Upstream Film Cooling on the Contoured Endwall of a Transonic Turbine Vane in an Annular Cascade

2021 ◽  
Vol 143 (6) ◽  
Author(s):  
Daniel A. Salinas ◽  
Izhar Ullah ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
John W. McClintic ◽  
...  

Abstract The effects of mainstream flow velocity, density ratio (DR), and coolant-to-mainstream mass flow ratio (MFR) on a vane endwall in a transonic, annular cascade were investigated. A blow down facility consisting of five vanes was used. The film cooling effectiveness was measured using binary pressure-sensitive paint (BPSP). The mainstream flow was set using isentropic exit Mach numbers of 0.7 and 0.9. The coolant-to-mainstream density ratio varied from 1.0 to 2.0. The coolant-to- mainstream MFR varied from 0.75% to 1.25%. The endwall was cooled by 18 discrete holes located upstream of the vane passage to provide cooling to the upstream half of the endwall. Due to the curvature of the vane endwall, the upstream holes provided uniform coverage entering the endwall passage. The coverage was effective leading to the throat of the passage, where the downstream holes could provide additional protection. Increasing the coolant flowrate increased the effectiveness provided by the film cooling holes. Increasing the density of the coolant increases the effectiveness on the endwall while enhancing the lateral spread of the coolant. Finally, increasing the velocity of the mainstream while holding the MFR constant also yields increased protection on the endwall. Over the range of flow conditions considered in this study, the binary pressure-sensitive paint proved to be a valuable tool for obtaining detailed pressure and film effectiveness distributions.

Author(s):  
Daniel A. Salinas ◽  
Izhar Ullah ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
John W. McClintic ◽  
...  

Abstract The effects of mainstream flow velocity, density ratio (DR), and coolant-to-mainstream mass flow ratio (MFR) were investigated on a vane endwall in a transonic, annular cascade. A blow down facility consisting of five vanes was used. The film cooling effectiveness was measured using binary pressure sensitive paint (BPSP). The mainstream flow was set using isentropic exit Mach numbers of 0.7 and 0.9. The coolant-to-mainstream density ratio varied from 1.0 to 2.0. The coolant to mainstream MFR varied from 0.75% to 1.25%. The endwall was cooled by eighteen discrete holes located upstream of the vane passage to provide cooling to the upstream half of the endwall. Due to the curvature of the vane endwall, the upstream holes provided uniform coverage entering the endwall passage. The coverage was effective leading to the throat of the passage, where the downstream holes could provide additional protection. Increasing the coolant flowrate increased the effectiveness provided by the film cooling holes. Increasing the density of the coolant increases the effectiveness on the endwall while enhancing the lateral spread of the coolant. Finally, increasing the velocity of the mainstream while holding the MFR constant also yields increased protection on the endwall. Over the range of flow conditions considered in this study, the binary pressure sensitive paint proved to be a valuable tool for obtaining detailed pressure and film effectiveness distributions.


Author(s):  
Travis B. Watson ◽  
Kyle R. Vinton ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

Abstract The effect of film cooling hole inlet geometry is experimentally investigated in this study. Detailed film cooling effectiveness distributions are obtained on a flat plate using Pressure Sensitive Paint (PSP). The inlet of a traditional 12°-12°-12°, laidback, fanshaped hole varies from a traditional “round” opening to an oblong, racetrack shaped opening. In this study, a single racetrack inlet with an aspect ratio of 2:1 is compared to the round inlet. For both designs, the holes are inclined at θ = 30° relative to the mainstream. Blowing ratios of 0.5, 1.0, and 1.5 are considered as the coolant–to–mainstream density ratio varies between 1.0 and 4.0. For all cases, the freestream turbulence intensity is maintained at 7.5%. With the introduction of the racetrack shaped inlet, the coolant spreads laterally across the diffuse, laidback fanshaped outlet. The centerline film cooling effectiveness is reduced with the enhanced lateral spread of the coolant. However, the benefit of the shaped inlet is also observed with an increase in the area averaged film cooling effectiveness, compared to the traditional round inlet. Not only does the shaped inlet promote spreading of the coolant, it is also believed the racetrack shape suppresses turbulence within the hole allowing for enhanced film cooling protection near the film cooling holes.


2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.


Author(s):  
Manuel Wilhelm ◽  
Heinz-Peter Schiffer

Rotor tip film cooling is investigated at the Large Scale Turbine Rig, which is a 1.5-stage axial turbine rig operating at low speeds. Using pressure sensitive paint, the film cooling effectiveness η at a squealer-type blade tip with cylindrical pressure-side film cooling holes is obtained. The effect of turbine inlet swirl on η is examined in comparison to an axial inflow baseline case. Coolant-to-mainstream injection ratios are varied between 0.45% and 1.74% for an engine-realistic coolant-to-mainstream density ratio of 1.5. It is shown that inlet swirl causes a reduction in η for low injection ratios by up to 26%, with the trailing edge being especially susceptible to swirl. For injection ratios greater than 0.93%, however, η is increased by up to 11% for swirling inflow, while for axial inflow a further increase in coolant injection does not transfer into a gain in η .


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke-wheel wake generator) on the modeled rotor blade is studied using the pressure sensitive paint (PSP) mass-transfer analogy method. Emphasis of the current study is on the midspan region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film-cooling holes. The blade also has radial shower-head leading edge film-cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side and 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film-cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Nian Wang ◽  
Mingjie Zhang ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

This study investigates the effects of blowing ratio, density ratio, and spanwise pitch on the flat plate film cooling from two rows of compound angled cylindrical holes. Two arrangements of two-row compound angled cylindrical holes are tested: (a) the first row and the second row are oriented in staggered and same compound angled direction (β = +45 deg for the first row and +45 deg for the second row); (b) the first row and the second row are oriented in inline and opposite direction (β = +45 deg for the first row and −45 deg for the second row). The cooling hole is 4 mm in diameter with an inclined angle of 30 deg. The streamwise row-to-row spacing is fixed at 3d, and the spanwise hole-to-hole (p) is varying from 4d, 6d to 8d for both designs. The film cooling effectiveness measurements were performed in a low-speed wind tunnel in which the turbulence intensity is kept at 6%. There are 36 cases for each design including four blowing ratios (M = 0.5, 1.0, 1.5, and 2.0), three density ratios (DR = 1.0, 1.5, and 2.0), and three hole-to-hole spacing (p/d = 4, 6, and 8). The detailed film cooling effectiveness distributions were obtained by using the steady-state pressure-sensitive paint (PSP) technique. The spanwise-averaged cooling effectiveness are compared over the range of flow parameters. Some interesting observations are discovered including blowing ratio effect strongly depending on geometric design; staggered arrangement of the hole with same orientation does not yield better effectiveness at higher blowing ratio. Currently, film cooling effectiveness correlation of two-row compound angled cylindrical holes is not available, so this study developed the correlations for the inline arrangement of holes with opposing angles and the staggered arrangement of holes with same angles. The results and correlations are expected to provide useful information for the two-row flat plate film cooling analysis.


Author(s):  
Sehjin Park ◽  
Eui Yeop Jung ◽  
Seon Ho Kim ◽  
Ho-Seong Sohn ◽  
Hyung Hee Cho

Film cooling is a cooling method used to protect the hot components of a gas turbine from high temperature conditions. For this purpose, high and uniform film cooling effectiveness is required to protect the vanes/blades from excessive thermal stress. Backward injection is proposed as one of the methods for the improvement of film cooling effectiveness. In this study, experiments were performed to investigate the effect of backward injection on film cooling effectiveness, using pressure sensitive paint (PSP) method. Four experimental configurations were composed of forward and backward injection cylindrical holes. The cylindrical holes were aligned in two staggered rows with pitch (p) of 6d and row spacing (s) of 3d. The injection angles (α) of the cylindrical holes were 35° and 145° for forward and backward injection, respectively. The blowing ratios (M) ranged from 0.5 to 2.0 and the density ratio (DR) was about 1. The results indicate that backward injection enhanced not only film cooling effectiveness but also the lateral cooling uniformity. At a high blowing ratio, all configurations demonstrated higher film cooling effectiveness with backward injection than with only forward injection; thus, the dispersion of the backward injection jets enhanced the lateral coverage over wide areas. Configuration, in particular, arranged with forward injection in the first row and backward injection in the second row, obtained the highest film cooling effectiveness among the four cases studied, due to the dispersion of the backward injection jets and the coolant supply from the forward injection jets at a high blowing ratio.


2008 ◽  
Vol 131 (1) ◽  
Author(s):  
A. Suryanarayanan ◽  
S. P. Mhetras ◽  
M. T. Schobeiri ◽  
J. C. Han

Film cooling effectiveness measurements under rotation were performed on the rotor blade platform using a pressure sensitive paint (PSP) technique. The present study examines, in particular, the film cooling effectiveness due to purging of coolant from the wheel-space cavity through the circumferential clearance gap provided between the stationary and rotating components of the turbine. The experimental investigation is carried out in a new three-stage turbine facility, recently designed and taken into operation at the Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. This new turbine rotor has been used to facilitate coolant injection through this stator-rotor gap upstream of the first stage rotor blade. The gap was inclined at 25deg to mainstream flow to allow the injected coolant to form a film along the passage platform. The effects of turbine rotating conditions on the blade platform film cooling effectiveness were investigated at three speeds of 2550rpm, 2000rpm, and 1500rpm with corresponding incidence angles of 23.2deg, 43.4deg, and 54.8deg, respectively. Four different coolant-to-mainstream mass flow ratios varying from 0.5% to 2.0% were tested at each rotational speed. Aerodynamic measurements were performed at the first stage stator exit using a radially traversed five-hole probe to quantify the mainstream flow at this station. Results indicate that film cooling effectiveness increases with an increase in the coolant-to-mainstream mass flow ratios for all turbine speeds. Higher turbine rotation speeds show more local film cooling effectiveness spread on the platform with increasing magnitudes.


Author(s):  
A. Suryanarayanan ◽  
S. P. Mhetras ◽  
M. T. Schobeiri ◽  
J. C. Han

Film cooling effectiveness measurements under rotation were performed on the rotor blade platform using a pressure sensitive paint (PSP) technique. The present study examines, in particular, the film cooling effectiveness due to purging of coolant from the wheel-space cavity through the circumferential clearance gap provided between the stationary and rotating components of the turbine. The experimental investigation is carried out in a new three-stage turbine facility, recently designed and taken into operation at the Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. This new turbine rotor has been used to facilitate coolant injection through this stator-rotor gap upstream of the 1st stage rotor blade. The gap was inclined at 25° to mainstream flow to allow the injected coolant to form a film along the passage platform. The effects of turbine rotating conditions on the blade platform film cooling effectiveness were investigated at three speeds of 2550 rpm, 2000 rpm and 1500 rpm with corresponding incidence angles of 23.2°, 43.4° and 54.8° respectively. Four different coolant-to-mainstream mass flow ratios varying from 0.5% to 2.0% were tested at each rotational speed. Aerodynamic measurements were performed at the 1st stage stator exit using a radially traversed five-hole probe to quantify the mainstream flow at this station. Results indicate that film cooling effectiveness increases with an increase in the coolant-to-mainstream mass flow ratios for all turbine speeds. Higher turbine rotation speeds show more local film cooling effectiveness spread on the platform with increasing magnitudes.


2013 ◽  
Vol 136 (5) ◽  
Author(s):  
Shiou-Jiuan Li ◽  
Shang-Feng Yang ◽  
Je-Chin Han

The density ratio effect on leading edge showerhead film cooling has been studied experimentally using the pressure sensitive paint (PSP) mass transfer analogy method. The leading edge model is a blunt body with a semicylinder and an after body. There are two designs: seven-row and three-row of film cooling holes for simulating a vane and blade, respectively. The film holes are located at 0 (stagnation row), ±15, ±30, and ±45 deg for the seven-row design, and at 0 and ±30 for the three-row design. Four film hole configurations are used for both test designs: radial angle cylindrical holes, compound angle cylindrical holes, radial angle shaped holes, and compound angle shaped holes. The coolant to mainstream density ratio varies from DR = 1.0, 1.5, to 2.0 while the blowing ratio varies from M = 0.5 to 2.1. Experiments were conducted in a low speed wind tunnel with Reynolds number 100,900 based on mainstream velocity and diameter of the cylinder. The mainstream turbulence intensity near the leading edge model is about 7%. The results show the shaped holes have an overall higher film cooling effectiveness than the cylindrical holes, and the radial angle holes are better than the compound angle holes, particularly at a higher blowing ratio. A larger density ratio makes more coolant attach to the surface and increases film protection for all cases. Radial angle shaped holes provide the best film cooling at a higher density ratio and blowing ratio for both designs.


Sign in / Sign up

Export Citation Format

Share Document