Dual-channel fiber-probe for simultaneous imaging of swept source optical coherence tomography and fluorescence spectroscopy

2013 ◽  
Author(s):  
Eun Jung Min ◽  
Jae Hwi Lee ◽  
Jun Geun Shin ◽  
Seong-Min Kwon ◽  
Hyun You ◽  
...  
2010 ◽  
Author(s):  
Seon Young Ryu ◽  
Myeong Jin Ju ◽  
Kwan Seob Park ◽  
Joo Beom Eom ◽  
Byeong Ha Lee

2015 ◽  
Vol 122 (3) ◽  
pp. 585-594 ◽  
Author(s):  
Wen-Chuan Kuo ◽  
Meng-Chun Kao ◽  
Kuang-Yi Chang ◽  
Wei-Nung Teng ◽  
Mei-Yung Tsou ◽  
...  

Abstract Background: Epidural needle insertion is traditionally a blind technique whose success depends on the experience of the operator. The authors describe a novel method using a fiber-needle–based swept-source optical coherence tomography (SSOCT) to identify epidural space. Methods: An optical fiber probe was placed into a hollow 18-gauge Tuohy needle. It was then inserted by an experienced anesthesiologist to continuously construct a series of two-dimensional SSOCT images by mechanically rotating the optical probe. To quantify this observation, both the average SSOCT signal intensities and their diagnostic potentials were assessed. The insertions were performed three times into both the lumbar and thoracic regions of five pigs using a paramedian approach. Results: A side-looking SSOCT is constructed to create a visual image of the underlying structures. The image criteria for the identification of the epidural space from the outside region were generated by the analysis of a training set (n = 100) of ex vivo data. The SSOCT image criteria for in vivo epidural space identification are high sensitivity (0.867 to 0.965) and high specificity (0.838 to 0.935). The mean value of the average signal intensities exhibits statistically significant differences (P < 0.01) and a high discriminatory capacity (area under curve = 0.88) between the epidural space and the outside tissues. Conclusions: This is the first study to introduce a SSOCT fiber probe embedded in a standard epidural needle. The authors anticipate that this technique will reduce the occurrence of failed epidural blocks and other complications such as dural punctures.


2020 ◽  
Vol 10 (14) ◽  
pp. 4936
Author(s):  
Pingping Jia ◽  
Hong Zhao ◽  
Yuwei Qin

A high-speed, high-resolution swept-source optical coherence tomography (SS-OCT) is presented for focusing lens imaging and a k-domain uniform algorithm is adopted to find the wave number phase equalization. The radius of curvature of the laser focusing lens was obtained using a curve-fitting algorithm. The experimental results demonstrate that the measuring accuracy of the proposed SS-OCT system is higher than the laser confocal microscope. The SS-OCT system has great potential for surface topography measurement and defect inspection of the focusing lens.


Sign in / Sign up

Export Citation Format

Share Document