Laser generation mechanism of submillimeter range electromagnetic oscillations on p-n junction

Author(s):  
V. M. Yakovenko
2001 ◽  
Vol 11 (PR2) ◽  
pp. Pr2-39-Pr2-42 ◽  
Author(s):  
M. Kado ◽  
T. Kawachi ◽  
N. Hasegawa ◽  
M. Tanaka ◽  
K. Sukegawa ◽  
...  

2004 ◽  
pp. 373-380 ◽  
Author(s):  
Timothy D. Solberg ◽  
Steven J. Goetsch ◽  
Michael T. Selch ◽  
William Melega ◽  
Goran Lacan ◽  
...  

Object. The purpose of this work was to investigate the targeting and dosimetric characteristics of a linear accelerator (LINAC) system dedicated for stereotactic radiosurgery compared with those of a commercial gamma knife (GK) unit. Methods. A phantom was rigidly affixed within a Leksell stereotactic frame and axial computerized tomography scans were obtained using an appropriate stereotactic localization device. Treatment plans were performed, film was inserted into a recessed area, and the phantom was positioned and treated according to each treatment plan. In the case of the LINAC system, four 140° arcs, spanning ± 60° of couch rotation, were used. In the case of the GK unit, all 201 sources were left unplugged. Radiation was delivered using 3- and 8-mm LINAC collimators and 4- and 8-mm collimators of the GK unit. Targeting ability was investigated independently on the dedicated LINAC by using a primate model. Measured 50% spot widths for multisource, single-shot radiation exceeded nominal values in all cases by 38 to 70% for the GK unit and 11 to 33% for the LINAC system. Measured offsets were indicative of submillimeter targeting precision on both devices. In primate studies, the appearance of an magnetic resonance imaging—enhancing lesion coincided with the intended target. Conclusions. Radiosurgery performed using the 3-mm collimator of the dedicated LINAC exhibited characteristics that compared favorably with those of a dedicated GK unit. Overall targeting accuracy in the submillimeter range can be achieved, and dose distributions with sharp falloff can be expected for both devices.


2021 ◽  
Vol 11 (12) ◽  
pp. 5440
Author(s):  
Elena A. Anashkina ◽  
Vitaly V. Dorofeev ◽  
Alexey V. Andrianov

Microresonator-based lasers in the two-micron range are interesting for extensive applications. Tm3+ ions provide high gain; therefore, they are promising for laser generation in the two-micron range in various matrices. We developed a simple theoretical model to describe Tm-doped glass microlasers generating in the 1.9–2 μm range with in-band pump at 1.55 μm. Using this model, we calculated threshold pump powers, laser generation wavelengths and slope efficiencies for different parameters of Tm-doped tellurite glass microspheres such as diameters, Q-factors, and thulium ion concentration. In addition, we produced a 320-μm tellurite glass microsphere doped with thulium ions with a concentration of 5·1019 cm−3. We attained lasing at 1.9 μm experimentally in the produced sample with a Q-factor of 106 pumped by a C-band narrow line laser.


Sign in / Sign up

Export Citation Format

Share Document