Influence of Hole Inlet Geometry on the Film Cooling Effectiveness From Shaped Film Cooling Holes

Author(s):  
Travis B. Watson ◽  
Kyle R. Vinton ◽  
Lesley M. Wright ◽  
Daniel C. Crites ◽  
Mark C. Morris ◽  
...  

Abstract The effect of film cooling hole inlet geometry is experimentally investigated in this study. Detailed film cooling effectiveness distributions are obtained on a flat plate using Pressure Sensitive Paint (PSP). The inlet of a traditional 12°-12°-12°, laidback, fanshaped hole varies from a traditional “round” opening to an oblong, racetrack shaped opening. In this study, a single racetrack inlet with an aspect ratio of 2:1 is compared to the round inlet. For both designs, the holes are inclined at θ = 30° relative to the mainstream. Blowing ratios of 0.5, 1.0, and 1.5 are considered as the coolant–to–mainstream density ratio varies between 1.0 and 4.0. For all cases, the freestream turbulence intensity is maintained at 7.5%. With the introduction of the racetrack shaped inlet, the coolant spreads laterally across the diffuse, laidback fanshaped outlet. The centerline film cooling effectiveness is reduced with the enhanced lateral spread of the coolant. However, the benefit of the shaped inlet is also observed with an increase in the area averaged film cooling effectiveness, compared to the traditional round inlet. Not only does the shaped inlet promote spreading of the coolant, it is also believed the racetrack shape suppresses turbulence within the hole allowing for enhanced film cooling protection near the film cooling holes.

2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke-wheel wake generator) on the modeled rotor blade is studied using the pressure sensitive paint (PSP) mass-transfer analogy method. Emphasis of the current study is on the midspan region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film-cooling holes. The blade also has radial shower-head leading edge film-cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side and 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film-cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


Author(s):  
Izhar Ullah ◽  
Sulaiman Alsaleem ◽  
Lesley Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade's leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint measurement technique. In addition, detailed film cooling effectiveness and over-tip flow leakage is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip.


Author(s):  
Daniel A. Salinas ◽  
Izhar Ullah ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
John W. McClintic ◽  
...  

Abstract The effects of mainstream flow velocity, density ratio (DR), and coolant-to-mainstream mass flow ratio (MFR) were investigated on a vane endwall in a transonic, annular cascade. A blow down facility consisting of five vanes was used. The film cooling effectiveness was measured using binary pressure sensitive paint (BPSP). The mainstream flow was set using isentropic exit Mach numbers of 0.7 and 0.9. The coolant-to-mainstream density ratio varied from 1.0 to 2.0. The coolant to mainstream MFR varied from 0.75% to 1.25%. The endwall was cooled by eighteen discrete holes located upstream of the vane passage to provide cooling to the upstream half of the endwall. Due to the curvature of the vane endwall, the upstream holes provided uniform coverage entering the endwall passage. The coverage was effective leading to the throat of the passage, where the downstream holes could provide additional protection. Increasing the coolant flowrate increased the effectiveness provided by the film cooling holes. Increasing the density of the coolant increases the effectiveness on the endwall while enhancing the lateral spread of the coolant. Finally, increasing the velocity of the mainstream while holding the MFR constant also yields increased protection on the endwall. Over the range of flow conditions considered in this study, the binary pressure sensitive paint proved to be a valuable tool for obtaining detailed pressure and film effectiveness distributions.


2005 ◽  
Vol 127 (5) ◽  
pp. 521-530 ◽  
Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film-cooling holes, and the tip-gap clearance on the film-cooling effectiveness were studied and compared to those for a plane (flat) tip. The film-cooling effectiveness distributions were measured on the blade tip using the pressure-sensitive paint technique. Air and nitrogen gas were used as the film-cooling gases, and the oxygen concentration distribution for each case was measured. The film-cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film-cooling holes were located (a) along the camber line on the tip or (b) along the tip of the pressure side. The average blowing ratio of the cooling gas was 0.5, 1.0, and 2.0. Tests were conducted with a stationary, five-bladed linear cascade in a blow-down facility. The free-stream Reynolds number, based on the axial chord length and the exit velocity, was 1,138,000, and the inlet and the exit Mach numbers were 0.25 and 0.6, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip-gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film-cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness, with film-cooling effectiveness increasing with increasing blowing ratio.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Marc Fraas ◽  
Tobias Glasenapp ◽  
Achmed Schulz ◽  
Hans-Jörg Bauer

Internal coolant passages of gas turbine vanes and blades have various orientations relative to the external hot gas flow. As a consequence, the inflow of film cooling holes varies as well. To further identify the influencing parameters of film cooling under varying inflow conditions, the present paper provides detailed experimental data. The generic study is performed in a novel test rig, which enables compliance with all relevant similarity parameters including density ratio. Film cooling effectiveness as well as heat transfer of a 10–10–10 deg laidback fan-shaped cooling hole is discussed. Data are processed and presented over 50 hole diameters downstream of the cooling hole exit. First, the parallel coolant flow setup is discussed. Subsequently, it is compared to a perpendicular coolant flow setup at a moderate coolant channel Reynolds number. For the perpendicular coolant flow, asymmetric flow separation in the diffuser occurs and leads to a reduction of film cooling effectiveness. For a higher coolant channel Reynolds number and perpendicular coolant flow, asymmetry increases and cooling effectiveness is further decreased. An increase in blowing ratio does not lead to a significant increase in cooling effectiveness. For all cases investigated, heat transfer augmentation due to film cooling is observed. Heat transfer is highest in the near-hole region and decreases further downstream. Results prove that coolant flow orientation has a severe impact on both parameters.


Author(s):  
Manuel Wilhelm ◽  
Heinz-Peter Schiffer

Rotor tip film cooling is investigated at the Large Scale Turbine Rig, which is a 1.5-stage axial turbine rig operating at low speeds. Using pressure sensitive paint, the film cooling effectiveness η at a squealer-type blade tip with cylindrical pressure-side film cooling holes is obtained. The effect of turbine inlet swirl on η is examined in comparison to an axial inflow baseline case. Coolant-to-mainstream injection ratios are varied between 0.45% and 1.74% for an engine-realistic coolant-to-mainstream density ratio of 1.5. It is shown that inlet swirl causes a reduction in η for low injection ratios by up to 26%, with the trailing edge being especially susceptible to swirl. For injection ratios greater than 0.93%, however, η is increased by up to 11% for swirling inflow, while for axial inflow a further increase in coolant injection does not transfer into a gain in η .


Author(s):  
K. Vighneswara Rao ◽  
Jong S. Liu ◽  
Daniel C. Crites ◽  
Luis A. Tapia ◽  
Malak F. Malak ◽  
...  

In this study, cylindrical and fan shaped film cooling holes are evaluated on the blade surface numerically, using the Computational Fluid Dynamics (CFD) tool ANSYS-CFX, with the objective of improving cooling effectiveness by understanding the flow pattern at the cooling hole exit. The coolant flow rates are adjusted for blowing ratios of 0.5, 1.0 & 1.5 (momentum flux ratios of 0.125, 0.5 & 1.125 respectively). The density ratio is maintained at 2.0. New shaped holes viz. straight, concave and convex trench holes are introduced and are evaluated under similar operating conditions. Results are presented in terms of surface temperatures and adiabatic effectiveness at three different blowing ratios for the different film cooling hole shapes analyzed. Comparison is made with reference to the fan shaped film cooling hole to bring out relative merits of different shapes. The new trench holes improved the film cooling effectiveness by allowing more residence time for coolant to spread laterally while directing smoothly onto the airfoil surface. While convex trench improved the centre-line effectiveness, straight trench improved the laterally-averaged and overall effectiveness at all blowing ratios. Concave trench improved the effectiveness at blowing ratios 0.5 and 1.0.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Nian Wang ◽  
Mingjie Zhang ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

This study investigates the effects of blowing ratio, density ratio, and spanwise pitch on the flat plate film cooling from two rows of compound angled cylindrical holes. Two arrangements of two-row compound angled cylindrical holes are tested: (a) the first row and the second row are oriented in staggered and same compound angled direction (β = +45 deg for the first row and +45 deg for the second row); (b) the first row and the second row are oriented in inline and opposite direction (β = +45 deg for the first row and −45 deg for the second row). The cooling hole is 4 mm in diameter with an inclined angle of 30 deg. The streamwise row-to-row spacing is fixed at 3d, and the spanwise hole-to-hole (p) is varying from 4d, 6d to 8d for both designs. The film cooling effectiveness measurements were performed in a low-speed wind tunnel in which the turbulence intensity is kept at 6%. There are 36 cases for each design including four blowing ratios (M = 0.5, 1.0, 1.5, and 2.0), three density ratios (DR = 1.0, 1.5, and 2.0), and three hole-to-hole spacing (p/d = 4, 6, and 8). The detailed film cooling effectiveness distributions were obtained by using the steady-state pressure-sensitive paint (PSP) technique. The spanwise-averaged cooling effectiveness are compared over the range of flow parameters. Some interesting observations are discovered including blowing ratio effect strongly depending on geometric design; staggered arrangement of the hole with same orientation does not yield better effectiveness at higher blowing ratio. Currently, film cooling effectiveness correlation of two-row compound angled cylindrical holes is not available, so this study developed the correlations for the inline arrangement of holes with opposing angles and the staggered arrangement of holes with same angles. The results and correlations are expected to provide useful information for the two-row flat plate film cooling analysis.


Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film cooling holes, and the tip gap clearance on the film cooling effectiveness were studied and compared to plane tip. The film cooling effectiveness distributions were measured on the blade tip using Pressure Sensitive Paint technique. Air and nitrogen gas were used as the film cooling gases and the oxygen concentration distribution for each case was measured. The film cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film cooling holes were located (a) along the camber line on the tip or (b) along the span of the pressure side. The average blowing ratio of the cooling gas was controlled to be 0.5, 1.0, and 2.0. Tests were conducted in a five-bladed linear cascade with a blow down facility. The free stream Reynolds number, based on the axial chord length and the exit velocity, was 1,100,000 and the inlet and the exit Mach number were 0.25 and 0.59, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness.


Sign in / Sign up

Export Citation Format

Share Document