Chronic metformin intake improves anaerobic but not aerobic capacity in healthy rats

2020 ◽  
Vol 98 (1) ◽  
pp. 23-28
Author(s):  
Gustavo Gomes de Araujo ◽  
Sara Learsi ◽  
Victor José Bastos-Silva ◽  
Terezinha Ataide ◽  
Adriano Eduardo Lima-Silva

The effect of chronic metformin intake on aerobic and anaerobic capacity was examined in healthy rats. Twenty rats completed 10 days of metformin (MET) ingestion (250 mg). After this period, the animals performed four high-intensity bouts until exhaustion at 9%, 11%, 13%, and 15% of body mass (BM) in swimming, separated by 24 h, with prior metformin (250 mg) or placebo (PL). The critical load (CL) and anaerobic work capacity (AWC – W′) were calculated and considered aerobic and anaerobic capacity, respectively. There was no difference in CL between the MET and PL groups (p > 0.05). The AWC – W′ was higher in the MET group than in the PL group (p = 0.004). Time until exhaustion (seconds) at all bouts were higher (p < 0.004) in the MET group (9% of BM = 434.5 ± 267.3, 11% of BM = 269.6 ± 214.2, 13% of BM = 174.0 ± 40.9, 15% of BM = 146.6 ± 15.9) compared to the PL group (9% of BM = 96.4 ± 22.3, 11% of BM = 65.5 ± 13.4, 13% of BM = 51.1 ± 5.5, 15% of BM = 40.8 ± 7.5). Glucose concentration was higher at 90 and 120 min than at 0 and 30 min for the MET group (intragroup) during the oral glucose test tolerance; there was no difference between the MET and PL groups for area under curve. MET ingestion enhances AWC – W′ and times to exhaustion but not aerobic capacity.

2010 ◽  
Vol 22 (3) ◽  
pp. 454-466 ◽  
Author(s):  
Erwan Leclair ◽  
Benoit Borel ◽  
Delphine Thevenet ◽  
Georges Baquet ◽  
Patrick Mucci ◽  
...  

This study first aimed to compare critical power (CP) and anaerobic work capacity (AWC), to laboratory standard evaluation methods such as maximal oxygen uptake (V̇O2max) and maximal accumulated oxygen deficit (MAOD). Secondly, this study compared child and adult CP and AWC values. Subjects performed a maximal graded test to determine V̇O2max and maximal aerobic power (MAP); and four constant load exercises. In children, CP (W.kg−1) was related to V̇O2max (ml.kg−1.min−1; r = .68; p = .004). AWC (J.kg−1) in children was related to MAOD (r = .58; p = .018). Children presented lower AWC (J.kg−1; p = .001) than adults, but similar CP (%MAP) values. CP (%MAP and W.kg−1) and AWC (J.kg−1) were significantly related to laboratory standard evaluation methods but low correlation indicated that they cannot be used interchangeably. CP (%MAP) was similar in children and adults, but AWC (J.kg−1) was significantly lower in children. These conclusions support existing knowledge related to child-adults characteristics.


Author(s):  
Koichi HIROTA ◽  
Toshio ASAMI ◽  
Hiroshi TOYODA ◽  
Daisen SHIMAZU

Ob Gyn News ◽  
2005 ◽  
Vol 40 (8) ◽  
pp. 15
Author(s):  
TIMOTHY F. KIRN

2012 ◽  
Vol 24 (2) ◽  
pp. 262-274
Author(s):  
Kerry McGawley ◽  
Erwan Leclair ◽  
Jeanne Dekerle ◽  
Helen Carter ◽  
Craig A. Williams

The Wingate cycle test (WAnT) is a 30-s test commonly used to estimate anaerobic work capacity (AWC). However, the test may be too short to fully deplete anaerobic energy reserves. We hypothesized that a 90-s all-out isokinetic test (ISO_90) would be valid to assess both aerobic and anaerobic capacities in young females. Eight girls (11.9 ± 0.5 y) performed an exhaustive incremental test, a WAnT and an ISO_90. Peak VO2 attained during the ISO_90 was significantly greater than VO2peak. Mean power, end power, fatigue index, total work done and AWC were not significantly different between the WAnT and after 30 s of the 90-s test (i.e., ISO_30). However, 95% limits of agreement showed large variations between the two tests when comparing all anaerobic parameters. It is concluded that an ISO-90 may be a useful test to assess aerobic capacity in young girls. However, since the anaerobic parameters derived from the ISO_30 did not agree with those derived from a traditional WAnT, the validity of using an ISO_90 to assess anaerobic performance and capacity within this population group remains unconfirmed.


2021 ◽  
Author(s):  
Manuel Angulo ◽  
Alejandra Polanco ◽  
Luis Muñoz

Abstract Pacing strategies are used in cycling to optimize the power delivered by the cyclist during a race. Gains in race time have been obtained when using these strategies compared to self-paced approaches. For this reason, this study is focused on revising the effect that the variation of the cyclist’s parameters has on the pacing strategy and its results. A numeric method was used to propose pacing strategies for a cyclist riding on an ascending 3.7 km route with a constant 6.26% road grade. The method was validated and then implemented to study the effect of aerobic and anaerobic power delivery capacity, mass, and drag area on the pacing strategies and their corresponding estimated race times. The results showed that modifying 1% of the aerobic capacity or cyclist mass value led to a change of 1% on the race time. Modifying 1% the anaerobic capacity and the drag area led to changes of 0.03% and 0.02% on the race time, respectively. These results are strongly dependent on the route characteristics. It was concluded that for the studied route (constantly ascending), the variation of the cyclist’s aerobic capacity influences the pacing strategy (i.e., the power delivery over the distance). The anaerobic capacity and mass of the cyclist also influence the pacing strategy to a lesser extent.


Sign in / Sign up

Export Citation Format

Share Document