scholarly journals A Current Limiting Strategy to Improve Fault Ride-Through of Inverter Interfaced Autonomous Microgrids

2017 ◽  
Vol 8 (5) ◽  
pp. 2138-2148 ◽  
Author(s):  
Iman Sadeghkhani ◽  
Mohamad Esmail Hamedani Golshan ◽  
Josep M. Guerrero ◽  
Ali Mehrizi-Sani
2014 ◽  
Vol 556-562 ◽  
pp. 1959-1963
Author(s):  
Si Ming Wei ◽  
Yi Gong Zhang ◽  
Huan Liu ◽  
Zhi Qiang Dai ◽  
Xiao Du

It is great significance for development of MTDC (Multi-terminal HVDC) to build DC transmission and distribution grids. However, the relatively low impedance in DC grids makes the fault penetration much faster and deeper .Consequently, fast and reliable DC circuit breaker is needed to isolate faults. Breaking time and other parameters are important for a breaker to achieve its goals. This paper presents a DC circuit breaker with a current-limiting inductance and gets the rising and falling characteristics of fault current. Based on the characteristics, a design method of breaking time sequence will be given, as well as the calculation of current-limiting inductance and the selection principles of arresters. A 10kV DC distribution grid is modeled and simulated by PSCAD/EMTDC to verify that the method can meet the requirements of breaking fault current quickly and reliably.


2018 ◽  
Vol 8 (11) ◽  
pp. 2059 ◽  
Author(s):  
Seyed Naderi ◽  
Pooya Davari ◽  
Dao Zhou ◽  
Michael Negnevitsky ◽  
Frede Blaabjerg

The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems. Due to partial rated back-to-back converters in the doubly-fed induction generator, fault ride-through capability improvement is one of the important subjects in relation to new grid code requirements. To enhance the fault ride-through capability of the doubly-fed induction generator, many studies have been carried out. Fault current limiting devices are one of the techniques utilised to limit the current level and protect the switches, of the back-to-back converter, from over-current damage. In this paper, a review is carried out based on the fault current limiting characteristic of fault current limiting devices, utilised in the doubly-fed induction generator. Accordingly, fault current limiters and series dynamic braking resistors are mainly considered. Operation of all configurations, including their advantages and disadvantages, is explained. Impedance type and the location of the fault current limiting devices are two important factors, which significantly affect the behaviour of the doubly-fed induction generator in the fault condition. These two factors are studied by way of simulation, basically, and their effects on the key parameters of the doubly-fed induction generator are investigated. Finally, future works, in respect to the application of the fault current limiter for the improvement of the fault ride-through of the doubly-fed induction generator, have also been discussed in the conclusion section.


1982 ◽  
Vol PER-2 (9) ◽  
pp. 34-35 ◽  
Author(s):  
B. P. Raju ◽  
K. C. Parton ◽  
T. C. Bartram
Keyword(s):  

2013 ◽  
Vol 722 ◽  
pp. 223-227
Author(s):  
Tie Ying Zhao ◽  
Yan Wen Wang

Current limiting reactor can increase systems short circuit impedance so as to limit short circuit current. Current limiting reactor is directly involved in whole short circuit process when a short circuit fault occurs in a power system, which makes short-circuit current change more complex. Short circuit current level is affected by current limiting reactors parameters; a current limiting reactor with proper impedance value can maintain short-circuit current at an acceptable range. A short circuit transient process of a distributing network with current limiting reactor was analyzed, and the formula of current changing in short circuit transient process was deduced; according to the current changing formula, an engineering calculation formula of current limiting reactors impedance was derived. The case calculation shows that current limiting reactor meeting the need of the engineering calculation formula can reach the system current limiting requirement.


2021 ◽  
Author(s):  
Yang Shen ◽  
Huihua Liu ◽  
Shuangfeng Kong ◽  
Yiming Yu ◽  
Yunqiu Wu ◽  
...  
Keyword(s):  

2013 ◽  
Vol 23 (3) ◽  
pp. 5500104-5500104 ◽  
Author(s):  
M. Iwakuma ◽  
Y. Katanosaka ◽  
S. Sato ◽  
H. Hayashi ◽  
H. Okamoto ◽  
...  
Keyword(s):  