Age-related changes in central corneal thickness and corneal endothelial characteristics

2013 ◽  
Vol 91 ◽  
pp. 0-0
Author(s):  
S GALGAUSKAS ◽  
D NORVYDAITė ◽  
S STECH ◽  
R ASOKLIS
Cornea ◽  
2009 ◽  
Vol 28 (2) ◽  
pp. 136-139 ◽  
Author(s):  
Remzi Karadag ◽  
Ahmet Sen ◽  
Haydar Golemez ◽  
Hikmet Basmak ◽  
Nilgun Yildirim ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Xi Feng ◽  
Yong Wang ◽  
Jianheng Liang ◽  
Yali Xu ◽  
Julio Ortega-Usobiaga ◽  
...  

Objective. This study aimed to analyze the distribution of lens thickness (LT) and its associations in age-related cataract patients based on swept-source optical coherence tomography (SS-OCT). Methods. This cross-sectional study included 59,726 Chinese age-related cataract patients. Only right-eye data were included in the study. Repeated measures of ocular parameters were performed using an IOL Master 700 device. The distributions of ocular biometric data including anterior chamber depth (ACD), LT, axial length (AL), central corneal thickness (CCT), white-to-white (WTW), and mean keratometry (MK) and their associations with age were assessed. The anterior segment (AS) was measured as the sum of CCT, ACD, and LT, while the vitreous chamber depth (VCD) was calculated as the difference between AL and AS. The values of LT : AL, AS : AL, and VCD : AL in different AL groups and their changes are the main outcome measures used to observe the proportion of the anterior and posterior segments of the eye. Results. Biometric data were available for 59,726 individuals. The mean age was 68.81 years (range = 40–100); 40.62% were male and 59.38% were female. Mean anterior chamber depth (ACD) was 3.02 ± 0.44 mm, mean LT was 4.51 ± 0.44 mm, mean axial length (AL) was 23.89 ± 1.92 mm, mean central corneal thickness (CCT) was 0.53 ± 0.03 mm, mean white-to-white (WTW) was 11.64 ± 0.44 mm, and mean keratometry (MK) was 44.27 ± 1.65 diopter. Female patients had shorter AL, shallower ACD, smaller CCT and WTW, decreased LT, and steeper corneas ( p  < 0.005). ACD revealed the strongest negative correlation ( p  ≤ 0.001, r = –0.682) with LT. Age ( p  ≤ 0.001, r = 0.348) showed a moderate positive correlation, whereas MK ( p  < 0.05, r = 0.011), CCT ( p  ≤ 0.001, r = 0.041) had a weak positive correlation and WTW ( p  ≤ 0.001, r = –0.034) had a weak negative correlation with LT. A nonlinear correlation was found between LT and AL. LT increased with age in both males and females. LT changed variably in eyes with AL less than 27 mm, LT decreased as AL increased, then LT gradually increased as AL increased in extremely long and extra-long eyes ( p  ≤ 0.001). LT : AL and AS : AL decreased as AL increased, VCD : AL gradually increased as AL increased in highly myopic eyes, and VCD : AL increased by about 0.01 for every 1 mm increase in AL. Conclusions. Among Chinese age-related cataract patients, we found LT to have the strongest relation with ACD. The lens was thicker in elderly patients and women. The correlation between LT and AL is not a simple negative correlation; with the increase of age, LT decreases first and then increases. The proportion of VCD is constantly rising with the elongation of AL.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ahmet Colakoglu ◽  
Iffet Emel Colakoglu ◽  
Cemile Banu Cosar

AbstractTo determine the use of differential pressure difference (DPD), in air-puff differential tonometry, as a potential biomechanical measure of the cornea and elucidate its relationship with the intraocular pressure (IOP), central corneal thickness, corneal curvature, and age. This study comprised 396 eyes from 198 patients and was conducted at Acibadem University, School of Medicine, Department of Ophthalmology, Istanbul, Turkey. The central corneal curvature and refraction of the eyes were measured using an Auto Kerato-Refractometer (KR-1; Topcon Corporation, Tokyo, Japan). IOP and central corneal thickness were measured using a tono-pachymeter (CT-1P; Topcon Corporation, Tokyo, Japan), wherein two separate readings of IOP were obtained using two different modes: 1–30 and 1–60. The difference between these two readings was recorded as the DPD. The factors affecting the DPD were determined by stepwise multiple linear regression analysis. DPD varied over a dynamic range of − 3.0 to + 5.0 mmHg and was weakly correlated with the central corneal thickness (r = 0.115, p < 0.05). DPD showed no significant correlation with IOP 1–30 (p > 0.05). A weak but statistically significant (p < 0.05) positive correlation of DPD was observed with age (r = 0.123), Kavg (r = 0.102), and the CCT (r = 0.115). There was a significant correlation between DPD and Kavg, CCT, and age. There was no significant correlation between DPD and IOP 1–30. Age-related changes in the corneal ultrastructure may be a plausible explanation for the weak positive association between age and DPD. The proposed method may prove a valid non-invasive tool for the evaluation of corneal biomechanics and introduce DPD in the decision-making of routine clinical practice.


Cornea ◽  
2007 ◽  
Vol 26 (1) ◽  
pp. 1-5 ◽  
Author(s):  
Florian Rüfer ◽  
Anke Schröder ◽  
Christine Bader ◽  
Carl Erb

2013 ◽  
pp. 1445 ◽  
Author(s):  
Saulius Galgauskas ◽  
Dovile Norvydaite ◽  
Dalia Krasauskaite ◽  
Simona Stech ◽  
Rimvydas Stanislovas Ašoklis

Cornea ◽  
2007 ◽  
Vol 26 (2) ◽  
pp. 182-184 ◽  
Author(s):  
George D Kymionis ◽  
Theoni D Panagiotoglou ◽  
Sonia H Yoo ◽  
Nikolaos S Tsiklis ◽  
Emmanouel Christodoulakis ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-11 ◽  
Author(s):  
Haixia Zhang ◽  
Xiao Qin ◽  
Xiaomeng Cao ◽  
Di Zhang ◽  
Lin Li

Purpose. To study the variations in corneal clinical biomechanical parameters (CCBP) and corneal geometrical parameters of rabbit in relation to age. Methods. Rabbits aged 3, 7, 12, 18, and 24 months were enrolled. Each eye of the rabbits was tested with Ocular Response Analyzer (ORA), Optical Coherence Tomography (OCT), and Pachymeter to obtain the intraocular pressure (IOP): Goldmann-correlated IOP (IOPg) and Corneal Compensated Intraocular Pressure (IOPcc); CCBP: Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF); corneal geometric parameters: corneal curvature radius (CCR) and central corneal thickness (CCT). Results. The IOP of the rabbits changes slightly from 3 to 7 months of age, while it significantly decreases from 7 to 18 months of age and increases from 18 to 24 months of age; CH and CRF decrease with the increase of age; CCT increases from 7 to 18 months and decreases from 3 to 7 months of age and from 18 to 24 months of age; CCR presents an upward trend from 3 to 18 months and a significant decrease between 18 and 24 months of age. Conclusion. CH and CRF are negatively correlated with age. CCT and CCR are positively correlated with age.


2017 ◽  
Vol 2017 ◽  
pp. 1-8
Author(s):  
Yingmei Li ◽  
Zhentao Fu ◽  
Jian Liu ◽  
Miao Li ◽  
Yuguang Zhang ◽  
...  

Purpose. To describe corneal endothelial characteristics, central corneal thickness, and intraocular pressure in a population of Chinese age-related cataract patients and to determine the effects of age, gender, hypertension, and body mass index (BMI). Methods. 1551 eyes were examined preoperatively. The parameters measured were endothelial cell density (CD), average cell area (CA), coefficient of variation (CV), cell hexagonality (HEX), central corneal thickness (CCT), intraocular pressure (IOP), and axial length (AL). Results. There were significant differences in CV and BMI between genders. There was a significant decrease in CD, CCT, and IOP and, conversely, an increase in CA and BMI with increasing age. The patients who suffered from hypertension had bigger CA, less CD, and lower HEX than the patients who did not suffer from hypertension. CD has a negative correlation with age and CV and a positive correlation with CCT, CCT has a positive association with CD and IOP, and IOP had a negative relationship with age and a positive relationship with CCT, CA, and HEX. Conclusions. Normative data for the corneal endothelium, central corneal thickness, and intraocular pressure in the normal age-related cataract patients are reported which will serve as a baseline for comparative studies about cataract.


Sign in / Sign up

Export Citation Format

Share Document