Barium Titanates With Improved Insulation Resistance and Time Constant

1963 ◽  
Vol 46 (11) ◽  
pp. 516-518 ◽  
Author(s):  
S. R. HOH ◽  
F. E. PIRIGYI
1968 ◽  
Vol 11 (4) ◽  
pp. 842-852 ◽  
Author(s):  
H. N. Wright

Previous findings on the threshold for tones as a function of their duration have suggested that such functions may be systematically affected by sensori-neural hearing losses of cochlear origin. The present series of investigations was designed to explore this relation further and to determine also whether the amount of hearing loss present has any effect upon the results which are obtained. Preliminary studies were also carried out on a conductively impaired listener to indicate whether hearing losses of this type affect the threshold-duration function. The results indicate that the threshold-duration function is systematically affected by sensori-neural hearing losses of cochlear origin. This effect is manifested by a progressive shortening of the time constant relating threshold to duration and is not uniquely related to the amount of hearing loss present. The results obtained from the conductively impaired listener suggested that this type of hearing loss has no effect on the threshold-duration function, thereby implying that such functions may contribute significantly to the differential diagnosis of auditory disorders.


2016 ◽  
Author(s):  
Martijn Wisselink ◽  
Kittipong Somboonpakdeekun ◽  
Suphawat Kiertkul

1993 ◽  
Vol 28 (11-12) ◽  
pp. 257-261
Author(s):  
M. Truett Garrett ◽  
Zaki Ahmad ◽  
Shelly Young

The recent requirements by U.S.E.P.A. for dechlorination and biomonitoring have increased the importance of automatic control of effluent chlorination in wastewater treatment plants. Difficulties with the Ziegler-Nichols controller tuning procedure were reported at the Kyoto Workshop, 1990. Problems are caused by the noise of incomplete mixing, a long time constant, and the disturbances of changing flow and chlorine demand. The Astrom-Hagglund relay feedback procedure provides acceptable control while data is logged to determine the controller constants. Experiences in using the procedure in existing facilities (not redesigning the mixing point) and the quality of control are presented.


Author(s):  
Tugrul Irmak ◽  
Ksander N. de Winkel ◽  
Daan M. Pool ◽  
Heinrich H. Bülthoff ◽  
Riender Happee

AbstractPrevious literature suggests a relationship between individual characteristics of motion perception and the peak frequency of motion sickness sensitivity. Here, we used well-established paradigms to relate motion perception and motion sickness on an individual level. We recruited 23 participants to complete a two-part experiment. In the first part, we determined individual velocity storage time constants from perceived rotation in response to Earth Vertical Axis Rotation (EVAR) and subjective vertical time constants from perceived tilt in response to centrifugation. The cross-over frequency for resolution of the gravito-inertial ambiguity was derived from our data using the Multi Sensory Observer Model (MSOM). In the second part of the experiment, we determined individual motion sickness frequency responses. Participants were exposed to 30-minute sinusoidal fore-aft motions at frequencies of 0.15, 0.2, 0.3, 0.4 and 0.5 Hz, with a peak amplitude of 2 m/s2 in five separate sessions, approximately 1 week apart. Sickness responses were recorded using both the MIsery SCale (MISC) with 30 s intervals, and the Motion Sickness Assessment Questionnaire (MSAQ) at the end of the motion exposure. The average velocity storage and subjective vertical time constants were 17.2 s (STD = 6.8 s) and 9.2 s (STD = 7.17 s). The average cross-over frequency was 0.21 Hz (STD = 0.10 Hz). At the group level, there was no significant effect of frequency on motion sickness. However, considerable individual variability was observed in frequency sensitivities, with some participants being particularly sensitive to the lowest frequencies, whereas others were most sensitive to intermediate or higher frequencies. The frequency of peak sensitivity did not correlate with the velocity storage time constant (r = 0.32, p = 0.26) or the subjective vertical time constant (r = − 0.37, p = 0.29). Our prediction of a significant correlation between cross-over frequency and frequency sensitivity was not confirmed (r = 0.26, p = 0.44). However, we did observe a strong positive correlation between the subjective vertical time constant and general motion sickness sensitivity (r = 0.74, p = 0.0006). We conclude that frequency sensitivity is best considered a property unique to the individual. This has important consequences for existing models of motion sickness, which were fitted to group averaged sensitivities. The correlation between the subjective vertical time constant and motion sickness sensitivity supports the importance of verticality perception during exposure to translational sickness stimuli.


Sign in / Sign up

Export Citation Format

Share Document