scholarly journals Diode laser trabeculoplasty (DLT) for primary open-angle glaucoma and ocular hypertension.

1990 ◽  
Vol 74 (12) ◽  
pp. 743-747 ◽  
Author(s):  
D McHugh ◽  
J Marshall ◽  
T J Ffytche ◽  
P A Hamilton ◽  
A Raven
Ophthalmology ◽  
1993 ◽  
Vol 100 (11) ◽  
pp. 1614-1618 ◽  
Author(s):  
Anthony P. Moriarty ◽  
J. Dominic A. McHugh ◽  
Timothy J. ffytche ◽  
John Marshall ◽  
A.M. Peter Hamilton

2020 ◽  
Vol 36 (3) ◽  
Author(s):  
Asma Shams ◽  
Narain Das ◽  
Noman Rashid ◽  
M. Nasir Bhatti ◽  
Beenish Khan ◽  
...  

Purpose:  To compare the efficacy of the microwave pulse diode laser and argon laser trabeculoplasty in primary open angle glaucoma. Study Design:  Quasi experimental study. Place and Duration of Study:  Shaheed Mohtarma Benazir Bhutto Medical College Lyari and Sindh Government Lyari General Hospital, Karachi, from October, 2017 to March, 2018. Material and Methods:  One hundred and sixty patients, between 42 to 61 years with visual acuity of perception of light to 6/36 were enrolled. Patients diagnosed with POAG were included and patients with intraocular pressure of more than 40 mm Hg, previous glaucoma surgery or laser treatment and narrow angle on gonioscopy were excluded. Ophthalmic examination included visual acuity, slit lamp examination, fundus examination and visual field status using Humphrey perimeter. Patients were divided into two groups. Group A received microwave pulse diode laser (810) and Group B received argon laser trabeculoplasty. Average follow up period was 6 months. Success was assessed objectively by measuring intra ocular pressure and subjectively by visual acuity. Results:  The average time-period for each procedure was 15 ± 5 minutes. In Group A, mean IOP at first week, first month, third month and sixth month was 20.79, 16.34, 16.21and 16.09 mm Hg respectively. While in Group B, IOP at first week, first, third and sixth month was 16.52, 15.76, 13.62, and 12.54 mm Hg at (P < 0.001 in both groups). Conclusion:  Both microwave pulse diode laser and argon laser trabeculoplasty are effective in lowering intra ocular pressures in patients with primary open angle glaucoma.


2021 ◽  
Vol 14 (8) ◽  
pp. 1199-1204
Author(s):  
Gustavo Espinoza ◽  
◽  
Angelica Pedraza-Concha ◽  
Ignacio Rodríguez-Una ◽  
Maria Fernanda Acuna ◽  
...  

AIM: To describe the safety and efficacy of patterned laser trabeculoplasty (PLT) as an adjunctive treatment in primary open angle glaucoma (POAG) and ocular hypertension (OHT) after 18-month follow-up in Hispanic population. METHODS: A single-center, retrospective study was conducted. All patients with OHT or POAG undergoing PLT from June 2016 to August 2016 were included in the study. Investigated parameters were intraocular pressure (IOP), the number of IOP-lowering medications, best corrected visual acuity (BCVA), laser parameters and postoperative adverse events. Primary efficacy outcome measures were the proportion of eyes achieving an IOP reduction ≥20% at 18mo versus baseline medicated IOP or a reduction in the number of medications while maintaining IOP values. RESULTS: From 40 PLT-treated eyes (mean baseline IOP 20.3±1.7 mm Hg), 24 patients were analyzed (age 63.4±7.3y). The mean IOP reductions from baseline across visits (months 1, 3, 6, 9, 12, and 18) ranged from 14.1% to 20.8%. Success rate after 18-month follow-up was 61.7% with a mean IOP of 16±3.2 mm Hg (P<0.001). The number of glaucoma IOP-lowering medications per eye (preoperative 2.1±1.1 and postoperative 2.3±1.1, P=0.86) and the mean BCVA (preoperative 0.10±0.22 and postoperative 0.11±0.22 logMAR, P=0.42) remained stable. Adverse events comprised transitory IOP spikes in 4 eyes (10%) and peripheral anterior synechiae in 7 eyes (17.5%). CONCLUSION: Mid-term results of PLT show that this procedure may be an efficacious and safe technique to approach medically uncontrolled OHT or POAG patients.


Sign in / Sign up

Export Citation Format

Share Document