doppler sonography
Recently Published Documents


TOTAL DOCUMENTS

2392
(FIVE YEARS 128)

H-INDEX

80
(FIVE YEARS 3)

Author(s):  
Aysel MILANLIOGLU ◽  
Aslı YAMAN ◽  
Mehmet KOLUKISA ◽  
Talip ASIL

ABSTRACT Background: Carotid artery stenosis increases cerebral ischemic event risk through changing different cerebral hemodynamic parameters. Objective: To investigate how cerebral hemodynamics in the M1 segment of middle cerebral artery change in patients with carotid artery stenosis, after motor tasks using transcranial Doppler sonography (TCD). Methods: Thirty-two healthy subjects and 30 patients with unilateral symptomatic carotid artery stenosis were recruited. The patient population was divided into three groups according to the degree of stenosis (group 1: ≥50 to 69%, group 2: 70 to 89% and group 3: ≥90 to 99%). TCD was used to measure the pulsatility index (PI) and cerebral vasomotor reactivity (CVR). Results: In the patient group, significant differences for symptomatic side PI values (p=0.01) and mean CVR increases (p=0.05) were observed, compared with the healthy controls. However, the difference was not statistically significant for asymptomatic side PI values and mean CVR increases. The results from the intergroup comparison showed significantly higher percentages of symptomatic and asymptomatic side CVR increases in group 1, compared with groups 2 and 3 (p=0.001 and p=0.002, respectively). Conclusions: Our study showed that cerebral autoregulation and hemodynamic mechanisms are impaired in patients with carotid artery stenosis. Furthermore, the impairment of PI and CVR tends to get worse with increasing degrees of stenosis. In addition, this study demonstrated that assessment of these two hemodynamic parameters in clinical practice might be helpful for monitoring the progress of carotid artery stenosis.


2021 ◽  
Vol 50 (3) ◽  
pp. 66-69
Author(s):  
D. A. Niauri ◽  
A. F. Harutyunyan

The state of regional blood flow in 65 patients before and after endoscopic myomectomy was studied using modem methods such as Doppler examination and color Doppler sonography. It was determined that blood flow velocity indeces obtained during the Doppler examination of myoma vessels and uterine arteries allow to estimate the morphological structure of myomas uninvasively and can be used to define the indications for conservative endoscopic surgical procedures in patients with myoma uteri. Doppler monitoring of regional blood flow during postoperative period makes it possible to evaluate the effectiveness of surgical treatment previously performed.


2021 ◽  
Vol 12 (4) ◽  
pp. 6-11
Author(s):  
E. V. Bashirov ◽  
V. A. Krutova ◽  
I. I. Kutsenko

Objective: To assess the diagnostic value of biomarkers: microbiological, molecular and biological, immunological biomarkers, characteristic of various types of recurrent myoma-associated growth.Materials and Methods: Seventy women of reproductive age with recurrent uterine myoma and its combination with adenomyosis after conservative treatment in the Clinic of Kuban State Medical University were examined. Methods: microbiological examination, sonography, Doppler sonography, histology, immunohistochemistry, morphometry.Results: The type of recurrent myoma-associated growth was proved to be dependent on molecular and biological characteristics of tumors, the presence of infection and blood perfusion. It was indicated that women with recurrence of myoma-associated growth of a “false” type were characterized by high rates of infections (the presence of reproductive losses, chronic inflammatory diseases of the pelvic organs) and significant bacterial contamination of the genital tract biotopes. Blood perfusion features were identified for true and “false” types of recurrent myoma-associated growth based on Doppler sonography data, which were consistent with features of tumor vessel morphometry. Analysis of uterine myoma histological types and their vascularization features showed correlation of forms with a high proliferative potential of a tumor on a molecular and cellular level to moderate and high expression of steroid hormone receptors in combination with Ki67, a significant diameter of the lumen of the vessels with the highest VI and VFI values.Conclusions: A comprehensive study of women with uterine hyperplasia determines the possibility of prediction of pathogenetic variants of recurrent myoma-associated tissue growth and adequate choice of treatment options and rehabilitation course.


2021 ◽  
Author(s):  
Zhiming Li ◽  
Shunli Liu ◽  
Tingfei Yan ◽  
Yabin Hu ◽  
Chuanyu Zhang ◽  
...  

Abstract Purpose: To investigate the clinical feasibility of diagnosing and classifying patent foramen ovale (PFO) in patients with cerebral disorders by cardiac cine MRI (CCMRI) without contrast.Materials and Methods: Forty-four patients (24 males and 20 females; mean age, 41.3 years; range, 21–64 years) with cerebral disorders underwent contrast transcranial Doppler sonography (cTCD) and non-enhanced CCMRI examinations between October 2019 and March 2020. CCMRI was performed with a 3.0T magnetic resonance (MR) scanner using the OBL FIESTA CINE 4CH sequence. The scanning direction was perpendicular to the interatrial septum (IAS). The obtained MR images were analyzed by AW station 4.4. Pseudo-color coding was performed based on the different phases. The blood shunt condition was observed and recorded, noting the PFO length and width and whether it was complicated by IAS aneurysm or secondary septum thickening.Results: Thirty-nine of the 44 patients with cerebral disorders were confirmed to have right-to-left shunt by cTCD, and 37 of them were diagnosed with PFO by CCMRI. Two of the five remaining patients were also diagnosed with PFO by CCMRI. Compared with cTCD as a standard, CCMRI assessment resulted in the following: sensitivity, 94.9%; specificity, 60.0%; accuracy, 90.9%; positive predictive value, 94.9%; negative predictive value, 60.0%; area under the curve, 0.774. Using pseudo-color coding, a right-to-left color jet was observed in 34 patients, and a two-way shunt was found in five. IAS aneurysm and secondary septum thickening were found in five and three patients (11.4% and 6.8%), respectively. The maximum PFO diameters ranged from 1.7 to 16.8 mm, and the mean diameter was 5.4 ± 3.4 mm.Conclusion: The noninvasive CCMRI without contrast proved an excellent method for PFO identification, evaluation, and classification, with high sensibility (92.85%) and concordance (90.9%) compared to cTCD.


2021 ◽  
Vol 8 (09) ◽  
pp. 5615-5620
Author(s):  
Pratima Rani Biswas ◽  
Gautom Kumar Paul ◽  
Mahmuda Khatun ◽  
Mamata Manjuri ◽  
Samima Rahman

Objective: To examine the diagnostic value of umbilical artery velocity waveforms for the early detection of pregnancy induced hypertension and fetal growth restriction. To determine the utility of color Doppler Sonography of the fetoplacetal circulation for early detection of high risk pregnancies. Methods: This prospective study was conducted in the Department of Obstetrics & Gynecology, Sir Sallimullah Medical Collage & Mitford Hospital Dhaka in collaboration with radiology and imaging department of Dhaka hospital in 1st July, 2006 to 30 June, 2008. 126 randomly selected patients from 17-35 years of ages whose umbilical artery Doppler sonography was done between 16-22 weeks of gestation.  All the patient were taken umbilical artery Doppler ultrasonography. Informed consent was taken from all patients. Results: A total 126 subjects of 16 to 22 weeks of gestation were included in this series. On application of the student‘t’ test for S/D ratio between normal and abnormal waveforms of the umbilical artery was found significant difference (P<.0001). Distribution of patient according to umbilical artery systolic / diastolic ratio (n=126). Normal UA waveform 76 (60%), abnormal UA waveform 50(40%), Age (Mean ±SD) in year, normal UA waveform 25.63 ± 4.47 and abnormal UA waveform 25.86±3.75. Para: Primiparous normal UA waveform 36 (60%) & abnormal UA waveform 24 (40%), multiparous normal UA waveform 40 (60.6%) & abnormal UA waveform 26 (39.4%). Gestation age at scan in weeks (Mean± SD), normal UA waveform 19.5 ±2.5, abnormal UA waveform 19±2.0. Gestation age at delivery in weeks (Mean± SD), normal UA waveform 39.03±1.61, abnormal UA waveform 35.78 ±1.53, P value 0.0001. Birth wt. in Kg. (Mean ±SD), normal UA waveform 3.10 ±0.38, abnormal UA waveform 2.42 ±0.53, P value 0.0001. S/D ratio (Mean ±SD), normal UA waveform 2.40 ±0.31, abnormal UA waveform 5.46±1.62, P value 0.0001. Cases with an abnormal outcome in relation to whether the umbilical artery waveform was classified as normal or abnormal (n=126). Abnormal outcome in PIH normal UA waveform (n=76) 4%, PIH abnormal UA waveform (n=50) 14%, P value 0.001. In PIH/FGR, normal UA waveform (n=76) 1% & abnormal UA waveform (n=50) 5%, P value 0.024. FGR normal UA waveform (n=76) 5% & abnormal UA waveform (n=50) 13%, P value 0.002. Asphyxia normal UA waveform (n=76) 0% & abnormal UA waveform (n=50) 3%, P value 0.017. PIH /IUD normal UA waveform (n=76) 0% & abnormal UA waveform (n=50) 1%.   A significant association was found when the Chi Square (X 2) test was used to examine the relationship between umbilical artery blood flow and the outcome of patient (i.e FGR, PIH, fetal asphyxia). The screening test had a sensitivity of 78.26% & specificity of 82.5% and accuracy 80.95%. The predictive value of a positive test was 72% and of a negative test 86.84%. Conclusion : A close linear relationship between diagnosis of high risk pregnancy & umbilical artery Doppler velocity waveforms was observed .As umbilical artery Doppler is easy to perform and it is done in between 16 to 22 weeks of gestation can be done along with anomaly scan which is also done at 20-22 week of gestation. So, UA Doppler does not cause additional USG scan. Along with anomaly scan UA Doppler will help to screen out high risk pregnancy.


Author(s):  
E.M. Jung ◽  
S. Kammerer ◽  
M. Brandenstein ◽  
F.J. Putz ◽  
C. Stroszczynski ◽  
...  

AIM: To evaluate the possibilities of flow detection using high resolution flow (HR Flow) and Glazing Flow technique in patients with liver parenchymal changes and flow changes in comparison to colour coded Doppler sonography (CCDS) MATERIAL AND METHODS: All examinations were performed using a multi frequency matrix convex probe with high resolution technique (SC6-1U/Resona7, Mindray, Shenzhen, China) by one experienced examiner to evaluate the venous, portal venous and arterial liver flow with digital documentation of the dynamic flow parameters like peak systolic flow, end-diastolic flow and resistance index. For liver parenchymal stiffness changes shear wave elastography was performed with at least 10 measurements. By independent readers an elevation was performed to evaluate the image quality and the degree of flow artefacts, from 0 = not available to 5 points with excellent image quality without flow artefacts. RESULTS: All 40 patients (24 men, 16 women, age 27–83 years, mean 56±5 years) showed morphology changes from B-Mode of the liver parenchyma to inhomogeneous tissue with higher stiffness evaluated by the shear wave elastography (1.45 m/s up to 2.79 m/s±1.79 m/s, considering F1 up to F4 fibrosis) and in 15 cases histopathologically proven liver cirrhosis. In 9 cases after non-acute thrombosis flow reduction of the portal vein was the reason for the diameter less than 5 mm. Flow parameters for the venous flow were between 8 cm/s up to 29 cm/s, mean 14±4 cm/s, for the hepatic portal vein 5 cm/s up to 57 cm/s, mean 17±5 cm/s, for the hepatic artery systolic flow between 50 cm/s up to 127±33 cm/s, end-diastolic flow from 22 cm/s up to 47 cm/s±8 cm/s. Resistance index for the hepatic artery was between 0.41 up to 0.73, mean 0.67±0.25. The image quality for CCDS over all cases was evaluated for CCDS between 1 up to 4. The mean quality was 2.5±0.5, for HR Flow in combination with Glazing flow 3±0.5, with significant differences for the 2 readers (P <  0.01). CONCLUSION: Combination of HR Flow with Glazing Flow could be helpful to evaluate morphological und hemodynamic changes of liver arterial flow, portal venous flow and venous flow. Reduction of flow artefacts in combination with a higher image quality could be helpful for optimizing the digital measurements also for follow up examinations.


Sign in / Sign up

Export Citation Format

Share Document