scholarly journals Determination of the Minimum Break Point Set Using Expert System and Genetic Algorithm

2010 ◽  
Vol 25 (3) ◽  
pp. 1284-1295 ◽  
Author(s):  
Hoda Sharifian ◽  
H. Askarian Abyaneh ◽  
Salman. K. Salman ◽  
Reza Mohammadi ◽  
Farzad Razavi
2019 ◽  
Author(s):  
Carmen Guguta ◽  
Jan M.M. Smits ◽  
Rene de Gelder

A method for the determination of crystal structures from powder diffraction data is presented that circumvents the difficulties associated with separate indexing. For the simultaneous optimization of the parameters that describe a crystal structure a genetic algorithm is used together with a pattern matching technique based on auto and cross correlation functions.<br>


1998 ◽  
Vol 81 (5) ◽  
pp. 1077-1086
Author(s):  
Biljana F Abramovic ◽  
Borislav K Abramovic ◽  
Ferenc F Gaál ◽  
Danilo M Obradovtc

Abstract An expert system (ES) to solve the problem of choosing a catalytic titrimetric procedure for determining monobasic carboxylic acids is described. Carboxylic acids were divided into 3 groups—aliphatic, aromatic, and α-aminocarboxylic acids— based on their behavior in catalytic titrations with different indicator reactions, titrant, and/or solvent and the possibility of their selective determination in the presence of other acids


2021 ◽  
Vol 19 (1) ◽  
pp. 205-213
Author(s):  
Hany W. Darwish ◽  
Abdulrahman A. Al Majed ◽  
Ibrahim A. Al-Suwaidan ◽  
Ibrahim A. Darwish ◽  
Ahmed H. Bakheit ◽  
...  

Abstract Five various chemometric methods were established for the simultaneous determination of azilsartan medoxomil (AZM) and chlorthalidone in the presence of azilsartan which is the core impurity of AZM. The full spectrum-based chemometric techniques, namely partial least squares (PLS), principal component regression, and artificial neural networks (ANN), were among the applied methods. Besides, the ANN and PLS were the other two methods that were extended by genetic algorithm procedure (GA-PLS and GA-ANN) as a wavelength selection procedure. The models were developed by applying a multilevel multifactor experimental design. The predictive power of the suggested models was evaluated through a validation set containing nine mixtures with different ratios of the three analytes. For the analysis of Edarbyclor® tablets, all the proposed procedures were applied and the best results were achieved in the case of ANN, GA-ANN, and GA-PLS methods. The findings of the three methods were revealed as the quantitative tool for the analysis of the three components without any intrusion from the co-formulated excipient and without prior separation procedures. Moreover, the GA impact on strengthening the predictive power of ANN- and PLS-based models was also highlighted.


Sign in / Sign up

Export Citation Format

Share Document