The Use of Normalized Cross-Correlation Analysis for Automatic Tendon Excursion Measurement in Dynamic Ultrasound Imaging

2013 ◽  
Vol 29 (2) ◽  
pp. 165-173 ◽  
Author(s):  
Stephen J. Pearson ◽  
Tim Ritchings ◽  
Ahmad S.A. Mohamed

The work describes an automated method of tracking dynamic ultrasound images using a normalized cross-correlation algorithm, applied to the patellar and gastrocnemius tendon. Displacement was examined during active and passive tendon excursions using B-mode ultrasonography. In the passive test where two regions of interest (2-ROI) were tracked, the automated tracking algorithm showed insignificant deviations from relative zero displacement for the knee (0.01 ± 0.04 mm) and ankle (–0.02 ± 0.04 mm) (P> .05). Similarly, when tracking 1-ROI the passive tests showed no significant differences (P> .05) between automatic and manual methods, 7.50 ± 0.60 vs 7.66 ± 0.63 mm for the patellar and 11.28 ± 1.36 vs 11.17 ± 1.35 mm for the gastrocnemius tests. The active tests gave no significant differences (P> .05) between automatic and manual methods with differences of 0.29 ± 0.04 mm for the patellar and 0.26 ± 0.01 mm for the gastrocnemius. This study showed that automatic tracking of in vivo displacement of tendon during dynamic excursion under load is possible and valid when compared with the standardized method. This approach will save time during analysis and enable discrete areas of the tendon to be examined.

2008 ◽  
Vol 24 (1) ◽  
pp. 75-82 ◽  
Author(s):  
Sabrina S.M. Lee ◽  
Gregory S. Lewis ◽  
Stephen J. Piazza

The accuracy of an algorithm for the automated tracking of tendon excursion from ultrasound images was tested in three experiments. Because the automated method could not be tested against direct measurements of tendon excursion in vivo, an indirect validation procedure was employed. In one experiment, a wire “phantom” was moved a known distance across the ultrasound probe and the automated tracking results were compared with the known distance. The excursion of the musculotendinous junction of the gastrocnemius during frontal and sagittal plane movement of the ankle was assessed in a single cadaver specimen both by manual tracking and with a cable extensometer sutured to the gastrocnemius muscle. A third experiment involved estimation of Achilles tendon excursion in vivo with both manual and automated tracking. Root mean squared (RMS) error was calculated between pairs of measurements after each test. Mean RMS errors of less than 1 mm were observed for the phantom experiments. For the in vitro experiment, mean RMS errors of 8–9% of the total tendon excursion were observed. Mean RMS errors of 6–8% of the total tendon excursion were found in vivo. The results indicate that the proposed algorithm accurately tracks Achilles tendon excursion, but further testing is necessary to determine its general applicability.


IEEE Access ◽  
2018 ◽  
Vol 6 ◽  
pp. 65199-65211
Author(s):  
Abdulla Mohamed ◽  
Phil F. Culverhouse ◽  
Angelo Cangelosi ◽  
Chenguang Yang

Sign in / Sign up

Export Citation Format

Share Document