Study of validity of autofluorescence-based incipient occlusal caries detection in vitro compared to DIAGNOdent pen

Laser Physics ◽  
2012 ◽  
Vol 22 (3) ◽  
pp. 614-619 ◽  
Author(s):  
H. H. Zhu ◽  
Q. G. Chen ◽  
B. Lin ◽  
H. Chen
2019 ◽  
Vol 43 (3) ◽  
pp. 173-179
Author(s):  
Murat Ünal ◽  
Arzu Koçkanat ◽  
Seniha Güler ◽  
Esra Gültürk

Aim: This in vitro study was aimed to investigate the performance of the new caries detection tools on the incipient occlusal caries. Study design: In our study, 100 permanent molar teeth, which were considered to have incipient, enamel caries (D1 and D2 threshold values) according to ICDAS II score. After the visual examination, caries measurements have been applied to all teeth by using DIAGNOdent pen (DP), CarieScan PRO (CP) and SoproLife camera (SC). In addition, in vitro examinations were repeated 2 weeks later. After sectioning and evaluation in stereomicroscope, the lesion depth was determined with histological criteria that are accepted for the gold standard for this research. Sensitivity, specificity, accuracy and area under the ROC curve were calculated at D1 and D2 thresholds. The intra-examiners' reproducibility were analysed using Cohen's kappa statistics and intraclass correlation coefficient (ICC). Results: Intra-examiner repeatability values varied from 0.94 to 0.99 and kappa values ranged from 0.90 to 0.99. While the highest sensitivity and specificity value showed for SC at D1 and D2 thresholds, CP presented the lowest values. The area under ROC curves (Az) varied from 0.70 to 0.99. ICDAS II showed the highest area under ROC curves (Az). Conclusions: ICDAS II, visual diagnostic method by itself is considered to sufficient in order to diagnose incipient occlusal caries. SC may be used as an alternative method for the ICDAS II, since its advantages by displaying caries lesion on the computer monitor, follow-up and motivation of the patients provided.


2021 ◽  
Author(s):  
Stavroula Michou ◽  
Mathias S. Lambach ◽  
Panagiotis Ntovas ◽  
Ana R. Benetti ◽  
Azam Bakhshandeh ◽  
...  

Abstract The use of 3D intraoral scanners (IOS) and software that can support automated detection and objective monitoring of oral diseases such as caries, tooth wear or periodontal diseases is increasingly receiving attention from researchers and industry. This study clinically validates an automated caries scoring system for occlusal caries detection and classification, previously developed for an IOS system featuring fluorescence (TRIOS 4, 3Shape TRIOS A/S, Denmark). Four algorithms (ALG1, ALG2, ALG3, ALG4) are assessed for the IOS; the first three are based only on fluorescence information, while ALG4 also takes into account the tooth color information. The diagnostic performance of these automated algorithms is compared with the diagnostic performance of the clinical visual examination, while histological assessment is used as reference. Additionally, possible differences between in vitro and in vivo diagnostic performance of the IOS system are investigated. The algorithms show comparable in vivo diagnostic performance to the visual examination. Only minor differences between their in vitro and in vivo diagnostic performance are noted. This novel IOS system exhibits encouraging performance for clinical application on occlusal caries detection and classification. Different approaches can be investigated for possible optimization of the system.


2000 ◽  
Vol 34 (2) ◽  
pp. 151-158 ◽  
Author(s):  
X.-Q. Shi ◽  
U. Welander ◽  
B. Angmar-Månsson

2020 ◽  
Vol 35 (9) ◽  
pp. 2049-2058
Author(s):  
Friederike Litzenburger ◽  
Alexander Lederer ◽  
Maximilian Kollmuß ◽  
Reinhard Hickel ◽  
Karl-Heinz Kunzelmann ◽  
...  

2006 ◽  
Vol 40 (3) ◽  
pp. 194-201 ◽  
Author(s):  
W.C. Souza-Zaroni ◽  
J.C. Ciccone ◽  
A.E. Souza-Gabriel ◽  
R.P. Ramos ◽  
S.A.M. Corona ◽  
...  

2006 ◽  
Vol 40 (2) ◽  
pp. 104-111 ◽  
Author(s):  
J. Kühnisch ◽  
R. Heinrich-Weltzien ◽  
M. Tabatabaie ◽  
L. Stösser ◽  
M.C.D.N.J.M. Huysmans

Sign in / Sign up

Export Citation Format

Share Document