Woven EndoBridge device for ruptured aneurysms: perioperative results of a US multicenter experience

2021 ◽  
pp. neurintsurg-2020-017105
Author(s):  
Gustavo M Cortez ◽  
Erinc Akture ◽  
Andre Monteiro ◽  
Adam S Arthur ◽  
Jeremy Peterson ◽  
...  

BackgroundThe Woven EndoBridge (WEB) device is approved in the USA for treatment of unruptured wide-neck bifurcation aneurysms. However, the safety and effectiveness of the WEB device in the treatment of ruptured intracranial aneurysms is not clear. We aim to evaluate the perioperative safety and effectiveness of the WEB device in patients with ruptured intracranial aneurysms.MethodsThis retrospective study, conducted at eight centers in the USA, included patients with ruptured intracranial aneurysms treated with the WEB device in the setting of subarachnoid hemorrhage (SAH). Safety outcomes included intraoperative complications such as vessel perforation, thromboembolic events, and postoperative hemorrhagic or thromboembolic complications based on radiologic imaging. The primary effectiveness outcome was adequate (complete and neck remnant) aneurysm occlusion, according to the Raymond–Roy classification.ResultsA total of 91 patients with 94 ruptured intracranial aneurysms were included (mean age 57.7±15.2 years; 68.1% women; 82.9% wide-necked). Aneurysms were located in the anterior communicating artery (42/94, 44.6%), middle cerebral artery (16/94, 17%), and basilar artery (15/94, 16%). Adequate occlusion was achieved in 48.8% (41/84) and 80.0% (40/50) at discharge and last follow-up (mean of 3.4 months), respectively. At discharge, procedural-related morbidity was 3.3% (3/91) and there was no procedure-related mortality. No re-rupture or delayed aneurysm rupture was observed.ConclusionsThis study demonstrates the perioperative safety and effectiveness of the WEB device for the treatment of patients with ruptured intracranial aneurysms in the setting of SAH, with low periprocedural morbidity and mortality. Long-term follow-up is warranted.

2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


2021 ◽  
pp. 159101992110267
Author(s):  
Yong Xie ◽  
Huan Tian ◽  
Bin Xiang ◽  
Jian Liu ◽  
Hua Xiang

Background and objective The clinical outcome and angiographic outcome data of Woven EndoBridge (WEB) device for the treatment of ruptured intracranial aneurysms (IAs) are limited. We conducted a meta-analysis of the latest literature on the WEB device in the treatment of ruptured IAs. Methods A comprehensive literature search of 4 databases (PubMed, Web of Science, Cochrane library, and Embase) was conducted for studies published from January 1, 2010 to December 31, 2020. Two reviewers independently extracted variables (aneurysm and patient characteristics) using a prespecified data-collection sheet. Outcomes studied included initial and latest follow-up angiographic outcomes, technical success rate, perioperative mortality, retreated rate, perioperative re-bleeding, complication, intraoperative rupture, favorable neurologic outcome at discharge. We used random-effects model to pool the data. Results We finally presented the results of 7 articles including 276 patients with 283 aneurysms. Initial complete and adequate occlusion rate were 38% (95% CI, 25%–50%) and 98% (95% CI, 95%–100%), respectively. Latest follow-up complete and adequate occlusion rate were 61% (95% CI, 46%–75%) and 91% (95% CI, 84%–98%), respectively.Technical success rate was 99% (95% CI, 98%–100%). Perioperative mortality rates and perioperative re-bleeding rate were 9% (95% CI, 3%–15%) and 1% (95% CI, 0%–2%), respectively. Retreated rate was 6% (95% CI, 3%–10%). Overall and WEB treatment-related thromboembolic complication was 10% (95% CI, 6%–13%) and 7% (95% CI, 2%–12%), respectively. Intraoperative rupture rate was 3% (95% CI, 0%–6%). Conclusion Endovascular treatment of ruptured IAs with the WEB device has a good safety profile and an acceptable aneurysm occlusion rate.


2021 ◽  
Author(s):  
Daniel M Heiferman ◽  
Jeremy C Peterson ◽  
Kendrick D Johnson ◽  
Vincent N Nguyen ◽  
David Dornbos ◽  
...  

Abstract The Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, California) is an intrasaccular flow disruptor used for the treatment of both unruptured and ruptured intracranial aneurysms. WEB has been shown to have 54% complete and 85% adequate aneurysm occlusion rates at 1-yr follow-up.1 Residual and recurrent ruptured aneurysms have been shown to have a higher risk of re-rupture than completely occluded aneurysms.2 With increased utilization of WEB in the United States, optimizing treatment strategies of residual aneurysms previously treated with the WEB device is essential, including surgical clipping.3,4 Here, we present an operative video demonstrating the surgical clip occlusion of previously ruptured middle cerebral artery and anterior communicating artery aneurysms that had been treated with the WEB device and had sizable recurrence on follow-up angiography. Informed consent was obtained from both patients. Lessons learned include the following: (1) the WEB device is highly compressible, unlike coils; (2) proximal WEB marker may interfere with clip closure; (3) no evidence of WEB extrusion into the subarachnoid space; (4) no more scarring than expected in ruptured cases; and (5) clipping is a feasible option for treating WEB recurrent or residual aneurysms.


2015 ◽  
Vol 21 (4) ◽  
pp. 462-469 ◽  
Author(s):  
Patricia Bozzetto Ambrosi ◽  
Benjamin Gory ◽  
Rotem Sivan-Hoffmann ◽  
Roberto Riva ◽  
Francesco Signorelli ◽  
...  

Background The WEB device is a recent intrasaccular flow disruption technique developed for the treatment of wide-necked intracranial aneurysms. To date, a single report on the WEB Single-Layer (SL) treatment of intracranial aneurysms has been published with 1-months' safety results. The aim of this study is to report our experience and 6-month clinical and angiographic follow-up of endovascular treatment of wide-neck aneurysm with the WEB SL. Methods Ten patients with 10 unruptured wide-necked aneurysms were prospectively enrolled in this study. Feasibility, intraoperative and postoperative complications, and outcomes were recorded. Immediate and 6-month clinical and angiographic results were evaluated. Results Failure of WEB SL placement occurred in two cases. Eight aneurysms were successfully treated using one WEB SL without additional treatment. Three middle cerebral artery, four anterior communicating artery, and one basilar artery aneurysms were treated. Average dome width was 7.5 mm (range 5.4–10.7 mm), and average neck size was 4.9 mm (range 2.6–6.5 mm). No periprocedural complication was observed, and morbi-mortality at discharge and 6 months was 0.0%. Angiographic follow-up at 6 months demonstrated complete aneurysm occlusion in 2/8 aneurysms, neck remnant in 5/8 aneurysms, and aneurysm remnant in 1/8 aneurysm. Conclusions From this preliminary study, treatment of bifurcation intracranial aneurysms using WEB SL is feasible. WEB SL treatment seems safe at 6 months; however, the rate of neck remnants is not negligible due to compression of the WEB SL. Further technical improvements may be needed in order to ameliorate the occlusion in the WEB SL treatment.


2016 ◽  
Vol 9 (4) ◽  
pp. 411-417 ◽  
Author(s):  
Christin Clajus ◽  
Christoph Strasilla ◽  
Tom Fiebig ◽  
Vojtech Sychra ◽  
David Fiorella ◽  
...  

IntroductionThe Woven EndoBridge (WEB) is a novel device for the treatment of wide-necked intracranial bifurcation aneurysms. The present series demonstrates our ‘real-world experience’ in the use of all iterations of WEB devices (available in Europe) in ruptured and unruptured aneurysms.MethodsWe analyzed our all-inclusive cerebrovascular database for patients treated with the WEB device between October 2010 and May 2015. Anatomic and clinical results are reported for all patients.ResultsOne hundred and eight patients with 114 intracranial aneurysms were included in the series. Forty-seven aneurysms (41.2%) were ruptured. Eighty-six patients received angiographic and clinical follow-up after a mean of 13.4 months. One hundred and ten of 114 WEB devices (96.5%) were deployed successfully. Thromboembolic complications occurred in 11 of 110 interventions (10.0%), with a new permanent deficit in one patient. Re-rupture after WEB treatment was detected in two aneurysms (4.3%), which had both initially presented with subarachnoid hemorrhage. Angiographic follow-up revealed adequate occlusion in 68 of 90 aneurysms (75.6%). Fifteen aneurysms required retreatment.ConclusionsThis series confirms a high level of safety and efficacy of the WEB device for the treatment of wide-necked intracranial aneurysms.


2017 ◽  
Vol 10 (7) ◽  
pp. 629-633 ◽  
Author(s):  
Matthias Gawlitza ◽  
Sebastien Soize ◽  
Anne-Christine Januel ◽  
Cristian Mihalea ◽  
Georgios-Emmanouil Metaxas ◽  
...  

BackgroundThe safety and efficacy of the Woven EndoBridge (WEB) for the treatment of naïve intracranial aneurysms has been confirmed.PurposeTo analyze the safety and efficacy of the WEB in the treatment of recurrent aneurysms.MethodsAnatomical and clinical results in consecutive patients with a recurrent aneurysm, who were treated using the WEB device in two French neurointerventional centers, were evaluated.ResultsSeventeen patients with 17 aneurysms were included. Treatment was feasible in 16 patients. In seven patients (41.2%), ancillary devices were used. Permanent morbidity due to a thromboembolic complication occurred in one patient (5.9%). There was no mortality. Follow-up angiographic studies were available for 15 patients after a mean of 12.1±6.1 months. Rates of complete occlusion, neck remnant, and aneurysm remnant were 33.3%, 40.0%, and 26.7%, respectively.ConclusionsTreatment of recurrent aneurysms using the WEB device may be reasonably safe and effective.


2016 ◽  
Vol 22 (3) ◽  
pp. 299-303 ◽  
Author(s):  
Yong-Hong Ding ◽  
Daying Dai ◽  
Dana Schroeder ◽  
Ramanathan Kadirvel ◽  
David F Kallmes

The dual-layer Woven EndoBridge (WEB) device (WEB II) is designed to improve the performance of the first-generation WEB device. This study was performed to evaluate the acute and chronic performance of WEB II for aneurysm occlusion in an elastase-induced aneurysm model in rabbits. We implanted WEB II devices in 36 elastase-induced aneurysms and followed up for one, three, six, and 12 months. Degree of aneurysm occlusion at follow-up was graded on the Web Occlusion Scale (WOS): Grade A, complete aneurysm occlusion; Grade B, complete occlusion with recess filling; Grade C, residual neck filling; and Grade D, residual aneurysm filling. Hematoxylin and eosin staining was performed for histological assessment of aneurysm healing. Grades A, B, C, and D aneurysm occlusion at one-month follow-up were noted in three (17%), three (17%), eight (44%), and four (22%) of 18 cases, respectively. At the three-month time point Grades A, B, C, and D were shown in two (33%), two (33%), one (17%), and one (17%) aneurysms. Six months after treatment, one (17%), two (33%), two (33%), and one (17%) cases demonstrated Grades A, B, C, and D occlusion. At the 12-month time point, Grades B, C, and D were shown in three (50%), two (33%), and one (17%) aneurysms. Histologic evaluation showed progressive thrombus organization within aneurysm lumen from one to 12 months. These results indicated that the WEB II device can achieve high rates of aneurysm occlusion over time in experimental aneurysms.


2018 ◽  
Vol 11 (4) ◽  
pp. 386-389 ◽  
Author(s):  
Cristian Mihalea ◽  
Simon Escalard ◽  
Jildaz Caroff ◽  
Léon Ikka ◽  
Aymeric Rouchaud ◽  
...  

BackgroundWoven EndoBridge (WEB) deployment remains challenging in aneurysms with a complex shape or orientation.ObjectiveTo show that embolization of wide-neck bifurcation aneurysms using the WEB device balloon remodeling-assisted technique is a feasible and elegant endovascular solution compared with other techniques, such as balloon remodeling or stent-assisted coiling.Materials and methods10 cases (10 aneurysms in 9 patients) of balloon remodeling-assisted WEB treatment of unruptured complex bifurcation aneurysms were treated in our institution and retrospectively analyzed. Details of clinical presentations, technical details, perioperative and postoperative complications, and outcomes were collected. Immediate and long-term angiographic results were also evaluated.ResultsAneurysms included six middle cerebral artery aneurysms, one anterior communicating artery aneurysm, one posterior communicating artery aneurysm, one basilar artery aneurysm, and one T-shaped carotid aneurysm. Mean dome width was 6.55 mm, mean neck size 4.5 mm, mean height 4.79 mm, and mean dome-to-neck ratio was 1:1.46. Treatment was performed exclusively with the balloon remodeling-assisted WEB technique in all cases. The device was successfully deployed in every case. Periprocedural thromboembolic or hemorrhagic events did not occur. The modified Rankin Scale score at discharge was 0 for all patients. At mid-term or long-term angiographic follow-up, adequate occlusion was observed in 7 aneurysms from 8 controlled cases (87.5%), and one patient (2 aneurysms) did not have angiographic follow-up.ConclusionThe balloon remodeling-assisted WEB technique seems to be a safe and effective solution for endovascular treatment of unruptured wide-neck bifurcation aneurysms with specific complex anatomy. However, further studies are needed to evaluate the rate of complications and long-term efficacy.


Neurosurgery ◽  
2020 ◽  
Vol 87 (1) ◽  
pp. E16-E22 ◽  
Author(s):  
Fadi Al Saiegh ◽  
David Hasan ◽  
Nikolaos Mouchtouris ◽  
Mario Zanaty ◽  
Ahmad Sweid ◽  
...  

Abstract BACKGROUND Coil embolization of ruptured bifurcation aneurysms is challenging and often necessitates adjunctive stenting, which requires antiplatelet therapy in the setting of subarachnoid hemorrhage (SAH). The Woven EndoBridge (WEB; Terumo) device is an alternative self-expanding 3D mesh that does not require antiplatelet agents. However, its use has been mostly reserved for unruptured aneurysms. OBJECTIVE To assess the safety and feasibility of ruptured aneurysm treatment with the WEB. METHODS Retrospective analysis of 9 SAH patients with 11 aneurysms that were treated with the WEB device at 2 institutions after FDA approval. RESULTS Hunt and Hess grades were III and IV in 4 (44%) each and V in 1 (11%). All patients were treated within 24 h of hospitalization, and a single WEB was used in all but one aneurysm. Aneurysms treated were 3 basilar tip, 2 anterior communicating artery, 2 posterior inferior cerebellarartery, 1 middle cerebral artery, 1 carotid-ophthalmic artery, 1 posterior communicating artery, and 1 vertebrobasilar junction. Mean aneurysm height and width were 6.2 ± 2.2 mm (range: 3-10) and 5.6 ± 3.0 mm (range: 3.3-14), respectively. Mean dome-to-neck ratio was 1.7 ± 0.8 (range: 1.0-3.8). There was one intraoperative rupture that occurred because of device dislodgement and was managed with embolization. There were no treatment-related mortalities and no re-rupture after securement of the aneurysms with the WEB. CONCLUSION Our preliminary experience indicates that the WEB device can be used safely for ruptured aneurysms of various sizes in the anterior and posterior circulation. Larger series with long-term follow-up are necessary to confirm our findings.


2017 ◽  
Vol 10 (2) ◽  
pp. 127-132 ◽  
Author(s):  
Benjamin Mine ◽  
Alexandra Goutte ◽  
Denis Brisbois ◽  
Boris Lubicz

PurposeTo evaluate the clinical and anatomical results of treatment of intracranial aneurysms (IA) with the Woven EndoBridge (WEB) device, with emphasis on mid term and long term follow-up.MethodsBetween November 2010 and November 2015, we retrospectively identified, in our prospectively maintained database, all patients treated by WEB device placement for an IA at three institutions. Clinical charts, procedural data, and angiographic results were reviewed.Results48 patients with 49 IAs were identified. There were 35 women and 13 men with a mean age of 57 years (range 35–76 years). All IA were wide necked. Mean aneurysm size was 8.6 mm. There were 44 unruptured IA and 5 ruptured IA. During endovascular treatment (EVT), adjunctive devices were used in 22.4% of procedures. A good clinical outcome (modified Rankin Scale score ≤2) was achieved in 44/48 patients (92%). There was no mortality. Mean follow-up was 25 months (range 3–72 months; median 24 months). Between mid term and long term follow-up, occlusion was stable in 19/23 IA (82.6%), improved in 2/23 IA (8.7%), and worsened in 2/23 IA (8.7%). Retreatment was performed in 8/49 IA (16.3%). At the latest available follow-up, there were 34/47 (72.3%) complete occlusions and 13/47 (27.7%) neck remnants.ConclusionsOur study suggests that EVT of IA with the WEB device provides adequate and stable long term occlusion.


Sign in / Sign up

Export Citation Format

Share Document