Two-Phase Pressure Drop and Boiling Heat Transfer in a Single Horizontal Microchannel

Author(s):  
Cheol Huh ◽  
Moo Hwan Kim

With a single microchannel and a series of microheaters made with MEMS technique, two-phase pressure drop and local flow boiling heat transfer were investigated using deionized water in a single horizontal rectangular microchannel. The test microchannel has a hydraulic diameter of 100 μm and length of 40 mm. A real time observation of the flow patterns with simultaneous measurement are made possible. Tests are performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes of from 100 to 600 kW/m2. The experimental local flow boiling heat transfer coefficients and two-phase frictional pressure gradient are evaluated and the effects of heat flux, mass flux, and vapor qualities on flow boiling are studied. Both the evaluated experimental data are compared with existing correlations. The experimental heat transfer coefficients are nearly independent on mass flux and the vapor quality. Most of all correlations do not provide reliable heat transfer coefficients predictions with vapor quality and prediction accuracy. As for two-phase pressure drop, the measured pressure drop increases with the mass flux and heat flux. Most of all existing correlations of two-phase frictional pressure gradient do not predict the experimental data except some limited conditions.

2009 ◽  
Vol 131 (9) ◽  
Author(s):  
Chang Yong Park ◽  
Pega Hrnjak

Abstract C O 2 flow boiling heat transfer coefficients and pressure drop in a 3.5mm horizontal smooth tube are presented. Also, flow patterns were visualized and studied at adiabatic conditions in a 3mm glass tube located immediately after a heat transfer section. Heat was applied by a secondary fluid through two brass half cylinders to the test section tubes. This research was performed at evaporation temperatures of −15°C and −30°C, mass fluxes of 200kg∕m2s and 400kg∕m2s, and heat flux from 5kW∕m2 to 15kW∕m2 for vapor qualities ranging from 0.1 to 0.8. The CO2 heat transfer coefficients indicated the nucleate boiling dominant heat transfer characteristics such as the strong dependence on heat fluxes at a mass flux of 200kg∕m2s. However, enhanced convective boiling contribution was observed at 400kg∕m2s. Surface conditions for two different tubes were investigated with a profilometer, atomic force microscope, and scanning electron microscope images, and their possible effects on heat transfer are discussed. Pressure drop, measured at adiabatic conditions, increased with the increase of mass flux and quality, and with the decrease of evaporation temperature. The measured heat transfer coefficients and pressure drop were compared with general correlations. Some of these correlations showed relatively good agreements with measured values. Visualized flow patterns were compared with two flow pattern maps and the comparison showed that the flow pattern maps need improvement in the transition regions from intermittent to annular flow.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4617
Author(s):  
Sanghyun Nam ◽  
Dae Yeon Kim ◽  
Youngwoo Kim ◽  
Kyung Chun Kim

Heat transfer under flow boiling is better in a rectangular channel filled with open-cell metal foam than in an empty channel, but the high pressure drop is a drawback of the empty channel method. In this study, various types of metal foam insert configurations were tested to reduce the pressure drop while maintaining high heat transfer. Specifically, we measured the boiling heat transfer and pressure drop of a two-phase vertical upward flow of R245fa inside a channel. To measure the pressure and temperature differences of the metal foam, differential pressure transducers and T-type thermocouples were used at both ends of the test section. While the saturation pressure was kept constant at 5.9 bar, the steam quality at the inlet of the test section was changed from 0.05 to 0.99. The channel height, moreover, was 3 mm, and the mass flux ranged from 133 to 300 kg/m2s. The two-phase flow characteristics were observed through a high-speed visualization experiment. Heat transfer tended to increase with the mean vapor quality, and, as expected, the fully filled metal foam channel offered the highest thermal performance. The streamwise insert pattern model had the lowest heat transfer at a low mass flux. However, at a higher mass flux, the three different insert models presented almost the same heat transfer coefficients. We found that the streamwise pattern model had a very low pressure drop compared to that of the spanwise pattern models. The goodness factors of the flow area and the core volume of the streamwise patterned model were higher than those of the full-filled metal foam channel.


Author(s):  
Mehmed Rafet Özdemir ◽  
Alihan Kaya ◽  
Ali Koşar

In this article, an experimental study on boiling heat transfer and fluid flow in microtubes at high mass fluxes is presented. De-ionized water flow was investigated over a broad range of mass flux (1000 kg/m2s–7500 kg/m2s) in microtubes with inner diameters of  ∼ 250 μm and ∼685 μm. The reason for using two different capillary diameters was to investigate the size effect on flow boiling. De-ionized water was used as working fluid, and the test section was heated by Joule heating. Heat transfer coefficients and qualities were deduced from local temperature measurements. It was found that high heat removal rates could be achieved at high flow rates under subcooled boiling conditions. It was also observed that heat transfer coefficients increased with mass flux, whereas they decreased with local quality and heat flux. Moreover, experimental heat flux data were compared with partial boiling correlations and fully developed boiling correlations. It was observed that at low wall superheat values, there was only a small inconsistency between the experimental data and the conventional partial boiling prediction method of Bergles, while the subcooled and low quality fully developed boiling heat transfer correlation of Kandlikar could fairly predict experimental results at high wall superheat values.


Author(s):  
Emily A. Pike-Wilson ◽  
Mohamed M. Mahmoud ◽  
Tassos G. Karayiannis

New refrigerants are required for cooling systems due to the fact that refrigerants like R134a are about to be phased out. This paper presents a comparison between the flow boiling heat transfer and pressure drop results of refrigerants R245fa and R134a. The experiments with R245fa were conducted in a vertical cold drawn stainless steel tube with an inner diameter of 1.1 mm and heated length of 150 mm. Experimental conditions include: mass flux range 100–400 kg/m2s, heat flux range 10–60 kW/m2, pressures of 8 and 10 bar and 1.9 and 2.5 bar for R134a and R245fa corresponding to saturated temperatures 31 °C and 39 °C and exit vapour quality range 0–0.95. The data for R134a were obtained earlier using the same experimental facility at the same experimental conditions and with the same test tube. The results demonstrated that refrigerant properties have a significant effect on heat transfer and pressure drop. The pressure drop of R245fa is higher by up to 300% compared to that of R134a at similar conditions. In addition, the effect of mass flux and heat flux on the local flow boiling heat transfer coefficient was different. Heat transfer coefficients of R245fa showed a greater dependence on vapour quality. The agreement with past heat transfer correlations is better with R134a than with R245fa.


2017 ◽  
Vol 75 ◽  
pp. 1-13 ◽  
Author(s):  
Zahid H. Ayub ◽  
Adnan H. Ayub ◽  
Gherhardt Ribatski ◽  
Tiago Augusto Moreira ◽  
Tariq S. Khan

2014 ◽  
Vol 348 ◽  
pp. 20-26
Author(s):  
I. Pranoto ◽  
C. Yang ◽  
L.X. Zheng ◽  
K.C. Leong ◽  
P.K. Chan

This paper presents an experimental study of flow boiling heat transfer from carbon nanotube (CNT) structures in a two-phase cooling facility. Multi-walled CNT (MWCNT) structures of dimensions 80 mm × 60 mm were applied to a horizontal flow boiling channel. Two CNT structures with different properties viz. NC-3100 and MERCSD were tested with a dielectric liquid FC-72. The height of the CNT structures was fixed at 37.5 μm and tests were conducted at coolant mass fluxes of 35, 50, and 65 kg/m2·s under saturated flow boiling conditions. The experimental results show that the CNT structures enhance the boiling heat transfer coefficients by up to 1.6 times compared to the smooth aluminum surface. The results also show that the CNT structures increase significantly the Critical Heat Flux (CHF) of the smooth aluminum surface from 66.7 W/cm2 to 100 W/cm2.


Author(s):  
Hao Wang ◽  
Xiande Fang

As an excellent cryogenic cooling medium, Nitrogen (N2) has been used in a variety of engineering fields, where the determination of N2 two-phase flow boiling heat transfer is required. There were some studies evaluating the correlations of flow boiling heat transfer coefficient for N2. However, either the number of correlations covered or the number of data used was limited. This work presents a comparative review of existing correlations of flow boiling heat transfer coefficients for N2 applications. A database of N2 flow boiling heat transfer containing 1043 experimental data points is compiled to evaluate 45 correlations of two-phase flow boiling heat transfer. The experimental parameters cover the ranges of mass flux from 28.0 to 1684.8 kg/m2s, heat flux from 0.2 to 135.6 kW/m2, vapor quality from 0.002 to 0.994, saturation pressure from 0.1 to 3.16 MPa, and channel inner diameter from 0.351 to 14 mm. The results show that the best correlation has a mean absolute deviation of 31.8% against the whole database, suggesting that more efforts should be made to study N2 flow boiling heat transfer to develop a more accurate correlation.