scholarly journals Three-dimensional parametric mapping in quantitative micro-CT imaging of post-surgery femoral head-neck samples: preliminary results

Author(s):  
S Giannotti
2020 ◽  
Vol 8 (7_suppl6) ◽  
pp. 2325967120S0039
Author(s):  
Layla Haidar ◽  
Ryan Warth ◽  
Erinn Pemberton Annie Waite ◽  
Alfred Mansour

Objectives: Cam-type femoroacetabular impingement (FAI) is a three-dimensional (3D) deformity that is still difficult to assess using traditional two-dimensional (2D) radiographic views. While measurements of alpha angle and head-neck offset are used to estimate the likelihood of actual impingement, these 2D measurements do not account for z-axis variations in femoral version (FV) and neck-shaft angle (NSA). The purpose of this qualitative proof-of-concept study was to evaluate the potential variation in alpha angle and neck-shaft offset measurements with incremental changes in NSA and FV by simulating traditional radiographic views with software-generated Digitally-Reconstructed Radiographs (DRRs). We hypothesize that incremental changes in hip morphology will produce qualitative changes in alpha angle and neck-shaft offset. Methods: 3D-CT reconstruction images were obtained from one subject with symptomatic cam-type FAI. The 3D reconstruction was cleaned to include only the femoral head, neck and subtrochanteric region along with the ipsilateral hemipelvis. Using 3D medical image processing software (Mimics; Materialise, Inc.; Belgium), the pre-processed 3D model was manipulated in a standardized manner to simulate 5-degree incremental variations in FV and NSA (-15 degrees to +15 degrees for FV; -15 degrees to +10 degrees for NSA). Negative FV reflected external rotation of the femoral head-neck unit, whereas negative NSA reflected abduction of the femoral head-neck unit. Each modified 3D model was then used to generate DRRs corresponding to traditional 2D radiographic views used for assessment of cam-FAI (Anteroposterior [AP], False Profile [FP]), Cross Table Lateral [CTL], Frog Leg Lateral [FLL], 45- and 90-degree Dunn [45D and 90D, respectively]. Alpha angle and head-neck offset were measured on each radiographic view corresponding to each incremental change in FV and NSA. All measurements utilized the perfect circle technique and were made by two independent observers for assessment of inter-observer reliability. Two-way random effects ANOVA was used for statistical assessment of inter-observer reliability and reported as intra-class correlation coefficients (κ). Comparisons between groups were performed using two-tailed paired t-tests assuming unequal variance. P-values less than 0.05 were considered statistically significant. Results: Inter-observer reliability (κ) for head-neck offset and alpha angles were 0.46 (fair) and 0.88 (excellent), respectively. Variations in head-neck offset and alpha angle with incremental variations in FV and NSA are summarized in Figure 1. There were statistically significant changes in mean alpha angles when the NSA was adjusted from Neutral to -5 degrees (p=0.01) and from -5 degrees to -10 degrees (p<0.001). There were no statistically significant differences in alpha angles or head-neck offsets between each incremental change in FV (p<0.05). Alpha angle measurements were significantly more variable than head-neck offset measurements for all variations in FV (p<0.001) and NSA (p=0.02) (Figure 2). Conclusion: Two-dimensional evaluation of three-dimensional Cam morphology (alpha angle and head-neck offset) was found to be significantly affected by alterations in femoral version and head-neck offset. Head-neck offset measurements were significantly less variable than alpha angle measurements across all FVs and NSAs within each radiographic view. Future work should be done to develop standardized procedures for routine 3D radiographic assessment of cam-type FAI. [Figure: see text][Figure: see text]


2019 ◽  
pp. 75-81 ◽  
Author(s):  
Ismail Hakki Baltacioglu ◽  
◽  
Gulbike Demirel ◽  
Mehmet Eray Kolsuz ◽  
Kaan Orhan ◽  
...  

2014 ◽  
Vol 553 ◽  
pp. 287-292
Author(s):  
W. Theodore ◽  
J. Pierrepont ◽  
Q. Li ◽  
B. Miles

The modularity of femoral head and femoral stem provides many benefits to surgeons. However, case-reports have shown failure in large head Metal-on-Metal hip replacement due to trunnionosis. The exact causes of trunnionosis are not yet identified but the additional interface at the modular joint seems to be a contributing factor. In this study, a three dimensional non-linear finite element model was created to analyse the effects of head size and trunnion design on the micromotion at the head-neck interface. Four different metal head sizes and two trunnions designs and materials were used in the model. The femoral heads were assembled onto the trunnions with 7kN axial force and one cycle of gait load was applied to the head after assembly. The study showed that the micromotion was substantially increased in femoral head larger than 36mm. Trunnions material has greater effect on micromotion than trunnion design, particularly with the larger head sizes. The stability at the modular junction is important. Our findings suggest that there is a limit of assembly force to maintain enough stability on the joint; beyond this limit; the maximum micromotion will not be affected.


2011 ◽  
Vol 27 (11) ◽  
pp. 1070-1078 ◽  
Author(s):  
Eitetsu Cho ◽  
Alireza Sadr ◽  
Norimich Inai ◽  
Junji Tagami

2017 ◽  
Vol 122 (1) ◽  
pp. 161-169 ◽  
Author(s):  
Dragoş M. Vasilescu ◽  
André B. Phillion ◽  
Naoya Tanabe ◽  
Daisuke Kinose ◽  
David F. Paige ◽  
...  

Micro-computed tomography (CT) enables three-dimensional (3D) imaging of complex soft tissue structures, but current protocols used to achieve this goal preclude cellular and molecular phenotyping of the tissue. Here we describe a radiolucent cryostage that permits micro-CT imaging of unfixed frozen human lung samples at an isotropic voxel size of (11 µm)3 under conditions where the sample is maintained frozen at −30°C during imaging. The cryostage was tested for thermal stability to maintain samples frozen up to 8 h. This report describes the methods used to choose the materials required for cryostage construction and demonstrates that whole genome mRNA integrity and expression are not compromised by exposure to micro-CT radiation and that the tissue can be used for immunohistochemistry. The new cryostage provides a novel method enabling integration of 3D tissue structure with cellular and molecular analysis to facilitate the identification of molecular determinants of disease. NEW & NOTEWORTHY The described micro-CT cryostage provides a novel way to study the three-dimensional lung structure preserved without the effects of fixatives while enabling subsequent studies of the cellular matrix composition and gene expression. This approach will, for the first time, enable researchers to study structural changes of lung tissues that occur with disease and correlate them with changes in gene or protein signatures.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
David B. Kastner ◽  
Viktor Kharazia ◽  
Rhino Nevers ◽  
Clay Smyth ◽  
Daniela A. Astudillo-Maya ◽  
...  

AbstractAnatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.


2020 ◽  
Author(s):  
David B. Kastner ◽  
Viktor Kharazia ◽  
Rhino Nevers ◽  
Daniela A. Astudillo-Maya ◽  
Greer M. Williams ◽  
...  

AbstractAnatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesions studies require removal of the skull and hazardous chemicals, dehydration or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of brain lesions.


Sign in / Sign up

Export Citation Format

Share Document