Transcranial Doppler as a Screening Tool for High‐Risk Patent Foramen Ovale in Cryptogenic Stroke

2020 ◽  
Author(s):  
Seongho Park ◽  
Jin Kyung Oh ◽  
Jae‐Kwan Song ◽  
Boseong Kwon ◽  
Bum Joon Kim ◽  
...  
Stroke ◽  
2019 ◽  
Vol 50 (Suppl_1) ◽  
Author(s):  
Seongho Park ◽  
Jin Kyung Oh ◽  
Jae-Kwan Song ◽  
Boseong Kwon ◽  
Jong S. Kim ◽  
...  

2018 ◽  
Vol 71 (20) ◽  
pp. 2335-2342 ◽  
Author(s):  
Pil Hyung Lee ◽  
Jae-Kwan Song ◽  
Jong S. Kim ◽  
Ran Heo ◽  
Sahmin Lee ◽  
...  

Cephalalgia ◽  
2006 ◽  
Vol 26 (8) ◽  
pp. 934-939 ◽  
Author(s):  
FJ Carod-Artal ◽  
L da Silveira Ribeiro ◽  
H Braga ◽  
W Kummer ◽  
HM Mesquita ◽  
...  

The aim of this study was to investigate the prevalence of patent foramen ovale (PFO) in a consecutive unselected cohort of migraine patients (with and without aura) and compare it with a group of ischaemic young and elderly stroke patients. One hundred and forty-one migraine patients were compared with 330 stroke patients (130 young patients; 200 elderly patients) selected from our hospital stroke data bank. PFO was assessed with transcranial Doppler sonography with i.v. injection of agitated saline. The prevalence of PFO was 51.7± in migraine with aura (MA) patients, 33.7± in migraine without aura (MoA) patients, 33.8± in young stroke patients and 20.5± in elderly stroke patients ( P < 0.001). The prevalence of PFO in cryptogenic stroke in young and elderly stroke patients was, respectively, 41.1± and 25± ( P = 0.04). The difference between MA and MoA patients was significant (odds ratio = 2.1). The prevalence of PFO in MA patients is higher than in MoA patients and in young cryptogenic stroke patients.


2021 ◽  
Author(s):  
Yoichi Takaya ◽  
Rie Nakayama ◽  
Teiji Akagi ◽  
Fumi Yokohama ◽  
Takashi Miki ◽  
...  

Abstract Transcatheter closure of patent foramen ovale (PFO) is an effective therapy for preventing cryptogenic stroke (CS). The identification of high-risk PFO, which is more likely to be linked to CS, is essential. This study aimed to assess the accuracy of contrast transthoracic echocardiography (TTE) for evaluating large right-to-left (RL) shunt. We enrolled 119 patients with or without CS who were confirmed to have PFO. The severity of RL shunt evaluated by contrast TTE and transesophageal echocardiography (TEE) was classified as follows: small (<10 microbubbles), moderate (10–20 microbubbles), and large (>20 microbubbles). With contrast TTE, large RL shunt was observed in 94 (79%) of 119 patients, including 66 of 74 with CS and 28 of 45 without CS. With contrast TEE, large RL shunt was observed in 33 (28%) patients, including 26 with CS and 7 without CS. Contrast TTE showed large RL shunt more frequently than contrast TEE (p < 0.01). Large RL shunt evaluated by contrast TTE had a sensitivity of 89% and an accuracy of 70% for the association with CS, whereas large RL shunt evaluated by contrast TEE had a sensitivity of 35% and an accuracy of 56%. Accuracy was significantly greater in contrast TTE than in contrast TEE (p = 0.02). In conclusion, contrast TTE identified large RL shunt more frequently. Large RL shunt evaluated by contrast TTE provided greater accuracy for the association with CS. Our findings suggest that contrast TTE is valuable for evaluating large RL shunt as high-risk PFO.


2020 ◽  
Vol 128 (3) ◽  
pp. 296-306
Author(s):  
Igor F. Palacios

A patent foramen ovale (PFO) is a highly prevalent structure among the adult population. It allows the shunt of blood through the inter-atrial septum and has been associated with cryptogenic stroke, transient ischemic attack, significant right to left shunting resulting in resting and exercise-induced hypoxemia, platypnea orthodeoxia syndrome, and decompression sickness after scuba diving and migraines. Currently, transthoracic and transesophageal echocardiography and transcranial Doppler are the most important diagnostic tools, for the diagnosis of PFO. The sensitivity and specificity of the study depend on the modalities available: transthoracic (TTE), transesophageal (TEE), and transcranial Doppler (TCD), as well as the intravenous use of agitated saline and the site of injection.


2010 ◽  
Vol 63 (7-8) ◽  
pp. 445-449
Author(s):  
Zeljko Zivanovic ◽  
Svetlana Ruzicka-Kaloci ◽  
Aleksandar Jesic ◽  
Biljana Radovanovic ◽  
Aleksandra Lucic-Prokin ◽  
...  

A patent foramen ovale has been reported to be more frequently detected in cryptogenic stroke, with paradoxical embolism as the major pathogenetic mechanism. The standard procedure for the detection of a patent foramen ovale is transesophageal echo?cardiography. Transcranial Doppler sonography with bubble test is almost as reliable as transesophageal echocardiography. Seventeen patients with acute ischemic stroke and transient ischemic attacks hospitalized at the Department of Neurology in Novi Sad underwent examinations to detect a patent foramen ovale, which was found in 55.6% of patients with cryptogenic stroke. The average age of these patients was 30.6 years. Transcranial Doppler sonography showed 100% sensitivity and 100% specificity for the predicti?on of right-to-left shunts proven by transesophageal contrast echocardiography. Both positive and negative predictive values in our group of patients were 1. Transcranial Doppler with bubble test is a reliable method for the detection of a patent foramen ovale, with a high level of sensitivity and specificity which is comparable with transesophageal echocardiography. Moreover, it is cheaper and more comfortable than transesophageal echocardiography, and should be used routinely in neurological practice.


2018 ◽  
Vol 35 (2) ◽  
pp. 127-133
Author(s):  
Madison B. Stafford ◽  
Jennifer E. Bagley ◽  
Dora DiGiacinto

The correlation between cryptogenic stroke and patent foramen ovale is high in young patients. Currently, transesophageal echocardiography is the gold standard for detection. However, it is invasive and limits Valsalva maneuvers. This article reviews the diagnostic accuracy of the three modalities: transthoracic echocardiography, transesophageal echocardiography, and transcranial Doppler. The results suggest that transcranial Doppler sonography is an accurate, easily accessible procedure for detecting patent foramen ovale and should be considered an excellent alternative to transthoracic or transesophageal echocardiography. Transesophageal echocardiography is still necessary for patients who require treatment. The combination of transcranial Doppler and transesophageal echocardiography provides the highest level of information regarding the complete diagnosis of patent foramen ovales.


Author(s):  
Yoichi Takaya ◽  
Rie Nakayama ◽  
Teiji Akagi ◽  
Fumi Yokohama ◽  
Takashi Miki ◽  
...  

Background: Transcatheter closure of patent foramen ovale (PFO) is an effective therapy for preventing cryptogenic stroke (CS). The identification of high-risk PFO, which is more likely to be linked to CS, is essential. This study aimed to assess the accuracy of contrast transthoracic echocardiography (TTE) for evaluating large right-to-left (RL) shunt. Methods: We enrolled 119 patients with or without CS who were confirmed to have PFO. The severity of RL shunt evaluated by contrast TTE and transesophageal echocardiography (TEE) was classified as follows: small (<10 microbubbles), moderate (10–20 microbubbles), and large (>20 microbubbles). Results: With contrast TTE, large RL shunt was observed in 94 (79%) of 119 patients, including 66 of 74 with CS and 28 of 45 without CS. With contrast TEE, large RL shunt was observed in 33 (28%) patients, including 26 with CS and 7 without CS. Contrast TTE showed large RL shunt more frequently than contrast TEE (P < .01). Large RL shunt evaluated by contrast TTE had a sensitivity of 89% and an accuracy of 70% for the association with CS, whereas large RL shunt evaluated by contrast TEE had a sensitivity of 35% and an accuracy of 56%. Accuracy was significantly greater in contrast TTE than in contrast TEE (P = .02). Conclusion: Contrast TTE identified large RL shunt more frequently. Large RL shunt evaluated by contrast TTE provided greater accuracy for the association with CS. Our findings suggest that contrast TTE is valuable for evaluating large RL shunt as high-risk PFO.


Sign in / Sign up

Export Citation Format

Share Document