scholarly journals Distortion-Oblivious Algorithms for Minimizing Flow Time

2022 ◽  
pp. 252-274
Author(s):  
Yossi Azar ◽  
Stefano Leonardi ◽  
Noam Touitou
Author(s):  
Virgil Peck ◽  
W. L. Carter

Any electron microscopical study of the morphology of bulk polymers has throughout the years been hampered by the lack of any real ability to produce meaningful surface variations for replication. True etching of polymers should show crystalline and amorphous regions in some form of relief. The use of solvents, acids, organic vapors, and inert ion bombardment to etch samples has proved to be useful only in limited applications. Certainly many interpretations of these results are subject to question.The recent use of a radiofrequency (R. F.) plasma of oxygen to degrade and remove organic material with only minor heating has opened a new possibility for etching polymers. However, rigid control of oxygen flow, time, current, and sample position are necessary in order to obtain reproducible results. The action is confined to surface layers; the molecular weight of the polymer residue after heavy etching is the same as the molecular weight of the polymer before attack, within the accuracy of measurement.


2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Jon-Émile S. Kenny ◽  
Igor Barjaktarevic ◽  
David C. Mackenzie ◽  
Andrew M. Eibl ◽  
Matthew Parrotta ◽  
...  

Abstract Background Change of the corrected flow time (Ftc) is a surrogate for tracking stroke volume (SV) in the intensive care unit. Multiple Ftc equations have been proposed; many have not had their diagnostic characteristics for detecting SV change reported. Further, little is known about the inherent Ftc variability induced by the respiratory cycle. Materials and methods Using a wearable Doppler ultrasound patch, we studied the clinical performance of 11 Ftc equations to detect a 10% change in SV measured by non-invasive pulse contour analysis; 26 healthy volunteers performed a standardized cardiac preload modifying maneuver. Results One hundred changes in cardiac preload and 3890 carotid beats were analyzed. Most of the 11 Ftc equations studied had similar diagnostic attributes. Wodeys’ and Chambers’ formulae had identical results; a 2% change in Ftc detected a 10% change in SV with a sensitivity and specificity of 96% and 93%, respectively. Similarly, a 3% change in Ftc calculated by Bazett’s formula displayed a sensitivity and specificity of 91% and 93%. FtcWodey had 100% concordance and an R2 of 0.75 with change in SV; these values were 99%, 0.76 and 98%, 0.71 for FtcChambers and FtcBazetts, respectively. As an exploratory analysis, we studied 3335 carotid beats for the dispersion of Ftc during quiet breathing using the equations of Wodey and Bazett. The coefficient of variation of Ftc during quiet breathing for these formulae were 0.06 and 0.07, respectively. Conclusions Most of the 11 different equations used to calculate carotid artery Ftc from a wearable Doppler ultrasound patch had similar thresholds and abilities to detect SV change in healthy volunteers. Variation in Ftc induced by the respiratory cycle is important; measuring a clinically significant change in Ftc with statistical confidence requires a large sample of beats.


CHEST Journal ◽  
2016 ◽  
Vol 150 (4) ◽  
pp. 297A
Author(s):  
Irene Ma ◽  
Joshua Caplin ◽  
Aftab Azad ◽  
Christina Wilson ◽  
Michael Fifer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document