scholarly journals A Significance Test for Reverberation-Chamber Measurement Uncertainty in Total Radiated Power of Wireless Devices

2016 ◽  
Vol 58 (1) ◽  
pp. 207-219 ◽  
Author(s):  
Kate A. Remley ◽  
Chih-Ming Jack Wang ◽  
Dylan F. Williams ◽  
Johannes J. aan den Toorn ◽  
Christopher L. Holloway
2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Dong-Uk Sim ◽  
Sang Il Kwak ◽  
Jong Hwa Kwon ◽  
Seong-Ook Park

This paper proposes a reverberation chamber structure consisting of new reflectors and mode stirrers for electromagnetic compatibility and wireless terminal measurements. The key design considerations for them are determined through a reasonable approach to analyze the eigenmode for a reverberation chamber and the standard deviation of its working volume based on 3D simulation. The final designs are expected to improve the standard deviation performance of the initial structure of the reverberation chamber and provide a better mode stirring environment. The results measured in the fabricated chamber demonstrate that these predictions are clearly realized. The results satisfy the main requirements of this paper, which are defined in consideration of the specifications of commercial reverberation chamber products. Therefore, the reverberation chamber of this paper is expected to be useful for performance measurement and evaluation of commercial wireless terminals. To verify this logical approach to obtain a good design and its results, the results measured in the actual fabricated reverberation chamber are described along with analytical and computational results.


2021 ◽  
Vol 36 (9) ◽  
pp. 1152-1158
Author(s):  
Wei Xue ◽  
Yuxin Ren ◽  
Xiaoming Chen ◽  
Zhengpeng Wang ◽  
Yingsong Li ◽  
...  

2019 ◽  
Vol 69 (5) ◽  
pp. 427-430
Author(s):  
Deepshikha Gururani ◽  
Harish S. Rawat ◽  
Satya K. Dubey ◽  
V.N. Ojha

With the increased use of wireless communication in recent years, the use of reverberation chamber (RC) has increased to a great extent. Reverberation chambers have been eminently used for EMC testing and shielding effectiveness. The environment it provides is very similar to the reverberant surroundings that antenna undergoes in real life use. An experiment to measure total radiated power of antenna, antenna efficiency and quality factor of chamber in indoor environment is proposed. This will make the measurement very simple and inexpensive as designing and calibration of chamber will not be needed. In this paper, we have used three different techniques to compare total radiated power, quality factor, Rician K factor and efficiency of a patch antenna measured in indoor environment with RC data. The three method used include plate stirring method and two time domain methods. The time domain methods use modulated pulse and Gaussian pulse respectively for the measurement. The antenna and chamber parameters are measured in the real time and the data matched well with the RC data for different techniques.


Sign in / Sign up

Export Citation Format

Share Document