A structural criterion for the biological compatibility of materials

BIOPHYSICS ◽  
2012 ◽  
Vol 57 (6) ◽  
pp. 825-827
Author(s):  
V. I. Denisov ◽  
S. D. Zakharov
1992 ◽  
Vol 20 (1) ◽  
pp. 52-60
Author(s):  
Gabriela Ciapetti ◽  
Elisabetta Cenni ◽  
Daniela Cavedagna ◽  
Loredana Pratelli ◽  
Arturo Pizzoferrato

Cell culture techniques are usually used in the field of biomaterials research and development in order to detect toxic components. Morphological assays are the most widely used methods and give the very first information about the biological compatibility of materials. Cell function assays give more quantitative data, but the comparison of data between different laboratories is difficult. Some of the cell culture methods that are used for biocompatibility studies are described briefly here, and results from our laboratory are reported. Despite some inherent limitations of the cell culture techniques, they are an accurate and reliable method of predicting the biological compatibility of materials to be implanted in vivo.


2010 ◽  
Vol 10 (2) ◽  
Author(s):  
Sigmar M. Rode ◽  
Bruno N. Cavalcanti ◽  
Vanessa Ferrielo ◽  
Miriam R. Faria ◽  
Nelson Villa

The purpose of the present study was evaluate the biological compatibility of materials used to manufacture prosthetic appliances. A heat-polymerized colorless resin and one visible light-cured denture base material were tested by the implantation of probe discs, in the dorsal connective tissue of 12 Wistar rats. The animals were sacrificed at 7, 14, 21 and 28 days after implantation. The specimens were prepared for light microscopy observation. It was noted that either after light microscopy observations, both resins demonstrated a good level of biocompatibility within the connective tissue of the dorsum of the animals studied.


Author(s):  
Shulin Wen ◽  
Jingwei Feng ◽  
A. Krajewski ◽  
A. Ravaglioli

Hydroxyapatite bioceramics has attracted many material scientists as it is the main constituent of the bone and the teeth in human body. The synthesis of the bioceramics has been performed for years. Nowadays, the synthetic work is not only focused on the hydroapatite but also on the fluorapatite and chlorapatite bioceramics since later materials have also biological compatibility with human tissues; and they may also be very promising for clinic purpose. However, in comparison of the synthetic bioceramics with natural one on microstructure, a great differences were observed according to our previous results. We have investigated these differences further in this work since they are very important to appraise the synthetic bioceramics for their clinic application.The synthetic hydroxyapatite and chlorapatite were prepared according to A. Krajewski and A. Ravaglioli and their recent work. The briquettes from different hydroxyapatite or chlorapatite powders were fired in a laboratory furnace at the temperature of 900-1300°C. The samples of human enamel selected for the comparison with synthetic bioceramics were from Chinese adult teeth.


2019 ◽  
Author(s):  
Jenna Franke ◽  
Benjamin Raliski ◽  
Steven Boggess ◽  
Divya Natesan ◽  
Evan Koretsky ◽  
...  

Fluorophores based on the BODIPY scaffold are prized for their tunable excitation and emission profiles, mild syntheses, and biological compatibility. Improving the water-solubility of BODIPY dyes remains an outstanding challenge. The development of water-soluble BODIPY dyes usually involves direct modification of the BODIPY fluorophore core with ionizable groups or substitution at the boron center. While these strategies are effective for the generation of water-soluble fluorophores, they are challenging to implement when developing BODIPY-based indicators: direct modification of BODIPY core can disrupt the electronics of the dye, complicating the design of functional indicators; and substitution at the boron center often renders the resultant BODIPY incompatible with the chemical transformations required to generate fluorescent sensors. In this study, we show that BODIPYs bearing a sulfonated aromatic group at the meso position provide a general solution for water-soluble BODIPYs. We outline the route to a suite of 5 new sulfonated BODIPYs with 2,6-disubstitution patterns spanning a range of electron-donating and -withdrawing propensities. To highlight the utility of these new, sulfonated BODIPYs, we further functionalize them to access 13 new, BODIPY-based voltage-sensitive fluorophores. The most sensitive of these BODIPY VF dyes displays a 48% ΔF/F per 100 mV in mammalian cells. Two additional BODIPY VFs show good voltage sensitivity (≥24% ΔF/F) and excellent brightness in cells. These compounds can report on action potential dynamics in both mammalian neurons and human stem cell-derived cardiomyocytes. Accessing a range of substituents in the context of a water soluble BODIPY fluorophore provides opportunities to tune the electronic properties of water-soluble BODIPY dyes for functional indicators.