scholarly journals Quantitative assessment of sodium mass removal using ionic dialysance and sodium gradient as a proxy tool: comparison of high‐flux hemodialysis versus online hemodiafiltration

2021 ◽  
Author(s):  
Annie Rodriguez ◽  
Marion Morena ◽  
Anne‐Sophie Bargnoux ◽  
Leila Chenine ◽  
Hélène Leray‐Moragues ◽  
...  
2021 ◽  
Vol 1 (2) ◽  
pp. 149-151
Author(s):  
Bernard Canaud

Restoring sodium and fluid homeostasis in hemodialysis (HD) patients is a crucial aim to reduce cardiovascular burden and improve global outcome. This crucial target is achieved at maximum in one quarter of HD patients according to a recent study. Sodium and fluid balance relies on a multitarget approach involving dietary salt restriction, dialysis salt mass removal and eventually residual kidney function. Salt mass removal in hemodialysis relies on ultrafiltration (convective sodium), the dialysate–plasma sodium gradient (diffusive sodium) and total treatment time. Manual dialysate sodium prescription has three major aims: dialysate–plasma sodium gradient; sodium mass removal target; hemodialysis tolerance and patient risks. In the future, automated dialysate sodium adjustment by HD machine will facilitate this aim.


2020 ◽  
Author(s):  
José‐Carlos Delgado‐González ◽  
Carlos‐de‐la Rosa Prieto ◽  
Nuria Vallejo‐Calcerrada ◽  
Diana‐Lucía Tarruela‐Hernández ◽  
Sandra Cebada‐Sánchez ◽  
...  

VASA ◽  
2017 ◽  
Vol 46 (5) ◽  
pp. 383-388 ◽  
Author(s):  
Henrik Christian Rieß ◽  
Anna Duprée ◽  
Christian-Alexander Behrendt ◽  
Tilo Kölbel ◽  
Eike Sebastian Debus ◽  
...  

Abstract. Background: Perioperative evaluation in peripheral artery disease (PAD) by common vascular diagnostic tools is limited by open wounds, medial calcinosis or an altered collateral supply of the foot. Indocyanine green fluorescent imaging (ICG-FI) has recently been introduced as an alternative tool, but so far a standardized quantitative assessment of tissue perfusion in vascular surgery has not been performed for this purpose. The aim of this feasibility study was to investigate a new software for quantitative assessment of tissue perfusion in patients with PAD using indocyanine green fluorescent imaging (ICG-FI) before and after peripheral bypass grafting. Patients and methods: Indocyanine green fluorescent imaging was performed in seven patients using the SPY Elite system before and after peripheral bypass grafting for PAD (Rutherford III-VI). Visual and quantitative evaluation of tissue perfusion was assessed in an area of low perfusion (ALP) and high perfusion (AHP), each by three independent investigators. Data assessment was performed offline using a specially customized software package (Institute for Laser Technology, University Ulm, GmbH). Slope of fluorescent intensity (SFI) was measured as time-intensity curves. Values were compared to ankle-brachial index (ABI), slope of oscillation (SOO), and time to peak (TTP) obtained from photoplethysmography (PPG). Results: All measurements before and after surgery were successfully performed, showing that ABI, TTP, and SOO increased significantly compared to preoperative values, all being statistically significant (P < 0.05), except for TTP (p = 0.061). Further, SFI increased significantly in both ALP and AHP (P < 0.05) and correlated considerably with ABI, TTP, and SOO (P < 0.05). Conclusions: In addition to ABI and slope of oscillation (SOO), the ICG-FI technique allows visual assessment in combination with quantitative assessment of tissue perfusion in patients with PAD. Ratios related to different perfusion patterns and SFI seem to be useful tools to reduce factors disturbing ICG-FI measurements.


Sign in / Sign up

Export Citation Format

Share Document