A novel experimental procedure is presented which allows simultaneous identification of heat and work transfer parameters for turbocharger compressor models. The method introduces a thermally transient condition and uses temperature measurements to extract the adiabatic efficiency and internal convective heat transfer coefficient simultaneously, thus capturing the aerodynamic and thermal performance. The procedure has been implemented both in simulation and experimentally on a typical turbocharger gas stand facility. Under ideal conditions, the new identification predicted adiabatic efficiency to within 1% point1 and heat transfer coefficient to within 1%. A sensitivity study subsequently showed that the method is particularly sensitive to the assumptions of heat transfer distribution pre- and postcompression. If 20% of the internal area of the compressor housing is exposed to the low pressure intake gas, and this is not correctly assumed in the identification process, errors of 7–15% points were observed for compressor efficiency. This distribution in heat transfer also affected the accuracy of heat transfer coefficient which increased to 20%. Thermocouple sensors affect the transient temperature measurements and in order to maintain efficiency errors below 1%, probes with diameter of less than 1.5 mm should be used. Experimentally, the method was shown to reduce the adiabatic efficiency error at 90 krpm and 110 krpm compared to industry-standard approach from 6% to 3%. However at low speeds, where temperature differences during the identification are small, the method showed much larger errors.

Author(s):  
Richard Burke ◽  
Pablo Olmeda ◽  
José Ramón Serrano

A novel experimental procedure is presented which allows simultaneous identification of heat and work transfer parameters for turbocharger compressor models. The method introduces a thermally transient condition and uses temperature measurements to extract the adiabatic efficiency and internal convective heat transfer coefficient simultaneously, thus capturing the aerodynamic and thermal performance. The procedure has been implemented both in simulation and experimentally on a typical turbocharger gas stand facility. Under ideal conditions, the new identification predicted adiabatic efficiency to within 1%point and heat transfer coefficient to within 1%. A sensitivity study subsequently showed that the method is particularly sensitive to the assumptions of heat transfer distribution pre and post compression. If 20% of the internal area of the compressor housing is exposed to the low pressure intake gas, and this is not correctly assumed in the identification process, errors of 7–15%points were observed for compressor efficiency. This distribution in heat transfer also affected the accuracy of heat transfer coefficient which increased to 20%. Thermocouple sensors affect the transient temperature measurements and in order to maintain efficiency errors below 1%, probes with diameter of less than 1.5mm should be used. Experimentally, the method was shown to reduce the adiabatic efficiency error at 90krpm and 110krpm compared to industry standard approach from 6% to 3%. However at low speeds, where temperature differences during the identification are small, the method showed much larger errors.


Sign in / Sign up

Export Citation Format

Share Document