Sinogram + image domain neural network approach for metal artifact reduction in low-dose cone-beam computed tomography

2021 ◽  
Vol 8 (05) ◽  
Author(s):  
Michael D. Ketcha ◽  
Michael Marrama ◽  
Andre Souza ◽  
Ali Uneri ◽  
Pengwei Wu ◽  
...  
2021 ◽  
Vol 24 ◽  
pp. 100573
Author(s):  
Goli Khaleghi ◽  
Mohammad Hosntalab ◽  
Mahdi Sadeghi ◽  
Reza Reiazi ◽  
Seied Rabi Mahdavi

2018 ◽  
Vol 24 (3) ◽  
pp. 303-308 ◽  
Author(s):  
Yukiko Enomoto ◽  
Keita Yamauchi ◽  
Takahiko Asano ◽  
Katharina Otani ◽  
Toru Iwama

Background and purpose C-arm cone-beam computed tomography (CBCT) has the drawback that image quality is degraded by artifacts caused by implanted metal objects. We evaluated whether metal artifact reduction (MAR) prototype software can improve the subjective image quality of CBCT images of patients with intracranial aneurysms treated with coils or clips. Materials and methods Forty-four patients with intracranial aneurysms implanted with coils (40 patients) or clips (four patients) underwent one CBCT scan from which uncorrected and MAR-corrected CBCT image datasets were reconstructed. Three blinded readers evaluated the image quality of the image sets using a four-point scale (1: Excellent, 2: Good, 3: Poor, 4: Bad). The median scores of the three readers of uncorrected and MAR-corrected images were compared with the paired Wilcoxon signed-rank and inter-reader agreement of change scores was assessed by weighted kappa statistics. The readers also recorded new clinical findings, such as intracranial hemorrhage, air, or surrounding anatomical structures on MAR-corrected images. Results The image quality of MAR-corrected CBCT images was significantly improved compared with the uncorrected CBCT image ( p < 0.001). Additional clinical findings were seen on CBCT images of 70.4% of patients after MAR correction. Conclusion MAR software improved image quality of CBCT images degraded by metal artifacts.


2020 ◽  
Author(s):  
Fatemeh Salemi ◽  
Mohamad Reza Jamalpour ◽  
Amir Eskandarloo ◽  
Leili Tapak ◽  
Narges Rahimi

UNSTRUCTURED This study aimed to assess the efficacy of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) systems for detection of peri-implant fenestration and dehiscence. Thirty-six titanium implants were placed in bone blocks of bovine ribs. Fenestration and dehiscence were created in the buccal bone around implants using a round bur. The bone blocks were then mounted in a wax rim to simulate the mandible. CBCT images were obtained using Cranex 3D and ProMax 3D CBCT systems with and without MAR algorithm before and after creation of defects. Two experienced radiologists observed the images twice with a 2-week interval. Data were analyzed using SPSS software version 22.The Kappa coefficient of agreement, the area under the receiver operating characteristic (ROC) curve, sensitivity, specificity, accuracy of different imaging modalities were calculated and analyzed. According to the kappa statistics, the intra- and inter-observer agreements were higher for images without the MAR algorithm compared with those with the MAR algorithm. In both CBCT systems, use of MAR algorithm decreased the area under the ROC curve and subsequently the diagnostic accuracy for detection of fenestration and dehiscence. The sensitivity, specificity and accuracy of both CBCT systems were higher in absence of the MAR algorithm. The specificity of ProMax 3D for detection of fenestration was equal with/without the MAR algorithm. Although CBCT is suitable for detection of peri-implant defects, application of the MAR algorithm does not enhance the detection of peri-implant fenestration and dehiscence.


Sign in / Sign up

Export Citation Format

Share Document