fault ride through
Recently Published Documents


TOTAL DOCUMENTS

864
(FIVE YEARS 310)

H-INDEX

45
(FIVE YEARS 8)

2022 ◽  
Vol 158 ◽  
pp. 112125
Author(s):  
Kamran Zeb ◽  
Saif Ul Islam ◽  
Imran Khan ◽  
Waqar Uddin ◽  
M. Ishfaq ◽  
...  

Author(s):  
Ashok Babu Valluri

Abstract: For ever increasing power demand and depletion of conventional energy resources, Renewable Energy Systems (RES) became an alternative source of electricity to reduce the load stress on the Power Grid. Although several control & design modifications are presented in past literature to improve reliability & performance of through Distribution Generation (DG) technologies, they always fall short in some aspects of voltage stability and Fault Ride Through (FRT) capabilities. The main aim of the project is Protecting Critical load from Grid side altercations which occur due to harmonics generated by DG’s and Short circuit faults near to load center. This project proposes the application of a Dynamic Voltage Restorer (DVR) to enhance the power quality and improve the Fault Ride Through (FRT) capability of a three-phase medium-voltage network connected to a hybrid distribution generation (DG) system. In this hybrid farm, the Photo Voltaic (PV) plant via single-stage energy conversion (DC-AC inverter) & DFIG (Doubly-Fed Induction Generator) based Wind power plant are connected to the same Point of Common Coupling (PCC). For MPPT of wind power plant, we use Pitch Angle Control (PAC) technique. This topology allows Perturb and observe (P&O) based MPPT algorithm for PV plant through connection of the DG (Distribution generation) system to the public grid through a step-up transformer. In addition, the DVR based on Artificial Neural Network (ANN) controller is connected to the same PCC. Different fault condition scenarios are tested for improving the efficiency and the quality of the power supply and compliance with the requirements of the sensitive Load. The efficiency of this control technique is that it enhances restoration and harmonics suppression capabilities of DVR which are far superior than that of PI controller used in existing model. Keywords: RES, DG, LVRT, FRT, PV, DFIG, PCC, MPPT, P&O, DVR, PI, ANN, THD, Voltage stability.


2021 ◽  
Author(s):  
Janaka Ekanayake

The concept of microgrids goes back to the early years of the electricity industry although the systems then were not formally called microgrids. Today, two types of microgrids can be seen: independent and grid connected. The protection requirement of these two types differs as the protection needs of an independent microgrid are intended for protecting components and systems within the microgrid, whereas a grid connected microgrid demands both internal and external protection. The first part of this chapter is dedicated to independent microgrids. How protection devices such as residual current circuit breakers, miniature and moulded case circuit breakers, and surge protective devices should be selected for an example microgrid is discussed while referring to the relevant standards. In the next section, the protection of a grid connected microgrid is discussed. Particularly, micro-source protection, microgrid protection, loss of mains protection and fault ride-through requirements are discussed while referring to two commonly used distributed generator connection codes. An example with simulations carried out in the IPSA simulation platform was used to explain different protection requirements and calculation procedures. Finally, grounding requirements are discussed while referring to different interfacing transformer connections and voltage source inverter connections.


2021 ◽  
Author(s):  
M A Awal ◽  
Md Rifat Kaisar Rachi ◽  
Hui Yu ◽  
Iqbal Husain ◽  
Srdjan Lukic

A double synchronous unified virtual oscillator controller (dsUVOC) is proposed for grid-forming voltage source converters to achieve synchronization to the fundamental frequency positive- and negative-sequence components of unbalanced or distorted grids. The proposed controller leverages a positive- and a negative-sequence virtual oscillator, a double-sequence current reference generator, and a double-sequence vector limiter. Under fault conditions, the controller enables to clamp the converter output current below the maximum value limited by the converter hardware while retaining synchronization without a phase-locked-loop (PLL) regardless of the balanced or unbalanced nature of grid faults. Consequently, balanced and unbalanced fault ride-through can be achieved without the need for switching to a back-up controller. The paper presents the systematic development of the double-synchronous structure along with detail design and implementation guidelines. Validation of the proposed controller is provided through extensive control-hardware-in-the-loop (CHIL) and laboratory hardware experiments.


2021 ◽  
Vol 201 ◽  
pp. 107524
Author(s):  
Fayçal Benyamina ◽  
Abdeldjabar Benrabah ◽  
Farid Khoucha ◽  
Muhammad Fahad Zia ◽  
Yahia Achour ◽  
...  

Author(s):  
Muhammad Talha ◽  
Siti Rohani S. Raihan ◽  
Nasrudin Abd. Rahim

2021 ◽  
Author(s):  
Hani Muhsen ◽  
Asma Alkhraibat ◽  
Hisham ElMoaqet
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document