Study on a transient optical fiber high temperature measurement system

2009 ◽  
Author(s):  
Lulu Cai ◽  
Yusha Liu ◽  
Yutian Wang
2015 ◽  
Vol 738-739 ◽  
pp. 746-750
Author(s):  
Fei Xue ◽  
Fu Tao Dong

In order to improve the accuracy, range and instantaneity of high temperature measurement, a CCD (Charge Coupled Device) image temperature measurement system was designed based on multi-sensor truncated mean weighed fusion. Firstly, CCD temperature measurement range was expanded by 6 light filters. Then 15 colorimetric-sensors calculated the surface temperature of experimental molten pool. Finally, the more accurate fusion estimate of temperature value was acquired by using truncated mean weighted factors. The experiment results demonstrate that system have faster processing speed in the measurement of 800°C. The errors were kept within ±2%. This method is effective in improvement of system accuracy and instantaneity.