Functional imaging of muscle oxygenation and oxygen consumption in the knee extensor muscles during isometric contractions by spatially resolved near-infrared spectroscopy

2007 ◽  
Author(s):  
Khai Jun Kek ◽  
Takahiro Miyakawa ◽  
Nobuki Kudo ◽  
Katsuyuki Yamamoto
2005 ◽  
Vol 99 (2) ◽  
pp. 579-586 ◽  
Author(s):  
C. J. de Ruiter ◽  
M. D. de Boer ◽  
M. Spanjaard ◽  
A. de Haan

Fatigue resistance of knee extensor muscles is higher during voluntary isometric contractions at short compared with longer muscle lengths. In the present study we hypothesized that this would be due to lower energy consumption at short muscle lengths. Ten healthy male subjects performed isometric contractions with the knee extensor muscles at a 30, 60, and 90° knee angle (full extension = 0°). At each angle, muscle oxygen consumption (mV̇o2) of the rectus femoris, vastus lateralis, and vastus medialis muscle was obtained with near-infrared spectroscopy. mV̇o2 was measured during maximal isometric contractions and during contractions at 10, 30, and 50% of maximal torque capacity. During all contractions, blood flow to the muscle was occluded with a pressure cuff (450 mmHg). mV̇o2 significantly ( P < 0.05) increased with torque and at all torque levels, and for each of the three muscles mV̇o2 was significantly lower at 30° compared with 60° and 90° and mV̇o2 was similar ( P > 0.05) at 60° and 90°. Across all torque levels, average (± SD) mV̇o2 at the 30° angle for vastus medialis, rectus femoris, and vastus lateralis, respectively, was 70.0 ± 10.4, 72.2 ± 12.7, and 75.9 ± 8.0% of the average mV̇o2 obtained for each torque at 60 and 90°. In conclusion, oxygen consumption of the knee extensors was significantly lower during isometric contractions at the 30° than at the 60° and 90° knee angle, which probably contributes to the previously reported longer duration of sustained isometric contractions at relatively short muscle lengths.


1994 ◽  
Vol 76 (3) ◽  
pp. 1388-1393 ◽  
Author(s):  
R. A. De Blasi ◽  
M. Ferrari ◽  
A. Natali ◽  
G. Conti ◽  
A. Mega ◽  
...  

We applied near-infrared spectroscopy (NIRS) for the simultaneous measurement of forearm blood flow (FBF) and oxygen consumption (VO2) in the human by inducing a 50-mmHg venous occlusion. Eleven healthy subjects were studied both at rest and after hand exercise during vascular occlusion. FBF was also measured by strain-gauge plethysmography. FBF measured by NIRS was 1.9 +/- 0.8 ml.100 ml-1.min-1 at rest and 8.2 +/- 2.9 ml.100 ml-1.min-1 after hand exercise. These values showed a correlation (r = 0.94) with those obtained by the plethysmography. VO2 values were 4.6 +/- 1.3 microM O2 x 100 ml-1.min-1 at rest and 24.9 +/- 11.2 microM O2 x 100 ml-1.min-1 after hand exercise. The scatter of the FBF and VO2 values showed a good correlation between the two variables (r = 0.93). The results demonstrate that NIRS provides the particular advantage of obtaining the contemporary evaluation of blood flow and VO2, allowing correlation of these two variables by a single maneuver without discomfort for the subject.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5573
Author(s):  
Masatsugu Niwayama ◽  
Naoki Unno

Tissue oxygenation sensing at a few millimeters deep is useful for surgical and postoperative management. However, the measurement sensitivity at each depth and the proper sensor combination have not been clarified. Here, the measurement characteristics of oximetry by spatially resolved near-infrared spectroscopy were analyzed using Monte Carlo simulation and phantom experiment. From summing the sensitivities of each depth, it was quantitatively found that the measurement sensitivity curve had a peak, and the measurement depth can be adjusted by combining the two distances between the light source and the detector. Furthermore, the gastric tissue was 10–20% smaller in terms of measurement depth than the skin-subcutaneous tissue. A miniaturized oximeter was prototyped so that it could be used in combination with an endoscope or laparoscope. The optical probes consisted of light emitting diodes with wavelengths of 770 nm and 830 nm and photodetectors located 3 to 30 mm from the light source. Phantom experiments using the probes demonstrated the tendency of theoretical analysis. These results suggest the possibility of measuring tissue oxygen saturation with a selectable measurement depth. This selectable method will be useful for obtaining oxygenation information at a depth of 2–5 mm, which is difficult to measure using only laparoscopic surface imaging.


2014 ◽  
Vol 39 (5) ◽  
pp. 521-529 ◽  
Author(s):  
William M. Southern ◽  
Terence E. Ryan ◽  
Mary A. Reynolds ◽  
Kevin McCully

The purpose of this study was to assess the reproducibility of resting blood flow, resting oxygen consumption, and mitochondrial capacity in skeletal muscle using near-infrared spectroscopy (NIRS). We also determined the influence of 2 exercise modalities (ergometer and rubber exercise bands) on the NIRS measurements. Fifteen young, healthy participants (5 female, 10 male) were tested on 2 nonconsecutive occasions within an 8-day period. The NIRS device was placed on the medial gastrocnemius. Venous and arterial occlusions were performed to obtain blood flow and oxygen consumption. A series of repeated arterial occlusions was used to measure the recovery kinetics of muscle oxygen consumption after ∼7–10 s of voluntary plantar flexion exercise. Resting blood flow had mean coefficients of variation (CV) of 42% and 38% for bands and ergometer, respectively, and resting metabolism had mean CVs of 17% and 12% for bands and ergometer, respectively. The recovery time constant of oxygen consumption (day 1 bands and ergometer: 23.2 ± 3.7 s, 27.6 ± 6.5 s, respectively; day 2 bands and ergometer: 25.5 ± 5.4 s, 25.0 ± 4.9 s, respectively) had mean CVs of 10% and 11% for bands and ergometer, respectively. We conclude that measurements of oxygen consumption and mitochondrial capacity using NIRS can be obtained with good reproducibility.


Sign in / Sign up

Export Citation Format

Share Document