Efficacy of Copper-Silver Ionization in Controlling Legionella in a Hospital Hot Water Distribution System: a German Experience

Legionella ◽  
2014 ◽  
pp. 419-424 ◽  
Author(s):  
Werner Mathys ◽  
Curro Palma Hohmann ◽  
Elisabeth Junge-Mathys
Author(s):  
Maria Coniglio ◽  
Margherita Ferrante ◽  
Mohamed Yassin

The purpose of this study is to report the experience of the implementation and application of a 3-year Water Safety Plan (WSP) together with the secondary disinfection of water by monochloramine to control and prevent healthcare-associated legionellosis in an Italian hospital strongly colonized by Legionella. Risk assessment was carried out by the WSP team. The main critical control points focused on in developing the WSP for the control of Legionella was the water distribution system. A sampling plan for the detection of Legionella was implemented. A widespread contamination of the hot water distribution system by L. pneumophila sg5 was found. Results after 3 years of the continuous disinfection of hot water with monochloramine indicate the eradication of Legionella. The implementation and application of a WSP in a hospital, together with the disinfection of the water distribution system with monochloramine, can be effective in controlling the growth of Legionella and in preventing nosocomial legionellosis.


2005 ◽  
Vol 52 (8) ◽  
pp. 177-180 ◽  
Author(s):  
R. Santos ◽  
F. Oliveira ◽  
J. Fernandes ◽  
S. Gonçalves ◽  
F. Macieira ◽  
...  

Mycobacteria have emerged as a major cause of opportunistic infections. Until the present, only a few studies have characterized mycobacteria present in the water distribution system of urban areas. In this study, we characterize these microorganisms in the Lisbon water distribution system. Our results indicate a high rate of positivities (90.5%) with mainly saprophytic mycobacteria. Around 63% of these results belong to strains of Mycobacterium gordonae indicating a generalized proliferation of this species in the Lisbon water distribution system. A total of 21.05% of the isolates are from M. kansasii, M. intracellulare and M. chelonae.


1979 ◽  
Vol 13 (11) ◽  
pp. 1420-1420
Author(s):  
David J. Schwartz ◽  
Jitendra Saxena ◽  
Frederick C. Kopfler

2007 ◽  
Author(s):  
Evelyn Baskin ◽  
William G Craddick ◽  
Roberto Lenarduzzi ◽  
Robert L Wendt ◽  
Professor Keith A. Woodbury

2021 ◽  
Vol 2021 (1) ◽  
pp. 23-28
Author(s):  
Peter Kapalo ◽  
◽  
Khrystyna Kozak ◽  
Khrystyna Myroniuk ◽  
◽  
...  

One of the main tasks around the world is to reduce energy consumption with constant consumer comfort. The hot water supply system uses a significant part of thermal energy and requires no less attention than the heating or ventilation system. The amount of heat loss from hot water distribution systems is of great importance for the energy consumption of buildings. In winter, part of this heat is used for space heating, in summer they are unused and is considered as lost heat. For this reason, this paper considers the influence of water velocity in the pipe, pipe size, and water temperature on the total heat losses in the insulated hot-water distribution system. The data are presented in tabular and graphical form. A graph of the dependence of the amount of heat loss on the temperature and velocity of hot water is obtained.


Sign in / Sign up

Export Citation Format

Share Document