FPGA-Based Short Horizon Integration Voltage Reconstruction Method for Three Level Neutral Point Clamped Inverter

Author(s):  
Naizhe Diao ◽  
Xianrui Sun ◽  
Chonghui Song ◽  
Haifeng Zhang
Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2616 ◽  
Author(s):  
Yungdeug Son ◽  
Jangmok Kim

This paper presents three phase current reconstruction methods for a three-level neutral point clamped inverter (NPCI) by measuring the voltage of a shunt resistor placed in the neutral point of the inverter. In order to accurately acquire the phase currents from the shunt resister, the dwell time of the active voltage vectors need to exceed the minimum time. On the other hand, if the time of active voltage is shorter than the minimum time, the current measurement becomes impossible. In this paper, unmeasurable regions for current are classified into three areas. Area 1 is a region in which both phase currents can be measure. Therefore, it is not necessary to restore the current. In Area 2, only one phase current can be measured. Thus, an estimation or restoration method is needed to measure another phase current. In this paper, the current estimation method using an electrical model of the motor is proposed. Area 3 is the region in which both phase currents can not be measured. In this case, it is necessary to move the voltage vector to the current measurable area by injecting the voltage. In this paper, Area 3 is divided into 36 sectors to inject optimal voltage. The proposed methods have the advantages of high current measurement accuracy and low THD (total harmonic distortion). The effectiveness of the proposed methods are verified through experimental results.


Author(s):  
Neng-Yu Zhang ◽  
Terence Wagenknecht ◽  
Michael Radermacher ◽  
Tom Obrig ◽  
Joachim Frank

We have reconstructed the 40S ribosomal subunit at a resolution of 4 nm using the single-exposure pseudo-conical reconstruction method of Radermacher et al.Small (40S) ribosomal subunits were Isolated from rabbit reticulocytes, applied to grids and negatively stained (0.5% uranyl acetate) in a manner that “sandwiches” the specimen between two layers of carbon. Regions of the grid exhibiting uniform and thick staining were identified and photographed twice (magnification 49,000X). The first micrograph was always taken with the specimen tilted by 50° and the second was of the Identical area untilted (Fig. 1). For each of the micrographs the specimen was subjected to an electron dose of 2000-3000 el/nm2.Three hundred thirty particles appearing in the L view (defined in [4]) were selected from both tilted- and untilted-specimen micrographs. The untilted particles were aligned and their rotational alignment produced the azimuthal angles of the tilted particles in the conical tilt series.


2009 ◽  
Vol 129 (1) ◽  
pp. 15-21 ◽  
Author(s):  
Shoichi Urano ◽  
Takeshi Yamada ◽  
Yoshifumi Ooura ◽  
Youheng Xu ◽  
Yasutaka Yamaguchi ◽  
...  

2020 ◽  
Vol 25 (3) ◽  
pp. 265-276
Author(s):  
K.M. Shepilova ◽  
◽  
A.V. Sotnikov ◽  
A.V. Shipatov ◽  
Yu.V. Savchenko ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document