Recursive SISO Impedance Modeling of Single-Phase Voltage Source Rectifiers

Author(s):  
Jianheng Lin ◽  
Mei Su ◽  
Yao Sun ◽  
Dongsheng Yang ◽  
Shiming Xie
2021 ◽  
Author(s):  
Jianheng Lin

<p>This paper proposes a recursive single-input single-output (SISO) impedance modeling framework for single-phase voltage source rectifiers, which can greatly simplify both the modeling procedure and the resulting impedance model. During the modeling process, frequency-coupling effects are modeled by the reduced-order transfer function vector rather than the transfer function matrix, so the modeling complexity is reduced. Moreover, the recursive SISO impedance model has an analytical form. And the recursive SISO impedance model can characterize the frequency-coupling dynamics of arbitrary order with a low computation burden. Experiments validate the accuracy of the recursive SISO impedance modeling.<br></p>


2020 ◽  
Author(s):  
Jianheng Lin ◽  
Mei Su ◽  
Yao Sun ◽  
Shiming Xie

Time-periodicity and non-linearity pose a challenge to the precise input impedance modeling of single-phase power converters. In this study, a precise input impedance model with measurability of the single-phase voltage source rectifier (VSR), which considers the frequency-coupling effect (FCE), is established. Meanwhile, it is revealed that the rectifier input impedance is dependent of the grid impedance. In the proposed modeling approach, only Laplace transform and frequencyshifting operation are required, which avoids the complicated convolution calculation in the frequency domain. In addition, the influence of grid impedance on the input impedance is studied. Simulations are conducted to verify the effectiveness of the proposed method. <br>


2021 ◽  
Author(s):  
Jianheng Lin

<p>This paper proposes a recursive single-input single-output (SISO) impedance modeling framework for single-phase voltage source rectifiers, which can greatly simplify both the modeling procedure and the resulting impedance model. During the modeling process, frequency-coupling effects are modeled by the reduced-order transfer function vector rather than the transfer function matrix, so the modeling complexity is reduced. Moreover, the recursive SISO impedance model has an analytical form. And the recursive SISO impedance model can characterize the frequency-coupling dynamics of arbitrary order with a low computation burden. Experiments validate the accuracy of the recursive SISO impedance modeling.<br></p>


2020 ◽  
Author(s):  
Jianheng Lin ◽  
Mei Su ◽  
Yao Sun ◽  
Shiming Xie

Time-periodicity and non-linearity pose a challenge to the precise input impedance modeling of single-phase power converters. In this study, a precise input impedance model with measurability of the single-phase voltage source rectifier (VSR), which considers the frequency-coupling effect (FCE), is established. Meanwhile, it is revealed that the rectifier input impedance is dependent of the grid impedance. In the proposed modeling approach, only Laplace transform and frequencyshifting operation are required, which avoids the complicated convolution calculation in the frequency domain. In addition, the influence of grid impedance on the input impedance is studied. Simulations are conducted to verify the effectiveness of the proposed method. <br>


2021 ◽  
Vol 2 (2) ◽  
pp. 44-53
Author(s):  
GENNADY S. MYTSYK ◽  
◽  
ZAW HTET HEIN ◽  

The recent interest of developers of new technology in studying a structural and algorithmic synthesis (SAS) of voltage source inverters (VSI) for solar power plants (SPP) is stemming from a growing need to solve problems in connection with the revealed new possibilities of converting energy flow (from DC to AC) with better energy efficiency by reducing the depth of its pulse modulation. This problem is solved by using more rational structural and algorithmic solutions. It is shown that for SPPs for a capacity of about 1 MW and more, it is more expedient to construct inverters based on the energy flow multichannel conversion principle. Given a limited power capacity of the transistor components, the application of this principle allows the problem to be solved in fact without using an output filter. The output voltage waveform is shaped using the energy flow pulse-amplitude modulation (PAM), and its M parts are summed in the output circuit by out using M winding transfilters (M-TF). The proposed method for carrying out combined SAS of single-phase voltage source inverters with multichannel conversion is considered, which consists in using an N-level single-phase VSI (N-SPVSI) in each of the M channels with the voltage levels optimized in terms of the minimum total harmonic distortion (THD). The resulting voltage of this class of single-phase inverters, designated as MxN-SPVSI, is formed by the corresponding phase shift of the channel voltages followed by summing the channel currents by M-TF. It is shown that the resulting output voltage levels are also close to their values optimized with respect to the minimum of the THD indicator. The results from a comparative analysis of two options — a single-channel 8-level inverter and a four-channel 8-level inverter are given. For the second option, only one intermediate voltage tap in the solar battery is required (instead of seven taps in the first option) along with modern transistor components that are available for practical implementation. In both options, the THD value less than 5% is obtained with almost no need of using an output filter. The presented results provide a certain information and methodological support for system designing of single-phase voltage source inverters as applied to the specific features of solar power plants. Three-phase inverters can be built on the basis of three single-phase inverters with galvanic isolation of the power sources for each phase.


Sign in / Sign up

Export Citation Format

Share Document