scholarly journals Effects of a dual‐filter‐based cerebral embolic protection device in transcatheter aortic valve replacement on cerebral oxygen saturation: A prospective pilot study

Author(s):  
Stephanie Voss ◽  
Annick Ernst ◽  
Magdalena Erlebach ◽  
Hendrik Ruge ◽  
Konstantinos Sideris ◽  
...  
2019 ◽  
Vol 68 (07) ◽  
pp. 616-622
Author(s):  
Stephanie Voss ◽  
Marcus-André Deutsch ◽  
Johanna Schechtl ◽  
Magdalena Erlebach ◽  
Konstantinos Sideris ◽  
...  

Abstract Background There is a growing use of cerebral protection devices in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to analyze if the use of these devices itself has an impact on the complexity and the risk of TAVR. Methods Between February 2016 and July 2017, 391 patients underwent transfemoral TAVR with Medtronic CoreValve Evolut R (n = 196) or Edwards Sapien 3 (n = 195). In 39 patients, the Claret Sentinel™ embolic protection device (CS-EPD) was used. Prospectively collected data were retrospectively analyzed, comparing fluoroscopy/operation time, amount of contrast used, vascular events, and postprocedural renal function in TAVR patients with (n = 39) and without (n = 352) CS-EPD. Results The CS-EPD was placed through the right radial (n = 35) or brachial (n = 4) artery. Procedural success rate defined as correct deployment and retraction of both filters was 94.9%. No device-related vascular complications occurred. TAVR patients with CS-EPD showed a significantly higher total operation time, total fluoroscopy time, and amount of used contrast (85.4 ± 39.3 vs. 64 ± 29.8 minutes, p = 0.002; 20.7 ± 9.3 vs. 13.7 ± 7 minutes, p ≤ 0.001; 133.7 ± 42.6 vs. 109.7 ± 44.5 mL, p = 0.001). Comparing the initial third of patients receiving a CS-EPD with the last third of CS-EPD cases, procedural time had decreased significantly (102.5 ± 34.9 vs. 67 ± 11.9; p = 0.002). There were no differences in postprocedural renal failure (p = 0.80). Conclusion Our data add evidence that the application of the CS-EPD is not associated with an additional risk for the patient. Although procedural time and amount of contrast are still higher when using the CS-EPD, there were no device-related complications or increased incidence of renal failure.


Author(s):  
Oliver Abela

An 80-year-old woman with a history of surgical aortic valve replacement with a 21 mm St. Jude Medical Biocorporcine aortic valve 14 years prior presented with New York Heart Association (NYHA) class III symptoms, severeaortic insufficiency from a degenerated prosthesis, and a large echocardiographic mobile mass representing a highlymobile prosthetic leaflet. The patient worsened to NYHA class IV symptoms despite medical management. The Societyof Thoracic Surgery mortality risk score was extremely high. However, a valve-in-valve transcatheter aortic valve replacement (TAVR) was found to be a reasonable option. We used a 20 mm SAPIEN 3 Ultra value (Edwards Lifesciences Inc., Irvine, CA, USA) with a SENTINEL embolic protection device (Boston Scientific, Marlborough, MA, USA). During valve deployment, the echocardiographic mobile mass was visually pinned between the new TAVR valve and the surgical bioprosthetic valve. No large embolic debris was noted within the embolic protection device, and the patient remained without any new focal neurologic deficits in the perioperative period and at the 30-day follow-up. The severe aortic insufficiency resolved, and the patient clinically improved to NYHA class II symptoms.


Sign in / Sign up

Export Citation Format

Share Document