A Computationally Efficient Lower Limb Finite Element Musculoskeletal Framework Directly Driven Solely by Inertial Measurement Unit Sensors

Author(s):  
Sentong Wang ◽  
Kazunori Hase ◽  
Susumu Ota

Abstract Finite element musculoskeletal (FEMS) approaches using concurrent musculoskeletal and finite element models driven by motion data such as marker-based motion trajectory can provide insight into the interactions between the knee joint secondary kinematics, contact mechanics, and muscle forces in subject-specific biomechanical investigations. However, these data-driven FEMS systems have two major disadvantages that make them challenging to apply in clinical environments: they are computationally expensive and they require expensive and inconvenient equipment for data acquisition. In this study, we developed an FEMS model of the lower limb driven solely by inertial measurement unit sensors that includes the tissue geometries of the entire knee joint and combines muscle modeling and elastic foundation theory-based contact analysis of knee into a single framework. The model requires only the angular velocities and accelerations measured by the sensors as input, and the target outputs (knee contact mechanics, secondary kinematics, and muscle forces) are predicted from the convergence results of iterative calculations of muscle force optimization and knee contact mechanics. To evaluate its accuracy, the model was compared with in vivo experimental data during gait. The maximum contact pressure (12.6 MPa) in the rigid body contact analysis occurred on the medial side of the cartilage at the maximum loading response. The proposed computationally efficient framework drastically reduced the computational time (97.5% reduction) in comparison with the conventional deformable finite element analysis. The developed framework combines measurement convenience and computational efficiency and shows promise for clinical applications.

Biomechanics ◽  
2021 ◽  
Vol 1 (3) ◽  
pp. 293-306
Author(s):  
Sentong Wang ◽  
Kazunori Hase ◽  
Susumu Ota

Finite element musculoskeletal (FEMS) approaches using concurrent musculoskeletal and finite element models driven by motion data such as marker-based motion trajectory can provide insight into the interactions between the knee joint secondary kinematics, contact mechanics, and muscle forces in subject-specific biomechanical investigations. However, these data-driven FEMS systems have a major disadvantage that makes them challenging to apply in clinical environments, i.e., they require expensive and inconvenient equipment for data acquisition. In this study, we developed an FEMS model of the lower limb driven solely by inertial measurement unit sensors that include the tissue geometries of the entire knee joint, and that combine modeling of 16 muscles into a single framework. The model requires only the angular velocities and accelerations measured by the sensors as input. The target outputs (knee contact mechanics, secondary kinematics, and muscle forces) are predicted from the convergence results of iterative calculations of muscle force optimization and knee contact mechanics. To evaluate its accuracy, the model was compared with in vivo experimental data during gait. The maximum contact pressure (11.3 MPa) occurred on the medial side of the cartilage at the maximum loading response. The developed framework combines measurement convenience and accurate modeling, and shows promise for clinical applications aimed at understanding subject-specific biomechanics.


2016 ◽  
Vol 16 (6) ◽  
pp. 1557-1564 ◽  
Author(s):  
Vincent Bonnet ◽  
Vladimir Joukov ◽  
Dana Kulic ◽  
Philippe Fraisse ◽  
Nacim Ramdani ◽  
...  

2019 ◽  
Vol 6 ◽  
pp. 205566831986854 ◽  
Author(s):  
Rob Argent ◽  
Sean Drummond ◽  
Alexandria Remus ◽  
Martin O’Reilly ◽  
Brian Caulfield

Introduction Joint angle measurement is an important objective marker in rehabilitation. Inertial measurement units may provide an accurate and reliable method of joint angle assessment. The objective of this study was to assess whether a single sensor with the application of machine learning algorithms could accurately measure hip and knee joint angle, and investigate the effect of inertial measurement unit orientation algorithms and person-specific variables on accuracy. Methods Fourteen healthy participants completed eight rehabilitation exercises with kinematic data captured by a 3D motion capture system, used as the reference standard, and a wearable inertial measurement unit. Joint angle was calculated from the single inertial measurement unit using four machine learning models, and was compared to the reference standard to evaluate accuracy. Results Average root-mean-squared error for the best performing algorithms across all exercises was 4.81° (SD = 1.89). The use of an inertial measurement unit orientation algorithm as a pre-processing step improved accuracy; however, the addition of person-specific variables increased error with average RMSE 4.99° (SD = 1.83°). Conclusions Hip and knee joint angle can be measured with a good degree of accuracy from a single inertial measurement unit using machine learning. This offers the ability to monitor and record dynamic joint angle with a single sensor outside of the clinic.


2016 ◽  
Vol 2016.51 (0) ◽  
pp. 195-196
Author(s):  
Akira KOMATSU ◽  
Takehiro IWAMI ◽  
Kimio SAITO ◽  
Kazutoshi HATAKEYAMA ◽  
Manabu AKAGAWA ◽  
...  

2016 ◽  
Vol 2016.51 (0) ◽  
pp. 197-198
Author(s):  
kohei TAKEDA ◽  
Taisei HONDA ◽  
Takehiro IWAMI ◽  
Ryota KIMURA ◽  
Toshiki MATSUNAGA ◽  
...  

Author(s):  
Bram J.C. Bastiaansen ◽  
Erik Wilmes ◽  
Michel S. Brink ◽  
Cornelis J. de Ruiter ◽  
Geert J.P. Savelsbergh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document