Voxel-Based Morphometry and Voxel-Based Relaxometry in Parkinsonian Variant of Multiple System Atrophy

2009 ◽  
Vol 20 (3) ◽  
pp. 260-266 ◽  
Author(s):  
Loukia C. Tzarouchi ◽  
Loukas G. Astrakas ◽  
Spyridon Konitsiotis ◽  
Sofia Tsouli ◽  
Persefoni Margariti ◽  
...  
NeuroImage ◽  
2005 ◽  
Vol 25 (1) ◽  
pp. 287-293 ◽  
Author(s):  
Karsten Specht ◽  
Martina Minnerop ◽  
Jonas Müller-Hübenthal ◽  
Thomas Klockgether

2006 ◽  
Vol 21 (2) ◽  
pp. 159-165 ◽  
Author(s):  
Christian Brenneis ◽  
Sylvia M. Boesch ◽  
Karl E. Egger ◽  
Klaus Seppi ◽  
Christoph Scherfler ◽  
...  

2021 ◽  
Author(s):  
Sara Ponticorvo ◽  
Renzo Manara ◽  
Maria Claudia Russillo ◽  
Roberto Erro ◽  
Marina Picillo ◽  
...  

Abstract Diagnosis of multiple system atrophy (MSA) may be improved by using multimodal imaging approaches. We investigated the use of T1-weighted/T2-weighted (T1w/T2w) images ratio combined with voxel-based morphometry to evaluate brain tissue integrity in MSA compared to Parkinson’s disease (PD) and healthy controls (HC). Twenty-six patients with MSA, 43 patients with PD and 56 HC were enrolled. Whole brain voxel-based and local regional analyses were performed to evaluate gray and white matter (GM and WM) tissue integrity and mean regional values were used for patients classification using logistic regression. Increased mean regional values of T1w/T2w in bilateral putamen were detected in MSA-P compared to PD and HC. The combined use of regional GM and T1w/T2w values in the right and left putamen showed the highest accuracy in discriminating MSA-P from PD and good accuracy in discriminating MSA from PD and HC. A good accuracy was also found in discriminating MSA from PD and HC by either combining regional GM and T1w/T2w values in the cerebellum or regional WM and T1w/T2w in the cerebellum and brainstem. The T1w/T2w image ratio alone or combined with validated MRI parameters can be further considered as a potential candidate biomarker for differential diagnosis of MSA.


Author(s):  
Junya Ebina ◽  
Kazuhiro Hara ◽  
Hirohisa Watanabe ◽  
Kazuya Kawabata ◽  
Fumio Yamashita ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
S. Ponticorvo ◽  
R. Manara ◽  
M. C. Russillo ◽  
R. Erro ◽  
M. Picillo ◽  
...  

AbstractDiagnosis of multiple system atrophy (MSA) may be improved by using multimodal imaging approaches. We investigated the use of T1-weighted/T2-weighted (T1w/T2w) images ratio combined with voxel-based morphometry to evaluate brain tissue integrity in MSA compared to Parkinson’s disease (PD) and healthy controls (HC). Twenty-six patients with MSA, 43 patients with PD and 56 HC were enrolled. Whole brain voxel-based and local regional analyses were performed to evaluate gray and white matter (GM and WM) tissue integrity and mean regional values were used for patients classification using logistic regression. Increased mean regional values of T1w/T2w in bilateral putamen were detected in MSA-P compared to PD and HC. The combined use of regional GM and T1w/T2w values in the right and left putamen showed the highest accuracy in discriminating MSA-P from PD and good accuracy in discriminating MSA from PD and HC. A good accuracy was also found in discriminating MSA from PD and HC by either combining regional GM and T1w/T2w values in the cerebellum or regional WM and T1w/T2w in the cerebellum and brainstem. The T1w/T2w image ratio alone or combined with validated MRI parameters can be further considered as a potential candidate biomarker for differential diagnosis of MSA.


2003 ◽  
Vol 60 (10) ◽  
pp. 1431 ◽  
Author(s):  
Karsten Specht ◽  
Martina Minnerop ◽  
Michael Abele ◽  
Jürgen Reul ◽  
Ullrich Wüllner ◽  
...  

2003 ◽  
Vol 18 (10) ◽  
pp. 1132-1138 ◽  
Author(s):  
Christian Brenneis ◽  
Klaus Seppi ◽  
Michael F. Schocke ◽  
Jörg Müller ◽  
Elisabeth Luginger ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document