A comparison between the v-gel supraglottic airway device and the cuffed endotracheal tube for airway management in spontaneously breathing cats during isoflurane anaesthesia

2013 ◽  
Vol 40 (3) ◽  
pp. 265-271 ◽  
Author(s):  
Hugo van Oostrom ◽  
Maximillian W Krauss ◽  
Robert Sap
2019 ◽  
Author(s):  
James Peyton ◽  
Raymond Park

Airway management in children is usually very straightforward. Unfortunately, when it is not straightforward complications associated with problems encountered while managing the airway can be life-threatening. Airway management can be considered to consist of several different techniques for oxygenating and ventilating an anesthetized patient, namely mask ventilation, supraglottic airway device ventilation, and tracheal intubation. This chapter discusses these techniques and the factors associated with difficulty in performing them. There are anatomic features associated with difficulty in all of these techniques that are caused by syndromes or abnormal airway anatomy in children, although around 20% of difficult intubations are unanticipated. The majority of complications occur when attempting a difficult tracheal intubation. Morbidity and mortality relating to tracheal intubation correlate to the number of attempts at tracheal intubation. Severe hypoxia is estimated to occur in around 9% of children who are difficult to intubate and hypoxic cardiac arrest in nearly 2%, so the key to successful airway management is to focus on maintaining oxygenation and choosing a technique with the best chance of a successful outcome during the first attempt at airway management. This review contains 6 figures, 7 tables, and 41 references.  Keywords: cricothyrotomy, difficult airway, direct laryngoscopy, fiberoptic bronchoscopy, front of neck access, intubation, pediatric, videolaryngoscopy


2021 ◽  
Vol 11 (3) ◽  
Author(s):  
Say Yang Ong ◽  
Vanessa Moll ◽  
Berthold Moser ◽  
Amit Prabhakar ◽  
Elyse M. Cornett ◽  
...  

Implication Statement: Despite the increasing popularity of video laryngoscopes, the supraglottic airway device (SAD) remains a critical airway rescue tool. The SAD provides a conduit for tracheal intubation in failed laryngoscopy. This article aims to help the operator: (1) select an intubating SAD with consistent performance; (2) inform the appropriate SAD-endotracheal tube pairings; and (3) explain various SAD and endotracheal tube maneuvers available to increase chances of successful intubation. Objectives: The first supraglottic airway device (SAD) was introduced more than thirty years ago. Since then, SADs have undergone multiple iterations and improvements. The SAD remains an airway rescue device for ventilation and an intubation conduit on difficult airway algorithms. Data Sources: Several SADs are specifically designed to facilitate tracheal intubation, i.e., “intubating SADs,” while most are “non-intubating SADs.” The two most commonly reported tracheal intubation methods via the SADs are the blind and visualized passage of the endotracheal tube (ETT) preloaded on a fiberoptic scope. Fiberoptic guided tracheal intubation (FOI) via an intubating SAD generally has higher success rates than blind intubations and is thus preferred. However, fiberscopes might not always be readily available, and anesthesiologists should be skilled to successfully intubate blindly through a SAD. Summery: This narrative review describes intubating SAD with consistent performance, appropriate SAD-ETT pairings, and various SAD and ETT maneuvers to increase successful intubation chances.


Resuscitation ◽  
2017 ◽  
Vol 119 ◽  
pp. 1-4 ◽  
Author(s):  
Veer D. Vithalani ◽  
Sabrina Vlk ◽  
Steven Q. Davis ◽  
Neal J. Richmond

2021 ◽  
Vol 9 ◽  
Author(s):  
Teiji Sawa ◽  
Atsushi Kainuma ◽  
Koichi Akiyama ◽  
Mao Kinoshita ◽  
Masayuki Shibasaki

Difficult airway management (DAM) in neonates and infants requires anesthesiologists and critical care clinicians to respond rapidly with appropriate evaluation of specific situations. Therefore, organizing information regarding DAM devices and device-oriented guidance for neonate and infant DAM treatment will help practitioners select the safest and most effective strategy. Based on DAM device information and reported literature, there are three modern options for DAM in neonates and infants that can be selected according to the anatomical difficulty and device-oriented strategy: (1) video laryngoscope (VLS), (2) supraglottic airway device (SAD), and (3) flexible fiberoptic scope (FOS). Some VLSs are equipped with small blades for infants. Advanced SADs have small sizes for infants, and some effectively function as conduits for endotracheal intubation. The smallest FOS has an outer diameter of 2.2 mm and enables intubation with endotracheal tubes with an inner diameter of 3.0 mm. DAM in neonates and infants can be improved by effectively selecting the appropriate device combination and ensuring that available providers have the necessary skills.


Sign in / Sign up

Export Citation Format

Share Document