MonTerDC: Data Center Thermal Monitoring System

Author(s):  
Ademir Camillo ◽  
Mauricio A. Pillon ◽  
Charles C. Miers ◽  
Guilherme P. Koslovski
2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Joyoung Lee ◽  
Zijia Zhong ◽  
Bo Du ◽  
Slobodan Gutesa ◽  
Kitae Kim

This paper presents a low-cost and energy-saving urban mobility monitoring system based on wireless sensor networks (WSNs). The primary components of the proposed sensor unit are a Bluetooth sensor and a Zigbee transceiver. Within the WSN, the Bluetooth sensor captures the MAC addresses of Bluetooth units equipped in mobile devices and car navigation systems. The Zigbee transceiver transmits the collected MAC addresses to a data center without any major communications infrastructures (e.g., fiber optics and 3G/4G network). A total of seven prototype sensor units have been deployed on roadway segments in Newark, New Jersey, for a proof of concept (POC) test. The results of the POC test show that the performance of the proposed sensor unit appears promising, resulting in 2% of data drop rates and an improved Bluetooth capturing rate.


1994 ◽  
Vol 37 (3) ◽  
Author(s):  
F. Ringdal

The UN Conference on Disarmament's Group of Scientific Experts (GSE) was established in 1976 to consider international co operative measures to detect and identify seismic events. Over the years, the GSE has developed and tested several concepts for an International Seismic Monitoring System (ISMS) for the purpose of assisting in the verification of a potential comprehensive test ban treaty. The GSE is now planning its third global technical test. (GSETT 3) in order to test new and revisled concepts for an ISMS. GSETT 3 wili be an unprecedented global effort to conduct an operationally realistic test of rapid collection, distribution and processing of seismie data. A global network of seismograph stations will provide data to an International Data Center, where the data will be processed an results made available to participants. The full scaIe phase of GSETT 3 is scheduled to begin in January 1995.


Sensor Review ◽  
2021 ◽  
Vol 41 (4) ◽  
pp. 350-360
Author(s):  
Xiao Fang ◽  
Yajie Zeng ◽  
Feng Xiong ◽  
Jiang Chen ◽  
Fei Cheng

Purpose Seepage of the dam is an important safety problem, which may cause internal erosion of the structure. In the field of seepage monitoring in civil engineering, the distributed optical fiber sensing technology based on the temperature tracing method has been paid more attention due to its unique advantages of high sensitivity, good stability and high resolution. The purpose of this paper is to make a review of the existing related research, so as to facilitate the later scholars to understand and further study more systematically. Design/methodology/approach In this paper, three kinds of commonly used distributed fiber temperature measurement technologies are introduced. Based on the working principle, monitoring system, theoretical analysis, experimental research and engineering application of the fiber seepage monitoring technology, the present situation of dam seepage monitoring based on distributed fiber is reviewed in detail and their advantages and disadvantages are compared. Findings The thermal monitoring technology of seepage measurement depends on the accuracy of optical fiber temperature measurement (including the accuracy of the system and the rationality of the discrimination method), the correct installation of optical fiber and the quantitative analysis of temperature data. The accuracy of the current monitoring system can basically meet the existing measurement requirements, but the correct installation of optical fiber and the calibration of temperature data need to be further studied for different discrimination methods, and this field has great research value. Originality/value At present, there are many applications and research studies of optical fiber sensing in the field of structural health monitoring, and there are also reviews of related aspects. However, there is little or no review only in the field of seepage monitoring. This paper summarizes the research and application of optical fiber sensing in the field of seepage monitoring. The possibility of the gradient method to find its new prospect with the development of monitoring systems and the improvement of temperature resolution is discussed. The idea of extending the seepage monitoring method based on distributed optical fiber thermal monitoring technology to other monitoring fields is also given in the paper.


2014 ◽  
Vol 556-562 ◽  
pp. 2810-2815
Author(s):  
Zhi Xiang Yuan ◽  
Shuang Bo Lai ◽  
Ming Liu ◽  
Hui Yi Zhang

Traditional datacenter temperature monitoring method is to install some temperature sensors which are unable to cover all areas completely, so there are some problems about local hot spot. The method is aiming to find out the position of potential hazard which may exist in the data center on the basis of data center thermal environment evaluation method and characteristics of air distribution. By applying this method into the wireless sensor network monitoring system, it brings a meaningful improvement of the monitoring system.


Sign in / Sign up

Export Citation Format