few electrodes (i.e., 1-3). The results suggest that such frequency assignment flexibility should be made clinically available. La escogencia de límites de frecuencia para los canales de análisis de los implantes cocleares se ha visto que impacta el desempeño en la percepción del lenguaje de adultos implantados (Skinner y col, 1995; Fourakis y col, 2004). Mientras que las limitaciones tecnológicas hasta este momento han restringido la factibilidad clínica de investigar nuevas asignaciones de frecuencia, el procesador experimental SPEAR3 ofrece la oportunidad de investigar un número ilimitado de posibilidades. Aquí, se evalúan cuatro asignaciones diferentes utilizando una variedad de estímulos de lenguaje. Todos los participantes se acomodaron a los cambios de asignación y ninguna asignación tuvo una preferencia significativa. Los resultados sugieren que puede obtenerse un desempeño mejor utilizando una estrategia donde (1) existan al menos 7-8 electrodos colocados por debajo de 1000 Hz, (2) la mayoría de los electrodos remanentes sean colocados entre 1100 – 3000 Hz, y (3) la región por encima de 3 kHz esté representada por relativamente pocos electrodos (p.e., 1-3). Los resultados sugieren que tal flexibilidad en la asignación de frecuencias debería estar clínicamente disponible.


Sign in / Sign up

Export Citation Format

Share Document