scholarly journals Hot Water Distribution System Model Enhancements

2012 ◽  
Author(s):  
M Hoeschele ◽  
E Weitzel
2007 ◽  
Author(s):  
Evelyn Baskin ◽  
William G Craddick ◽  
Roberto Lenarduzzi ◽  
Robert L Wendt ◽  
Professor Keith A. Woodbury

2021 ◽  
Vol 2021 (1) ◽  
pp. 23-28
Author(s):  
Peter Kapalo ◽  
◽  
Khrystyna Kozak ◽  
Khrystyna Myroniuk ◽  
◽  
...  

One of the main tasks around the world is to reduce energy consumption with constant consumer comfort. The hot water supply system uses a significant part of thermal energy and requires no less attention than the heating or ventilation system. The amount of heat loss from hot water distribution systems is of great importance for the energy consumption of buildings. In winter, part of this heat is used for space heating, in summer they are unused and is considered as lost heat. For this reason, this paper considers the influence of water velocity in the pipe, pipe size, and water temperature on the total heat losses in the insulated hot-water distribution system. The data are presented in tabular and graphical form. A graph of the dependence of the amount of heat loss on the temperature and velocity of hot water is obtained.


2007 ◽  
Vol 28 (8) ◽  
pp. 1009-1012 ◽  
Author(s):  
Zhe Zhang ◽  
Carole McCann ◽  
Janet E. Stout ◽  
Steve Piesczynski ◽  
Robert Hawks ◽  
...  

In a 30-month prospective study, we evaluated the efficacy of chlorine dioxide to control Legionella organisms in a water distribution system of a hospital with 364 patient beds and 74 skilled nursing beds. The number of hot water specimens positive for Legionella organisms decreased from 12 (60%) of 20 to 2 (10%) of 20. An extended time (18 months) was needed to achieve a significant reduction in the rate of Legionella positivity among hot water specimens. At the time of writing, no cases of hospital-acquired Legionnaires disease have been detected at the hospital since the chlorine dioxide system was installed in January 2003. Use of chlorine dioxide was safe, based on Environmental Protection Agency limits regarding maximum concentrations of chlorine dioxide and chlorite.


2013 ◽  
Vol 437 ◽  
pp. 1062-1065 ◽  
Author(s):  
Peter Kapalo ◽  
Ladislav Böszörmenyi

At an actual increase energy price it is has impact cut-down energy requirement for preparation and distribution of hot water (HW). In the paper are presented results of exploration, where been evaluation effect interrupted operations distribution systems HW flat building. From presented analyses result - relative more savings heat is for long interrupted distribution systems and for little the number of flat in building.