Operating Micro Fuel Cells at a Constant Relative Humidity

2021 ◽  
Vol MA2021-02 (37) ◽  
pp. 1116-1116
Author(s):  
Nikolaj M. Bielefeld ◽  
Mikkel Jørgensen ◽  
Kristoffer S. Kure ◽  
Rasmus D. Sørensen ◽  
Torsten Berning
2015 ◽  
Vol 15 (20) ◽  
pp. 29497-29521
Author(s):  
K. Gierens ◽  
K. Eleftheratos

Abstract. Theoretical derivations are given on the change of upper-tropospheric humidity (UTH) in a warming climate. Considered view is that the atmosphere, getting moister with increasing temperatures, will retain a constant relative humidity. In the present study we show that the upper-tropospheric humidity, a weighted mean over a relative humidity profile, will change in spite of constant relative humidity. The simple reason for this is that the weighting function, that defines UTH, changes in a moister atmosphere. Through analytical calculations using observations and through radiative transfer calculations we demonstrate that two quantities that define the weighting function of UTH can change: the water vapour scale height and the peak emission altitude. Applying these changes to real profiles of relative humidity shows that absolute UTH changes typically do not exceed 1 %. If larger changes would be observed they would be an indication of climatological changes of relative humidity. As such, an increase in UTH between 1980 and 2009 in the northern midlatitudes as shown by earlier studies using HIRS data, may be an indication of an increase in relative humidity as well.


Author(s):  
Jianlu Zhang ◽  
Huamin Zhang ◽  
Jinfeng Wu ◽  
Jiujun Zhang

2019 ◽  
Vol 30 (4) ◽  
pp. 2077-2097 ◽  
Author(s):  
Zhenxiao Chen ◽  
Derek Ingham ◽  
Mohammed Ismail ◽  
Lin Ma ◽  
Kevin J. Hughes ◽  
...  

Purpose The purpose of this paper is to investigate the effects of hydrogen humidity on the performance of air-breathing proton exchange membrane (PEM) fuel cells. Design/methodology/approach An efficient mathematical model for air-breathing PEM fuel cells has been built in MATLAB. The sensitivity of the fuel cell performance to the heat transfer coefficient is investigated first. The effect of hydrogen humidity is also studied. In addition, under different hydrogen humidities, the most appropriate thickness of the gas diffusion layer (GDL) is investigated. Findings The heat transfer coefficient dictates the performance limiting mode of the air-breathing PEM fuel cell, the modelled air-breathing fuel cell is limited by the dry-out of the membrane at high current densities. The performance of the fuel cell is mainly influenced by the hydrogen humidity. Besides, an optimal cathode GDL and relatively thinner anode GDL are favoured to achieve a good performance of the fuel cell. Practical implications The current study improves the understanding of the effect of the hydrogen humidity in air-breathing fuel cells and this new model can be used to investigate different component properties in real designs. Originality/value The hydrogen relative humidity and the GDL thickness can be controlled to improve the performance of air-breathing fuel cells.


2019 ◽  
Vol 3 (1) ◽  
pp. 73-82 ◽  
Author(s):  
Serguei Lvov ◽  
Elena Chalkova ◽  
Gregory Rybka ◽  
Mark Fedkin ◽  
David Wesolowski ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document