Temporary Pacemaker Treatment in Open Heart Surgery: Pre- to Postoperative Changes in the Electrogram Characteristics

1980 ◽  
Vol 3 (2) ◽  
pp. 150-158 ◽  
Author(s):  
OLE-JORGEN OHM ◽  
ERLING SKAGSETH
2022 ◽  
Vol 30 (1) ◽  
Author(s):  
Malene S. Enevoldsen ◽  
Per Hostrup Nielsen ◽  
J. Michael Hasenkam

Abstract Background To assess the achieved risk and benefits of inserting temporary epicardial pacemaker electrodes after open-heart surgery for potential treatment of postoperative cardiac arrhythmias, and to investigate the extent of its use in clinical practice. Main text A systematic search was conducted in PubMed and repeated in Embase and Scopus using the PRISMA guidelines. The search identified 905 studies and resulted in 12 included studies, where the type of surgery, study design, total number of included patients, number of patients having temporary pacemaker electrodes inserted, number of patients requiring temporary pacing, primary reason for pacing, significant factors predicting temporary pacing, registered complications and study conclusion were assessed. Eight papers concluded that routine insertion of temporary pacemaker electrodes in all postoperative patients is unnecessary. One paper concluded that they should always be inserted, while three papers concluded that pacing is useful in the postoperative period, but did not recommend a frequency of which they should be inserted. Conclusions The literature suggests that the subgroup of younger otherwise healthy patients without preoperative arrhythmia having isolated coronary artery bypass grafting surgery or single valve surgery should not routinely have temporary pacemaker electrodes inserted.


1985 ◽  
Vol 19 (1) ◽  
pp. 39-44 ◽  
Author(s):  
Harald Lindberg ◽  
Jan-Ludvig Svennevig ◽  
Karleif Vatne ◽  
Per Lilleaasen ◽  
Michel Abdelnor

1978 ◽  
Vol 39 (02) ◽  
pp. 474-487 ◽  
Author(s):  
E R Cole ◽  
F Bachmann ◽  
C A Curry ◽  
D Roby

SummaryA prospective study in 13 patients undergoing open-heart surgery with extracorporeal circulation revealed a marked decrease of the mean one-stage prothrombin time activity from 88% to 54% (p <0.005) but lesser decreases of factors I, II, V, VII and X. This apparent discrepancy was due to the appearance of an inhibitor of the extrinsic coagulation system, termed PEC (Protein after Extracorporeal Circulation). The mean plasma PEC level rose from 0.05 U/ml pre-surgery to 0.65 U/ml post-surgery (p <0.0005), and was accompanied by the appearance of additional proteins as evidenced by disc polyacrylamide gel electrophoresis of plasma fractions (p <0.0005). The observed increases of PEC, appearance of abnormal protein bands and concomitant increases of LDH and SGOT suggest that the release of an inhibitor of the coagulation system (similar or identical to PIVKA) may be due to hypoxic liver damage during extracorporeal circulation.


1967 ◽  
Vol 18 (03/04) ◽  
pp. 634-646 ◽  
Author(s):  
N Thurnherr

SummaryBlood clotting investigations have been executed in 25 patients who have undergone open heart surgery with extracorporeal circulation. A description of alterations in the activity of blood clotting factors, the fibrinolytic system, prothrombin consumption and platelets during several phases of the operation is given.


2007 ◽  
Vol 55 (S 1) ◽  
Author(s):  
N Madershahian ◽  
T Wittwer ◽  
J Strauch ◽  
J Wippermann ◽  
UFW Franke ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document