Effect and influence of residual current compensation on earth-fault distance relays

Author(s):  
Y. Kurosawa ◽  
H. Amoh ◽  
H. Takani
Sensors ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 2044
Author(s):  
Stanislaw Czapp

In many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in low-voltage power systems is commonly performed with the use of residual current devices (RCDs). In the presence of harmonics, the RCDs may have a tripping current significantly different from that provided for the nominal sinusoidal waveform. Thus, in some cases, protection against electric shock may not be effective. The aim of this paper is to present the result of a wide-range laboratory test of the sensitivity of A-type RCDs in the presence of harmonics. This test has shown that the behavior of RCDs in the presence of harmonics can be varied, including the cases in which the RCD does not react to the distorted earth fault current, as well as cases in which the sensitivity of the RCD is increased. The properties of the main elements of RCDs, including the current sensor, for high-frequency current components are discussed as well.


2005 ◽  
Vol 20 (2) ◽  
pp. 573-578 ◽  
Author(s):  
S.F. Huang ◽  
Z.H. Chen ◽  
Y.P. Zhang ◽  
T.S. Bi

2017 ◽  
Vol 66 (3) ◽  
pp. 485-494 ◽  
Author(s):  
Stanislaw Czapp ◽  
Krzysztof Dobrzynski ◽  
Jacek Klucznik ◽  
Zbigniew Lubosny ◽  
Robert Kowalak

Abstract For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed the modification in the structure of residual current devices. This modification improves sensitivity of residual current devices when high frequency earth fault current occurs. The test of the modified residual current device proved that the authors’ proposition is appropriate.


Sign in / Sign up

Export Citation Format

Share Document