Clinical evaluation of the v-gel supraglottic airway device in comparison with a classical laryngeal mask and endotracheal intubation in cats during spontaneous and controlled mechanical ventilation

2016 ◽  
Vol 43 (1) ◽  
pp. 55-62 ◽  
Author(s):  
Sarah A Prasse ◽  
Johanna Schrack ◽  
Sandra Wenger ◽  
Martina Mosing
2020 ◽  
Vol 5 (1) ◽  
pp. 149-152
Author(s):  
Sanjay Melville Masih ◽  
Rakesh Kumar Gupta

Background: To facilitate tracheal intubation, intubating laryngeal mask airway(ILMA) was designed specifically. A relatively new supraglottic airway device, air-Q ILA is an alternative to ILMA to facilitate endotracheal intubation. Considering advantages of air-Q over ILMA are that the breathing tube of the device is shorter, wider and due to removable connector, a standard e Parker Flex Tip tracheal tube (product of Parker Medical Company) has a curved, centered, flexible and tapered distal tip that is designed to facilitate easy, rapid and non-traumatic intubation. It has double murphy eyes with an anterior curvature and a posterior opening bevel. It is designed so that the posterior bevel will decrease the incidence of the tube catching at the anterior or the lateral laryngeal structures during tracheal intubation.Subjects and Methods: This is a randomized, single-blind study. Total of 100 patients of either sex aged 18–60 years belonging to American Society of Anaesthesiologists (ASA) physical status I or II scheduled for elective surgery under general anesthesia with endotracheal intubation were included in the study and the patients with respiratory or pharyngeal pathology, mouth opening < 2.5 cm, body mass index ≥35 kg/m2, pregnancy and anticipated difficult airway were excluded from the study. The duration of the study was one year. The ethical clearance was taken from the institutional ethical committee. Written informed consent from all participants was obtained for participation in the study. Results: A total of 100 patients were allocated for the study. The insertion of the airway device was successful in all the patients of group 1. So, 50  patients were analysed for intubation in group 1. Air-Q ILA could not be inserted and resulted in failure in two cases. Hence, 48 patients were analysed statistically for intubation in group 2. The two groups were comparable with respect to age, weight and sex distribution. The mean age of patients in group 1 was 40.00 ± 10.76 years and in group 2 it was 40.56 ± 11.0 years (P = 0.651). There were 30 females and 20 males both in group 1 and group 2 (P = 1.000). The mean weight of patients in group 1 was 60.34 ± 8.06 kg and in group 2 was 60.10 ± 10.05 kg (P = 0.924). Conclusion:The  overall success rate using Parker Flex Tip tube was more with ILMA (99%) as compared to air-Q ILA (78%). It can be further suggested that Parker Flex Tip tube can be used as an alternative to silicone tube with ILMA, but more multicentre studies are required over larger populations to evaluate the utility of Parker Flex Tip tube with air-Q ILA.


2012 ◽  
Vol 116 (6) ◽  
pp. 1217-1226 ◽  
Author(s):  
Satya Krishna Ramachandran ◽  
Michael R. Mathis ◽  
Kevin K. Tremper ◽  
Amy M. Shanks ◽  
Sachin Kheterpal

Background Although the estimated risk of life-threatening adverse respiratory events during supraglottic airway device use is rare, the reported rate of events leading to failure of the airway device is 0.2-8%. Little is known about the risk-adjusted prediction of Laryngeal Mask Airway failure requiring rescue tracheal intubation and its impact on patient outcomes. Methods All adult patients in whom a laryngeal mask airway (LMA Unique™, uLMA™; LMA North America, Inc., San Diego, CA) was used in ambulatory and nonambulatory anesthesia settings were included. The primary outcome was uLMA™ failure, defined as an airway event requiring uLMA™ removal and tracheal intubation. The secondary outcomes were the incidence of difficult mask ventilation and unplanned hospital admissions. Results Of the 15,795 cases included in our study, 170 (1.1%) experienced the primary outcome of uLMA™ failure. More than 60% of patients with uLMA™ failure experienced significant hypoxia, hypercapnia, or airway obstruction, whereas 42% presented with inadequate ventilation related to leak. Four independent risk factors for failed uLMA™ were identified: surgical table rotation, male sex, poor dentition, and increased body mass index. A 3-fold increased incidence of difficult mask ventilation was observed in patients with uLMA™ failure. Among outpatients with uLMA™ failure, 13.7% had unplanned hospital admission, 5.6% of whom needed intensive care for persistent hypoxemia. Conclusions The study supports the use of the uLMA™ as an effective supraglottic airway device with a relatively low failure rate. However, there are clinically relevant consequences of uLMA™ failure, as evidenced by the high rate of acute respiratory events and need for unplanned hospital admissions.


Sign in / Sign up

Export Citation Format

Share Document