A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids

2017 ◽  
Vol 32 (6) ◽  
pp. 4943-4953 ◽  
Author(s):  
Chengyu Li ◽  
Chengyong Zhao ◽  
Jianzhong Xu ◽  
Yuke Ji ◽  
Fan Zhang ◽  
...  
2019 ◽  
Vol 34 (1) ◽  
pp. 826-826
Author(s):  
Chengyu Li ◽  
Chengyong Zhao ◽  
Jianzhong Xu ◽  
Yuke Ji ◽  
Fan Zhang ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1347
Author(s):  
Haipeng Jia ◽  
Jingyuan Yin ◽  
Tongzhen Wei ◽  
Qunhai Huo ◽  
Jinke Li ◽  
...  

The analysis and calculation of the short-circuit fault current in the DC grid is of great significance to the design and configuration of the converter station and DC circuit breaker parameters. The existing flexible DC system not only includes the modular multilevel converter (MMC) converter, but also needs power equipment such as the fault current limiter and DC circuit breaker. Therefore, the system modeling and short circuit calculation of the multi-terminal DC system after adding the DC circuit breaker are also of great significance for the design of DC power system parameters and the grid troubleshooting ability. In this paper, firstly, the parameters of the four-terminal DC system of the modular multilevel converter (MMC) are simplified, and the analytical solution of the short circuit fault current of the multi-terminal DC system is given. Then, the external characteristics of the cascaded hybrid DC circuit breaker are modeled. Based on the equivalent circuit of the fault current in different stages, the short circuit calculation method of four-terminal MMC system with DC circuit breaker is obtained. This method can effectively describe the overall trend of fault current and provide the basis for the configuration of DC line protection settings and DC circuit breaker related parameters.


2019 ◽  
Vol 9 (9) ◽  
pp. 1737 ◽  
Author(s):  
Bin Jiang ◽  
Yanfeng Gong

A modular multilevel converter based high-voltage DC (MMC-HVDC) system has been the most promising topology for HVDC. A reclosing scheme is usually configured because temporary faults often occur on transmission lines especially when overhead lines are used, which often brings about an overcurrent problem. In this paper, a new fault current limiter (FCL) based on reclosing current limiting resistance (RCLR) is proposed to solve the overcurrent problem during the reclosing process. Firstly, a mesh current method (MCM) based short-circuit current calculation method is newly proposed to solve the fault current calculation of a loop MMC-HVDC grid. Then the method to calculate the RCLR is proposed based on the arm current to limit the arm currents to a specified value during the reclosing process. Finally, a three-terminal loop MMC-HVDC test grid is constructed in the widely used electromagnetic transient simulation software PSCAD/EMTDC and the simulations prove the effectiveness of the proposed strategy.


Sign in / Sign up

Export Citation Format

Share Document