scholarly journals Effects of two fretting damage modes on the dental implant–abutment interface and the generation of metal wear debris: An in vitro study

Author(s):  
Jing Gao ◽  
Jie Min ◽  
Xin Chen ◽  
Ping Yu ◽  
Xin Tan ◽  
...  
Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 385
Author(s):  
Igor Smojver ◽  
Marko Vuletić ◽  
Dražena Gerbl ◽  
Ana Budimir ◽  
Mato Sušić ◽  
...  

The microenvironment of the oral cavity is altered when an implant, a biocompatible foreign body, is inserted into the mouth. Bacteria settle in the tissues in and around the implant due to the passage of microorganisms through the microgap at the connection of the implant and prosthetic abutment. To prevent colonization of the implant by microorganisms, one idea is to use sealing and antimicrobial materials to decontaminate the implant–abutment interface and close the microgap. The purpose of this study is to evaluate the antimicrobial efficacy and permeability of different types of sealing materials at the implant–abutment interface, under static conditions. Three different sealing material (GapSeal gel, Oxysafe gel and Flow.sil) were used for sealing the implant–abutment interfaces in 60 titanium dental implants, which were first contaminated with a solution containing Staphylococcus aureus and Candida albicans for 14 days under an aerobic condition. Results showed that a complete seal against bacterial infection was not formed at the implant–abutment interface, while for fungal infections, only GapSeal material helped to prevent microleakage. Findings of this in vitro study reported that application of sealing material before abutment connection may reduce peri-implant bacterial and fungal population compared with the interface without sealing material.


2015 ◽  
Vol 25 (3) ◽  
pp. 216-223 ◽  
Author(s):  
Helios A. Zeno ◽  
Renan L. Buitrago ◽  
Sidney S. Sternberger ◽  
Marisa E. Patt ◽  
Nick Tovar ◽  
...  

2002 ◽  
Vol 73 (11) ◽  
pp. 1292-1298 ◽  
Author(s):  
Matthias Kreisler ◽  
Wolfgang Kohnen ◽  
Claudio Marinello ◽  
Hermann Götz ◽  
Heinz Duschner ◽  
...  

2018 ◽  
Vol 29 ◽  
pp. 294-294
Author(s):  
Eduardo Claudio Lopes de Chaves E. Mello Dias ◽  
Marcelo Sperandio ◽  
Marcelo Henrique Napimoga

2018 ◽  
Vol 33 (4) ◽  
pp. 747-753 ◽  
Author(s):  
Rubén Agustín-Panadero ◽  
Ana Roig-Vanaclocha ◽  
Antonio Fons-Font ◽  
María Solá-Ruíz

2019 ◽  
Vol 30 (S19) ◽  
pp. 365-365
Author(s):  
Agne Gedrimiene ◽  
Vygandas Rutkunas ◽  
Darius Jegelevicius ◽  
Mykolas Akulauskas ◽  
Dainius Barauskis ◽  
...  

2014 ◽  
Vol 40 (1) ◽  
pp. 30-34 ◽  
Author(s):  
Simonetta D'Ercole ◽  
Antonio Scarano ◽  
Vittoria Perrotti ◽  
Jorge Mulatinho ◽  
Adriano Piattelli ◽  
...  

Prevention of microbial leakage at the implant-abutment junction is a major challenge for the construction of 2-stage implants in order to minimize inflammatory reactions and to maximize bone stability at the implant neck. The aim of the present in vitro study was an evaluation of the leakage observed over a period of 28 days in Cone Morse taper internal connections and in screwed-abutments connections. In the present study 10 specimens of Cone Morse (Group 1) and 10 of internal hexagon (Group 2) implants were used. The inner parts of 5 implants per group were inoculated with Pseudomonas aeruginosa (PS) suspension and 5 implants per group with Aggregatibacter actinomycetemcomitans (AA). The possible penetration of bacterial suspension into the surrounding solution was determined by the observation of turbidity of the broth. In Group 1, bacterial contamination was found in 3 out of 5 implant-abutment assemblies seeded with the PS and in 2 samples out of 5 in the assemblies seeded with AA, with a total of leaked assemblies in this group of 5 out of 10. In Group 2, bacterial contamination was found in 4 out of 5 implant-abutment assemblies seeded with the PS, and in 4 out of 5 samples seeded with AA, with a total of leaked assemblies of 8 out of 10. The present data confirm the reported high permeability to bacterial leakage of screw-retained abutment connections, and the lower infiltration rates—although not significantly—of Cone Morse taper internal connections.


Sign in / Sign up

Export Citation Format

Share Document