scholarly journals EP08 The power of information: WEB device in-vivo evaluation with endovascular high frequency optical coherence tomography (HF-OCT) technology: First in humans experience

Author(s):  
B Pabon ◽  
M Patiño ◽  
V Torres ◽  
N Serna ◽  
J Pelaez ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chenchen Ren ◽  
Xianxu Zeng ◽  
Zhongna Shi ◽  
Chunyan Wang ◽  
Huifen Wang ◽  
...  

AbstractIn this prospective study of an in-vivo cervical examination using optical coherence tomography (OCT), we evaluated the diagnostic value of non-invasive and real-time OCT in cervical precancerous lesions and cancer diagnosis, and determined the characteristics of OCT images. 733 patients from 5 Chinese hospitals were inspected with OCT and colposcopy-directed biopsy. The OCT images were compared with the histological sections to find out the characteristics of various categories of lesions. The OCT images were also interpreted by 3 investigators to make a 2-class classification, and the results were compared against the pathological results. Various structures of the cervical tissue were clearly observed in OCT images, which matched well with the corresponding histological sections. The OCT diagnosis results delivered a sensitivity of 87.0% (95% confidence interval, CI 82.2–90.7%), a specificity of 84.1% (95% CI 80.3–87.2%), and an overall accuracy of 85.1%. Both good consistency of OCT images and histological images and satisfactory diagnosis results were provided by OCT. Due to its features of non-invasion, real-time, and accuracy, OCT is valuable for the in-vivo evaluation of cervical lesions and has the potential to be one of the routine cervical diagnosis methods.


Heart ◽  
2011 ◽  
Vol 97 (Suppl 3) ◽  
pp. A17-A17
Author(s):  
S. Yanli ◽  
H. Sining ◽  
T. Jinwei ◽  
J. Haibo ◽  
M. Lingbo ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Kornelia Schuetzenberger ◽  
Martin Pfister ◽  
Alina Messner ◽  
Vanessa Froehlich ◽  
Gerhard Garhoefer ◽  
...  

Abstract Optical coherence tomography (OCT) and high-frequency ultrasound (HFUS), two established imaging modalities in the field of dermatology, were evaluated and compared regarding their applicability for visualization of skin tissue morphology and quantification of murine intradermal structures. The accuracy and reproducibility of both methods were assessed ex vivo and in vivo using a standardized model for intradermal volumes based on injected soft tissue fillers. OCT revealed greater detail in skin morphology, allowing for detection of single layers due to the superior resolution. Volumetric data measured by OCT (7.9 ± 0.3 μl) and HFUS (7.7 ± 0.5 μl) were in good agreement and revealed a high accuracy when compared to the injected volume of 7.98 ± 0.8 µl. In vivo, OCT provided a higher precision (relative SD: 26% OCT vs. 42% HFUS) for the quantification of intradermal structures, whereas HFUS offered increased penetration depth enabling the visualization of deeper structures. A combination of both imaging technologies might be valuable for tumor assessments or other dermal pathologies in clinical settings.


Stroke ◽  
2020 ◽  
Vol 51 (Suppl_1) ◽  
Author(s):  
Ajit S Puri ◽  
Giovanni Ughi ◽  
Robert M King ◽  
Matthew Gounis

Introduction: Optical coherence tomography (OCT) has played an important role in the diagnosis and treatment guidance in coronary artery disease. However, existing OCT systems are not suitable for routine neurovascular applications due to the size and tortuosity of the arteries. Hypothesis: We seek to demonstrate a prototype high-frequency OCT (HF-OCT) capable of high-resolution imaging in simulated cerebrovascular anatomy. Methods: A low-profile HF-OCT system was constructed with an image resolution approaching 10μm. Using an in vitro, patient-specific model of the circle of Willis with circulating porcine blood, we characterized the delivery of the device and ability to image in a tortuous path. Also, human cadaver intracranial atherosclerosis plaques were imaged with HF-OCT and assessed by an expert imager. Finally, neurovascular devices were implanted in 8 pigs (Fig 1) and HF-OCT imaging was compared with gold-standard DSA and CT. Results: In the phantom, optimal blood clearance was achieved through an intermediate catheter (5 Fr Navien) with infusion of contrast at 5 ml/s in the internal carotid and basilar artery, and 3 ml/sec in the MCA. The in vivo study demonstrated that both malapposition of devices or thrombus formation along the device surface could be reliably diagnosed among 3 reviewers (Fleiss’s kappa of 0.87 and 0.9, respectively). This agreement was superior to DSA and CT. Imaging in tortuous swine brachial showed in all cases imaging free of artifacts, uniform illumination and ability to visualize vessel wall layers. Plaque types including ‘lipid pools’, fibrotic, and calcific tissue from cadaver specimens of ICAD could be adequately depicted by HF-OCT. Conclusion: In vitro, in vivo and ex vivo characterization of a novel HF-OCT device has shown it is capable of imaging in the tortuous intracranial vascular anatomy. This technology has to potential to aid in the diagnosis of cerebrovascular disease and guide optimal endovascular treatment.


Sign in / Sign up

Export Citation Format

Share Document