Proton flux measurements from tissues in buffered solution

1995 ◽  
Vol 18 (11) ◽  
pp. 1319-1324 ◽  
Author(s):  
I. ARIF ◽  
I. A. NEWMAN ◽  
N. KEENLYSIDE
2005 ◽  
Vol 23 (9) ◽  
pp. 2975-2982 ◽  
Author(s):  
J. Cabrera ◽  
M. Cyamukungu ◽  
P. Stauning ◽  
A. Leonov ◽  
P. Leleux ◽  
...  

Abstract. The Charged Particle Detector (CPD) on board the Oersted satellite (649 km perigee, 865 km apogee and 96.48° inclination) currently measures energetic protons and electrons. The measured peak fluxes of E>1 MeV electrons are found to confirm the predictions of AE8-MAX, though they occur at a geographical position relatively shifted in the SAA. The fluxes of protons are one order of magnitude higher than the predictions of AP8-MAX in the energy range 20-500 MeV. This huge discrepancy between AP8 and recent measurements in LEO was already noticed and modelled in SAMPEX/PSB97 and TPM-1 models. Nevertheless some other LEO measurements such as PROBA and CORONA-F result in flux values in good agreement with AP8 within a factor 2. The anisotropy of the low-altitude proton flux, combined with measurement performed on board three-axis stabilised satellites, has been suspected to be one possible source of the important discrepancies observed by different missions. In this paper, we evaluate the effect of anisotropy on flux measurements conducted using the CPD instruments. On the basis of the available data, we confirm the inaccuracy of AP8 at LEO and suggest methods to improve the analysis of data in future flux measurements of energetic protons at low altitudes.


2016 ◽  
Author(s):  
Gabriela Villegas ◽  
◽  
Jerry P. Fairley ◽  
Cary R. Lindsey ◽  
Megan M. Aunan ◽  
...  
Keyword(s):  

2020 ◽  
Vol 2020 (12) ◽  
Author(s):  
D. Aristizabal Sierra ◽  
R. Branada ◽  
O. G. Miranda ◽  
G. Sanchez Garcia

Abstract With large active volume sizes dark matter direct detection experiments are sensitive to solar neutrino fluxes. Nuclear recoil signals are induced by 8B neutrinos, while electron recoils are mainly generated by the pp flux. Measurements of both processes offer an opportunity to test neutrino properties at low thresholds with fairly low backgrounds. In this paper we study the sensitivity of these experiments to neutrino magnetic dipole moments assuming 1, 10 and 40 tonne active volumes (representative of XENON1T, XENONnT and DARWIN), 0.3 keV and 1 keV thresholds. We show that with nuclear recoil measurements alone a 40 tonne detector could be as competitive as Borexino, TEXONO and GEMMA, with sensitivities of order 8.0 × 10−11μB at the 90% CL after one year of data taking. Electron recoil measurements will increase sensitivities way below these values allowing to test regions not excluded by astrophysical arguments. Using electron recoil data and depending on performance, the same detector will be able to explore values down to 4.0 × 10−12μB at the 90% CL in one year of data taking. By assuming a 200-tonne liquid xenon detector operating during 10 years, we conclude that sensitivities in this type of detectors will be of order 10−12μB. Reducing statistical uncertainties may enable improving sensitivities below these values.


Sign in / Sign up

Export Citation Format

Share Document