scholarly journals Influence of the pulmonary annulus diameter on pulmonary regurgitation and right ventricular pressure load after repair of tetralogy of Fallot

Heart ◽  
2002 ◽  
Vol 88 (5) ◽  
pp. 510-514 ◽  
Author(s):  
A Uebing
Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


2018 ◽  
Vol 315 (6) ◽  
pp. H1691-H1702 ◽  
Author(s):  
Pia Sjöberg ◽  
Johannes Töger ◽  
Erik Hedström ◽  
Per Arvidsson ◽  
Einar Heiberg ◽  
...  

Intracardiac hemodynamic forces have been proposed to influence remodeling and be a marker of ventricular dysfunction. We aimed to quantify the hemodynamic forces in patients with repaired tetralogy of Fallot (rToF) to further understand the pathophysiological mechanisms as this could be a potential marker for pulmonary valve replacement (PVR) in these patients. Patients with rToF and pulmonary regurgitation (PR) > 20% ( n = 18) and healthy control subjects ( n = 15) underwent MRI, including four-dimensional flow. A subset of patients ( n = 8) underwent PVR and MRI after surgery. Time-resolved hemodynamic forces were quantified using 4D-flow data and indexed to ventricular volume. Patients had higher systolic and diastolic left ventricular (LV) hemodynamic forces compared with control subjects in the lateral-septal/LV outflow tract ( P = 0.011 and P = 0.0031) and inferior-anterior ( P < 0.0001 and P < 0.0001) directions, which are forces not aligned with blood flow. Forces did not change after PVR. Patients had higher RV diastolic forces compared with control subjects in the diaphragm-right ventricular (RV) outflow tract (RVOT; P < 0.001) and apical-basal ( P = 0.0017) directions. After PVR, RV systolic forces in the diaphragm-RVOT direction decreased ( P = 0.039) to lower levels than in control subjects ( P = 0.0064). RV diastolic forces decreased in all directions ( P = 0.0078, P = 0.0078, and P = 0.039) but were still higher than in control subjects in the diaphragm-RVOT direction ( P = 0.046). In conclusion, patients with rToF and PR had LV hemodynamic forces less aligned with intraventricular blood flow compared with control subjects and higher diastolic RV forces along the regurgitant flow direction in the RVOT and that of tricuspid inflow. Remaining force differences in the LV and RV after PVR suggest that biventricular pumping does not normalize after surgery. NEW & NOTEWORTHY Biventricular hemodynamic forces in patients with repaired tetralogy of Fallot and pulmonary regurgitation were quantified for the first time. Left ventricular hemodynamic forces were less aligned to the main blood flow direction in patients compared with control subjects. Higher right ventricular forces were seen along the pulmonary regurgitant and tricuspid inflow directions. Differences in forces versus control subjects remain after pulmonary valve replacement, suggesting that altered biventricular pumping does not normalize after surgery.


2016 ◽  
Vol 4 (11) ◽  
pp. e12833 ◽  
Author(s):  
Mieke M. P. Driessen ◽  
Wei Hui ◽  
Bart H. Bijnens ◽  
Andreea Dragulescu ◽  
Luc Mertens ◽  
...  

2019 ◽  
Vol 21 (8) ◽  
pp. 906-913 ◽  
Author(s):  
Imran Rashid ◽  
Adil Mahmood ◽  
Tevfik F Ismail ◽  
Shamus O’Meagher ◽  
Shelby Kutty ◽  
...  

Abstract Aims The optimal timing for pulmonary valve replacement in asymptomatic patients with repaired Tetralogy of Fallot (rTOF) and pulmonary regurgitation remains uncertain but is often guided by increases in right ventricular (RV) end-diastolic volume. As cardiopulmonary exercise testing (CPET) performance is a strong prognostic indicator, we assessed which cardiovascular magnetic resonance (CMR) parameters correlate with reductions in exercise capacity to potentially improve identification of high-risk patients. Methods and results In all, 163 patients with rTOF (mean age 24.5 ± 10.2 years) who had previously undergone CMR and standardized CPET protocols were included. The indexed right and left ventricular end-diastolic volumes (RVEDVi, LVEDVi), right and left ventricular ejection fractions (RVEF, LVEF), indexed RV stroke volume (RVSVi), and pulmonary regurgitant fraction (PRF) were quantified by CMR and correlated with CPET-determined peak oxygen consumption (VO2) or peak work. On univariable analysis, there was no significant correlation between RVEDVi and PRF with peak VO2 or peak work (% Jones-predicted). In contrast, RVEF and RVSVi had significant correlations with both peak VO2 and peak work that remained significant on multivariable analysis. For a previously established prognostic peak VO2 threshold of &lt;27 mL/kg/min, receiver-operating characteristic curve analysis demonstrated a Harrell’s c of 0.70 for RVEF (95% confidence interval 0.61–0.79) with a sensitivity of 88% for RVEF &lt;40%. Conclusion In rTOF, CMR indices of RV systolic function are better predictors of CPET performance than RV size. An RVEF &lt;40% may be useful to identify prognostically significant reductions in exercise capacity in patients with varying degrees of RV dilatation.


1981 ◽  
Vol 81 (6) ◽  
pp. 897-905 ◽  
Author(s):  
Daniel A. Goor ◽  
Aram Smolinsky ◽  
Rephael Mohr ◽  
Joseph Caspi ◽  
Abraham Shem-Tov

2015 ◽  
Vol 17 (S1) ◽  
Author(s):  
Israel Valverde ◽  
Annalisa Paolino ◽  
Maria Pilar Serrano Gotarredona ◽  
Silvia Navarro ◽  
Nieves Romero ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document